Exemplo de preenchimento da folha "Tool 1" do Formulário para Recolha de Dados de Atividade
Tool 1 - Applicability of partial cessation rules and calculating projected adjustment factor
I
Part 1 - Tool for checking 30% / 50,000 EUA criteria
This tool helps to check for each year which of your sub-installations are to be monitored regarding the partial cessation rule (Article 23 of the CIMs).
A sub-installation is to be monitored if it contributes at least 30% of the installation's final annual amount of emission allowances allocated free of
charge, or at least 50000 allowances. In some cases this may change every year. The correct application of this criterion can be checked with this
Note that the use of this tool is optional.
Ano referente à
comunicacão dos dados
2014
(a) Relevant reporting period
Please enter here the year for which you want to assess which installations are relevant for the partial cessation rule.
Quantidade final anual de LE
gratuitas, ao nível de subinstalação
(b) Latest final allocation
Please enter here the latest final allocation. Entries here should
- take into account any significant capacity changes after 30 June 2011 approved by the competent authority following the Commission's decision pursuant to
Article 19(4) of the CIMs.
- NOT take into account any allocation adjustments due to the application of adjustment factors in accordance with Article 23 of the CIMs (partial cessations).
Sub-installation
0 Phase before start
1 Roof tiles
2
3
4
5
6
7
8
9
10
11 Heat benchmark sub-installation,
CL
12 Heat benchmark sub-installation,
non-CL
13 Fuel benchmark sub-installation, CL
14 Fuel benchmark sub-installation,
non-CL
15 Process emissions sub-installation,
CL
16 Process emissions sub-installation,
non-CL
17 Private households
Total final free allocation
2013
2014
2015
2016
2017
2018
2019
2020
20.000
20.000
20.000
20.000
20.000
20.000
20.000
20.000
10.000
10.000
10.000
10.000
10.000
10.000
10.000
10.000
8.500
8.500
8.500
8.500
8.500
8.500
8.500
8.500
38.500
38.500
38.500
38.500
38.500
38.500
38.500
38.500
(c) Result: Is the partial cessation rule applicable?
Based on your entries under point (a) and (b) above, it will be displayed here automatically for each sub-installation if the rules for partial cessations are applicable.
If the answer is "No" the sub-installation does not fulfill the 30% or the 50,000 EUA criteria for the reporting year selected under point (a) above.
Sub-installation
1 Roof tiles
2
3
4
5
6
7
8
9
10
11 Heat benchmark sub-installation, CL
12
13
14 Fuel benchmark sub-installation, non-CL
15
16
Cessation applicable?
Yes. Partial cessation rule is applicable for that year!
Nota: A subinstalação "Roof tiles deverá ser indicada no
ponto 3 da folha Procedure , por ser necessário a
avaliação de uma situação de cessação parcial
No. Partial cessation rule is not applicable for that year!
No. Partial cessation rule is not applicable for that year!
1/2
Exemplo de preenchimento da folha "Tool 1" do Formulário para Recolha de Dados de Atividade
II
Part 2 - Tool for calculating the projected activity level and adjustment factor
This tool helps to extrapolate activity level values from an earlier date to the full annual value.
Note that the use of this tool is optional.
(a) Use sub-installations from tool 1 part 1?
Se for selecionado "Falso"
será necessário a indicação
das sub-instalações na
alínea b)
VERDADEIRO
Please enter here if you want to use this tool proceeding with the sub-installations identified under part 1 of the tool above.
If you enter "FALSE", you have tomannually enter relevant sub-installations to be monitored under point (b) below.
(b) Select sub-installations for this tool manually
Please enter here the relevant sub-installations in case you have not used part 1 of this tool, or if you have chosen not to proceed with the sub-installations identified under part 1
of the tool, i.e. you have chosen "FALSE" under point (a) above.
Product BM sub-installations:
Fall-back BM sub-installations:
Deverá ser inserida a data (dia e mês) correspondente
ao nível (s) de atividade(s), a ser apresentado (s) na
coluna AL da tabela da alínea d). No mínimo deverão
ser introduzidos dados até 30 de novembro, por
forma a garantir uma maior representatividade dos
mesmos.
(c) Date of calculation (for preliminary reporting):
The date entered here will allow calculation of the projected activity levels under point (d) below.
It may be the same date as the deadline set by the CA displayed in sheet "Procedure" point 5(a).
Date in the current reporting year until which data is already available:
Day
30
Month
11
Date
domingo, 30 de novembro de 2014
(d) (Projected) Activity levels and adjustment factors
In this section for each sub-installation being monitored the projected activity level for the total calendar year and the projected adjustment factor in accordance with Article 23 of
the CIMs are determined.
Please note that the result here is just a projection under the assumption that the average daily activity level will also be relevant for the days remaining in the
calendar year. Therefore, this section can just be seen as a supporting tool.
Any projected or expected changes of the adjustment factor applied for the current reporting year has to be submitted to the CA by the date specified in section
5(a) of the "procedure" sheet, if such date is specified in your Member State. In any event the final value for 31 December must be reported without undue delay
using the NE&C template (or your Member State's appropriate template for this purpose), if a change is found.
Please enter here for each sub-installation for which the partial cessation rule is applicable, the initial and the current activity level (AL).
The initial activity level is the activity level used by the Competent Authority for allocation (i.e. the activity level used in the NIMs plus all accumulated capacity changes from
approved allocation changes due to significant capacity changes). If your installation has had such capacity changes, you can take the changes in activity levels from the field
"AL new/added/reduced" in sheet K_summary of the relevant NE&C templates.
The current activity level entered should relate to the period from the beginning of the calendar year
the date provided under point (c) above.
Tem until
de estar
In cases of more complex calculation of the activity level (in particular if the heat tool is requiredcoerente
or the special
com arules of Annexes II and III of the CIMs apply to product
benchmarks) tools 2A to 2D may be used and the resulting activity levels obtained can be entered
the corresponding
"current AL" column.
data into
da alinea
c)
If part 1 of this tool has been used and you have chosen "TRUE" under point (a) above, the sub-installations from part 1 of this tool will be automatically taken from there.
Sub-installation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Roof tiles
Unit
Initial AL
Current AL
(year so far)
Projected
AL (year)
Projected
AL (year)
Result:
Projected adjustment
tonnes /
year
120
60
66
55%
1,00
Nível histórico de atividade
(historical activity level)
constante da folha K do
Formulário NIMs
2/2
Nível
atividade
contabilizado
pelo operador
de 01/01 até
30/11
Cálculo
efetuado
pelo
formulário
- nível
atividade
anual (de
01/01 até
31 /12
% do
nivel de
atividade
anual face
ao inical
AL
Para este exemplo o
fator de ajustamente
face à quantidade de
LE a título gratuito é
de 1,00, pelo que
não se verifica uma
situação de cessação
parcial
Download