III Curso Nacional de Ventilação Mecânica São Paulo, 2008 Interferência da interface na performance da VNI Marcelo Alcantara Holanda Prof Adjunto, Terapia Intensiva/Pneumologia Universidade Federal do Ceará UTI respiratória do Hospital de Messejana, Fortaleza www.huwc.ufc.br Há várias maneiras de se fazer VNI Fatores decisivos para se tentar VNI com maiores chances de sucesso: • Interesse no método • Trabalho em equipe • Conhecimento • Equipamentos: – Ventiladores – Interfaces – Monitorização • Local: – – – – – UTI Semi-intensiva Emergência Enfermaria Domicílio VNI – Importância da interface • Índices de falha da VNI podem chegar a 40 a 60% • Problemas relacionados a interface: 50 a 100% • Má tolerância a VNI devido a problemas no binômio máscara-paciente: 25 a 33% Hill NS. Complications of Noninvasive Positive Pressure Ventilation. Resp Care 1997 Schettino G, Altobelli N, Kacmarek, RM. Critical Care Med 2008 Soo Hoo GW, Santiago S, Williams AJ. Crit Care Med 1994 VNI – Problemas mais comuns com a interface •Vazamentos desconfortáveis: Olhos Boca • Dor em pontos de contato • Escara na face • Ressecamento de mucosa • Re-inalação de CO2 • Claustrofobia Hill NS. Complications of Noninvasive Positive Pressure Ventilation. Resp Care 1997 Liesching T, Kwok H, Hill N. Acute Applications of Noninvasive Positive Pressure Ventilation. Chest 2003 A VNI tem muitas vantagens E também muitas limitações... Holanda, MA e col. J Pneumol, 2001 A VNI foi eficiente em 2/3 das vezes (37/60, 62%). • Os seguintes fatores se associaram à falha: - Apache II mais elevado: 30,4+9 vs 22,2+8, p=0,001 - Menor eficiência em a f respiratória, e em o pH - Uso de níveis mais baixos de IPAP Má interação – vazamentos – desconforto? - Mortalidade: 0 no GS vs (10, 43%) nos casos de falha VNI – Problemas no estudo das interfaces •Novas interfaces são continuamente desenvolvidas e lançadas no mercado: - Novas máscaras nasais e faciais - Máscara facial total - Helmet • As máscaras raramente são comparadas de forma sistemática em ensaios experimentais ou clínicos • Ventilador mecânico, ajustes e modos ventilatórios podem interferir no desempenho das máscaras VNI – Estudo da performance de interfaces • Estudos in vitro – modelos mecânicos • Estudos em voluntários sadios ou pacientes estáveis • Estudos no cenário clínico de IRA VNI – Estudo da performance de interfaces • Estudos in vitro – modelos mecânicos • Estudos em voluntários sadios ou pacientes estáveis • Estudos no cenário clínico de IRA Schettino G et al. Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure, Crit Care Med 2003 Schettino G et al. Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure, Crit Care Med 2003 Relevância clínica? VNI – Estudo da performance de interfaces • Estudos in vitro – modelos mecânicos • Estudos em voluntários sadios ou pacientes estáveis • Estudos no cenário clínico de IRA • 12 voluntários sadios • Medida de pressão nos pontos de contato da máscara com a face CPAP 5cmH2O CPAP 10cmH2O Holanda MA et al. Comparison of the total face to facial and nasal masks on short-term adverse events during noninvasive ventilation. • Randomized, crossover trial in 24 healthy volunteers A1 B1 C1 A2 B2 C2 Figure 1. The three types of NIV masks fixed in a volunteer head by their respective straps in frontal and lateral views. A1 and A2: Total face (TFM); B1 and B2: Facial (FM); C1 and C2: Nasal (NM). One peculiarity of each mask is shown. Black arrow: built-in exhalation port of the TFM. White arrow: middle up strap of the FM. White arrowhead: foam forehead spacer of the NM. Holanda MA et al. Comparison of the total face to facial and nasal masks on short-term adverse events during noninvasive ventilation. Mask randomization: Nasal, Facial or Total Face IPAP: 11 / EPAP: 6cmH2O (Adaptation – 5 to 10 minutes) (LoP-5 minutes) Adverse events questionnaire*/ VAS comfort* (RR, SpO2, EtCO2, Pressure and Flow curves) IPAP: 15 / EPAP 10cmH2O (Adaptation – 5 to 10 minutes) (MoHiP-5 minutes) Adverse events questionnaire* / VAS comfort* (RR, SpO2, EtCO2, Pressure and Flow curves) Washout period of 10 minutes for next mask trial Figure 2. Study design. RR - respiratory rate, EtCO2- end tidal CO2, SpO2 - pulse oxymetry VAS - Visual Analogical Scale LoP: Low pressure, MoHiP: Moderate to high pressure * while in use of the mask; solid arrow: study period Mean Short-Term Adverse Events score (0 to 3) Holanda MA et al. Comparison of the total face to facial and nasal masks on short-term adverse events during noninvasive ventilation. NM FM TFM 1,4 ** ¶ ¶ §§ 1,2 1 § § 0,8 ++ § *§ 0,6 0,4 0,2 ¶ ** * 0 LoP MoHiP Pain LoP MoHiP Unpleasant air leak LoP MoHiP Oronasal dryness Figure 3. Scores for three categories of STAE: 1. Pain (forehead, nose bridge, cheeks and chin), 2. unpleasant air leaks (around the eyes and mouth) and 3. oronasal dryness (nasal and oral or throat) during NIV trial according to mask type and pressure setup. Data shown as mean and standard error of the mean. LoP: Low pressure, MoHiP: Moderate to high pressure. Holanda MA et al. Comparison of the total face to facial and nasal masks on short-term adverse events during noninvasive ventilation. • Re-Inalação de CO2 CO2 – EPAP > 4cmH2O previne EtCO2 no circuito: Total face: 0 CO2 CO2 CO2 CO2 CO2 Incidence (%) of specific short-term adverse events according to mask type and pressure setup (n=24) Type of STAE 1. Pain at the forehead 2. Pain at nose bridge 3. Pain in the cheeks 4. Pain in the chin 5. Air leaks around the eyes 6. Air leaks around the mouth 7. Dry mouth or throat 8. Dry or congested nose 9. Pressure from the mask 10. Skin irritation 11. Claustrophobia Pressure setup Nasal mask % Facial mask % Total face mask % LoP 20.8 25 16.7 MoHiP 29.2 37.5 25 LoP 37.5++ 45.8§§ 4.2 MoHiP 41.7+ 50§§ 8.3 LoP 12.5 41.7¶ 25 MoHiP 20.8 41.7 37.5 LoP NA 12.5 25 MoHiP NA 29.2* 29.2 LoP 58.3 50 41.6 MoHiP 58.3 70.8* 54.2 LoP 16.7 41.7§§ 8.3 MoHiP 33.3+ 54.2¶§§ 8.3 LoP 16.7 62.5¶¶ 66.7++ MoHiP 33.3* 62.5¶¶ 75++ LoP 16.7 12.5 29.2+ MoHiP 37.5* 20.8 29.2 LoP 54.2 66.7 66.7 MoHiP 62.5 70.8 75 LoP 37.5 25 25 MoHiP 37.5 25 29.2 LoP 8.3 20.8 33.3+ MoHiP 8.3 20.8 33.3+ Holanda MA, Reis RC, Winkeler, GFP, Fortaleza SCB, Pereira EDB Holanda MA et al. Comparison of the total face to facial and nasal masks during noninvasive ventilation. Sob revisão para publicação Nasal Efeitos adversos por paciente Facial Facial Total + ++ ++ Vazamentos ++ ++ + Dor ++ +++ + Ressecamentos + ++ +++ Conforto global ++ ++ ++ CO2 exalado no circuito ++ + - Máscara Nasal • Vantagens – Menos claustrofobia – Possibilita fala, deglutição – Campo de visão favorável • Aplicações – Pacientes Colaborativos – Não respiram pela boca – Necessidade de baixos níveis de pressão Máscara Facial (oronasal) • Vantagens – Maior pressurização – Aplicável em respiradores bucais – Menor necessidade de cooperação • Desvantagens - Mais desconfortável - Claustrofobia - Vazamentos: olhos e boca Máscara Facial Total • Vantagens – Eficaz em pacientes com: – Dificuldade de adaptação – Ansiosos – Com lesão no dorso do nariz – Com necessidade de altas pressões – Intervenção Aguda • Recursos e Benefícios – Confortável – Rápida Instalação – Rápida retirada (tira vermelha) – 2 portas adicionais para eliminação de CO2 • Desvantagens: • - Não funciona bem em ventiladores convencionais (fuga aérea alta) Boas práticas em VNI • Checar tamanho da máscara • Usar tecido artificial – RestoreTM, Granuflex® ou Duoderm® • Tipos de Interface • Vazamento não intencional* – – – – 0 a 6 L/min – muito justa 7 a 25 L/min – OK 26 a 60 L/min – Folgada > 60L/min – Atenção! Necrose tecidual causada por um mal ajuste da máscara Sistema Helmet Melhor tolerância que F em estudo piloto. Antonelli et al Crit Care Med 2002 Pressões positivas não parecem afetar membrana timpânica. Cavaliere et al Intensive Care Med 2003 Esquinas A, Murcia, Espanha com permissão Interfaces: eficiência Máscara Corrigir hipercapnia Nasal Facial Facial Total Helmet + ++ ++ ++ ++ ++ ++ ++ ++ +++ ++ +++ Evitar Vazamentos Desconfortáveis + ++ ++++ ++++ Patência de vias aéreas + ++ ++ ++ Acomodar altas pressões vvaa + ++ Reverter hipóxia Evitar reinalação de CO2 +++ +++ VNI – Estudo da performance de interfaces • Estudos no cenário clínico de IRA 70 pacientes em IRA 35 máscaras F vs 35 Nasal Estudo retrospectivo de 13 episódios de IRA, 10 pacientes que não toleraram máscara N ou F VNI com a MFT 8 - IRA hipercápnnica 2 – IRA hipoxêmica 2 intubações por hipersecreção Cuidados 1 na instalação da VNI, atenção 2 à interface 4 3 5 2 casos de intolerância a máscara em 458 episódios! Um dia haverá uma interface de VNI especial para você, mas até lá...