CZ0265/CZ0266
IP66/67
LUMINÁRIA DE SEGURANÇA AUMENTADA COM OU SEM EMERGÊNCIA
FULL PLASTIC INCREASED SAFETY LIGHT FIXTURE WITH OR WITHOUT EMERGENCY
CERTIFICADO / CERTIFICATE: MC, AEX-9030
LUMINÁRIA DE SEGURANÇA AUMENTADA COM OU SEM EMERGÊNCIA PARA LÂMPADAS FLUORESCENTES
FULL PLASTIC INCREASED SAFETY LIGHT FIXTURE WITH OR WITHOUT EMERGENCY FOR FLUORESCENT LAMPS
Dados técnicos principais:
E.O.L. Protection
40
20
0
100
60
A
B
B
80
A
140
45
160
5
5
31
31
120
140
160
A B
100
120
180
180
200
200
0
21.5
55
A
580 (2x 14/18/20W)
1335 (2x 28/36/40W)
70
º
D
B 90
A0
A0
A0
SISTEMA DE FIXAÇÃO 4
SYSTEM OF FIXATION 4
B 90
B 90
SUPORTE AJUSTÁVEL PARA
FIXAÇÃO EM PAREDE
SUPPORT ADJUSTABLE FOR
FIXATION IN WALL
725 (2x 14/18/20W)
1335 (2x 28/36/40W)
400 (2x 14/18/20W)
800 (2x 28/36/40W)
E
119
30º
60º
222
145
H
T
LUMINÁRIA / LIGHT FITTING
MODELO / MODEL
1 - 1 REATOR / BALLAST
2 - 2 REATORES / BALLAST
1 - 01 LÂMPADA / LAMP
2 - 02 LÂMPADAS / LAMPS
F
G
Especificações:
Specifications:
TOTAL Ex
B
C
Dimensões externas em (mm):
Outline dimensions (mm):
2~M8
Nut M8
0
B 90
A0
GRAMPO DE FIXAÇÃO EM POSTE
DE 11/4" a 11/2" E POSTE DE 2”
STAPLE OF FIXATION
IN POST FROM 11/4 " TO 11/2 "
AND POST OF 2”
4~Φ7
45
80
SISTEMA DE FIXAÇÃO 3
SYSTEM OF FIXATION 3
40
60
A
77
SUPORTE PARA MONTAGEM
PENDENTE
SUPPORT FOR PENDING
ASSEMBLY
20
40
B
70
SISTEMA DE FIXAÇÃO 2
SYSTEM OF FIXATION 2
90
90
270
270
0
10
PEÇA DOBRADA / BEND PIECE
l(cd/1000 lm)
20
4~Φ9
55
200
110
90
SUPORTE DE FIXAÇÃO PARA
MONTAGEM NO TETO
SUPPORT OF FIXATION FOR
ASSEMBLY IN THE ROOF
Curva fotométrica:
Luminous intensity distribution curve:
l(cd/1000 lm)
21
SISTEMA DE FIXAÇÃO 1
SYSTEM OF FIXATION 1
110
BR-Ex d e IIC T4/T5;
BR-Ex ed IIC T4/T5;
1, 2, 21 e 22;
1, 2, 21 and 22;
IP66/67;
IP66/67;
Fluorescente tubular (FL);
Fluorescent tube (FL);
1x ou 2x 14/18/20/28/36/40W;
1x ou 2x 14/18/20/28/36/40W;
127V, 220V ou 90V à 240V + 10%
127V, 220V or 90V ~ 240V + 10%;
50/60Hz;
50/60Hz;
G13;
G13 two-pin lamp tube;
E.O.L. Protection, Fator de potência > 0,98;
E.O.L. Protection, Power factor > 0,98;
De 1,5h à 3h;
1,5h up to 3h;
2 x1,5mm2 ;
2 x 2,5mm2 ;
M25 x 1,5mm2;
M25 x 2,5mm2;
NBR IEC 60079-0, NBR IEC 60079-7 e
NBR IEC 60529;
NBR IEC 60079-0, NBR IEC 60079-7 and
NBR IEC 60529.
165
Marcação:
Ex mark:
Zonas:
Zones:
Grau de proteção:
Degree protection:
Lâmpada: Lamp:
Potência:
Potency:
Voltagem:
Rated Voltage:
Frequqência:
Frequency:
Soquete:
Hold lamp:
Reator: Ballast:
Emergência:
Emergency:
Terminais:
Terminals:
Entrada de cabos:
Cable entry:
Normas aplicáveis:
Standards:
L
265
2
2
1
2
S
S1
I
S1 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 1
S2 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 2
S3 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 3
S4 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 4
J
E - COM EMERGÊNCIA / WITH EMERGENCY
S - SEM EMERGÊNCIA / WITHOUT EMERGENCY
1 - 127V
2 - 220V
9 - 90 à 240V
1 - 14W
2 - 18/20W
4 - 36/40W
8 - 28W
Endereço/Adress: Rod. Campos Vitória KM 46 - Travessão 7º Distrito de Campos - RJ | Tel.: +55 (22) 2748.1200 - Website: http://www.totalex.com.br - [email protected]
G02
CZ0865/CZ0866
IP66/67
LUMINÁRIA DE SEGURANÇA AUMENTADA COM OU SEM EMERGÊNCIA
FULL PLASTIC INCREASED SAFETY LIGHT FIXTURE WITH OR WITHOUT EMERGENCY
CERTIFICADO / CERTIFICATE: MC, AEX-9030
LUMINÁRIA DE SEGURANÇA AUMENTADA COM OU SEM EMERGÊNCIA PARA LÂMPADADS FLUORESCENTES
FULL PLASTIC INCREASED SAFETY LIGHT FIXTURE WITH OR WITHOUT EMERGENCY FOR FLUORESCENT LAMPS
E.O.L. Protection
Dados técnicos principais:
Curva fotométrica:
Luminous intensity distribution curve:
l(cd/1000 lm)
40
20
40
60
60
80
100
A
B
B
140
45
180
180
200
200
21.5
GRAMPO DE FIXAÇÃO EM POSTE
DE 11/4" a 11/2" E POSTE DE 2”
STAPLE OF FIXATION
IN POST FROM 11/4 " TO 11/2 "
AND POST OF 2”
90
160
5
160
5
31
31
120
140
Nut M8
580 (2x 14/18/20W)
1335 (2x 28/36/40W)
70
º
0
B 90
A0
A0
A0
SISTEMA DE FIXAÇÃO 4
SYSTEM OF FIXATION 4
B 90
B 90
Dimensões externas em (mm):
Outline dimensions (mm):
SUPORTE AJUSTÁVEL PARA
FIXAÇÃO EM PAREDE
SUPPORT ADJUSTABLE FOR
FIXATION IN WALL
725 (2x 14/18/20W)
1335 (2x 28/36/40W)
400 (2x 14/18/20W)
800 (2x 28/36/40W)
119
30º
60º
145
222
Especificações:
Specifications:
T
TOTAL Ex
LUMINÁRIA / LIGHT FITTING
MODELO / MODEL
1 - 1 REATOR / BALLAST
2 - 2 REATORES / BALLAST
1 - 01 LÂMPADA / LAMP
2 - 02 LÂMPADAS / LAMPS
G03
55
SUPORTE PARA MONTAGEM
PENDENTE
SUPPORT FOR PENDING
ASSEMBLY
4~Φ7
A B
100
120
I
J
80
A
B 90
2~M8
77
45
90
20
40
0
F
H
0
20
A0
G
270
270
A
70
SISTEMA DE FIXAÇÃO 2
SYSTEM OF FIXATION 2
l(cd/1000 lm)
0
D
E
10
PEÇA DOBRADA / BEND PIECE
SISTEMA DE FIXAÇÃO 3
SYSTEM OF FIXATION 3
B
C
4~Φ9
55
200
110
90
SUPORTE DE FIXAÇÃO PARA
MONTAGEM NO TETO
SUPPORT OF FIXATION FOR
ASSEMBLY IN THE ROOF
A
B
21
SISTEMA DE FIXAÇÃO 1
SYSTEM OF FIXATION 1
110
BR-Ex d e IIC T4/T5;
BR-Ex ed IIC T4/T5;
1, 2, 21 e 22;
1, 2, 21 and 22;
IP66/67;
IP66/67;
Fluorescente tubular (FL);
Fluorescent tube (FL);
1x ou 2x 14/18/20/28/36/40W;
1x or 2x 14/18/20/28/36/40W;
127Vca, 220Vca ou 90Vca à 240Vca + 10%
127Vac, 220Vac or 90Vac ~ 240Vac + 10%;
50/60Hz;
50/60Hz;
G13;
G13 two-pin lamp tube;
2 x1,5mm2 ;
2 x 2,5mm2 ;
Proteção E.O.L. / > 0,98;
E.O.L. Protection / > 0,98;
De 1,5h à 3h;
1,5h up to 3h;
M25 x 1,5mm2;
M25 x 2,5mm2;
NBR IEC 60079-0, NBR IEC 60079-7 e
NBR IEC 60529;
NBR IEC 60079-0, NBR IEC 60079-7 and
NBR IEC 60529.
165
Marcação:
Ex mark:
Zonas:
Zones:
Grau de proteção:
Degree protection:
Lâmpada: Lamp:
Potência:
Potency:
Voltagem:
Rated Voltage:
Frequqência:
Frequency:
Soquete:
Hold lamp:
Terminais:
Terminals:
Reator/ Fator de potência:
Ballast/ Power factor:
Emergência:
Emergency:
Entrada de cabos:
Cable entry:
Normas aplicáveis:
Standards:
L
865
1
2
2
9
E
S4
S1 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 1
S2 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 2
S3 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 3
S4 - SISTEMA DE FIXAÇÃO/SYSTEM FIXATION 4
E - COM EMERGÊNCIA / WITH EMERGENCY
S - SEM EMERGÊNCIA / WITHOUT EMERGENCY
1 - 127V
2 - 220V
9 - 90 à 240V
1 - 14W
2 - 18/20W
4 - 36/40W
8 - 28W
Endereço/Adress: Rod. Campos Vitória KM 46 - Travessão 7º Distrito de Campos - RJ | Tel.: +55 (22) 2748.1200 - Website: http://www.totalex.com.br - [email protected]
Download