SIMBOLOGIA CANALETA FIXADA NA CANALETA FIXADA NA 3.6bb,bc ARQUITETURA) ARQUITETURA) H V 3.8 3.9 3.1ab 2x32W 3.9 3.31 3.1ab 2x32W 3.8 3.1ac 2x32W 3.9 3.1ad 3.1ah 3.9 3.32 CPD OFICIAIS DE 3.1ah 2x16W 3.1af 2x32W D 3.8 3.1ac 2x32W 3.9 3.9 3.1aa 2x32W 3.1aa 2x32W 3.8 3.12 3.10 3.8 3.10 3.1aa,ab A 3.1ac 2x32W B 3.1ac S W 3.13 TOMADA A SER ALIMENTADA VIA NO-BREAK PARA O PABX 3.14 3.1ag 2x32W L L 3.24 K J 3.5az 2x32W 3.10 3.3am 2x32W 3.5az 2x32W 3.5az 2x32W 3.5ba 2x32W 3.5ba 2x32W 3.6bc 2x32W 3.6bc 2x32W CANALETA FIXADA NO 3.6bb,bc 3.24 3.10 3.1ae F 3.1af,ag 3.10 QDC-3P 3.11 3.4al 2x32W 3.3aj 2x16W X 3.6bd 2x32W 3.6bb 2x32W 3.6bb 2x32W 3.20 QDC-3P 3.5az 2x32W Q 3.5az 2x32W 3.5az 2x32W 3.5ba 2x32W 3.28 3.5ba 2x32W 3.29 3.6bd 2x32W 3.22 3.6bb,bc 3.6bb 2x32W 3.29 3.6bb,bc 3.22 3.6bb 2x32W 3.26 3.26 QI-3P 3.3bj 3.21 3.3bj 50W 3.3ar 3.7bh 2x16W 3.3aw 3.3bj 3.5az 2x32W 3.4ax 2x32W 3.19 3.5az 2x32W 3.5az 2x32W 3.5ba 2x32W 3.5ba 2x32W 3.7bh 2x32W 3.7bi 2x32W 3.7bg 3.7bg 3.22 3.19 I.S.DEF. 2x16W 3.2at 2x32W 3.19 3.4ax 2x32W 3.4ax 2x32W 3.7bi,bh 3.22 3.7bg 2x32W SECRETARIA 3.2au 1aa 3.30 3.19 3.3bj 3.2ap,aq 3.2as 2x32W 3.26 3.4ax,ay 3.3aw,bj 3.17 3.2as 2x32W 3.26 3.26 3.4ax,ay 3.3aw 3.17 3.3ar 2x16W 3.6bb 2x32W 3.27 1,25KVA 3.3am 2x32W 3.20 3.2as,at 3.6bb 2x32W 3.30 3.12 3.11 3.21 QUADRO DE INTERRUPTORES CIRCUITO 3.3 COMANDOS: am,an,ao,az,ba 3.2ap 2x32W INTERRUPTOR BIPOLAR 2P 20A-250V, INSTALADO A 120cm DO PISO ACABADO, EM ALINHAMENTO VERTICAL COM A TOMADA. 3.6bb,bc 3.30 3.3ai Y 3.11 IS 3.2ap 2x32W 3.25 3.22 3.6bd 3.3an 2x32W 3.21 3.16 1,25KVA 3.25 3.6bd 3.26 3.3ao 2x16W ACABADO EM DOIS CONDULETES MULTIPLOS, SENDO UM CONDULETE PARA CADA R 3.3an 2x32W CELA 3.6bc 2x32W 3.25 3.22 DESCE P/ O QGBT 3.15 3.15 ACABADO EM DOIS CONDULETES MULTIPLOS, SENDO UM CONDULETE PARA CADA 3.25 3.6bd 2x32W 3.3am,an,ao 5az,ba 3.3an 2x32W 3.24 I 3.4al 2x32W 3.4al 2x32W 3.11 3.3aj E M 3.24 3.1ag 2x32W G C 3.24 3.25 3.3ai 2x32W 3.1ae 2x32W TOMADA A SER ALIMENTADA VIA NO-BREAK PARA A CENTRAL DE ALARME M 3.25 ASSISTENTE SOCIAL 3.1ae 2x32W 3.23 N 3.4al DEP. ARMAS 3.12 3.8 O T 3.1af 2x32W CENTRAL DE ALARME 3.1aa 2x32W 3.24 3.28 3.12 3.23 3.1ad 2x32W ASSESSORIA IS 3.33 3.11 3.1ae 2x32W P 3.11 3.9 3.9 3.1aa 2x32W U UMA TOMADA ALTA CONFORME NBR-14.136 250V/20A INSTALADA EM CAIXA DE PVC 4x2" DE IS 3.4ax 2x32W 3.2au ELETRODUTO DE FERRO GALVANIZADO A FOGO DO TIPO PESADO (NBR-13057) INSTALADO 3.3ao 2x16W 3.2ap 2x32W 3.2ap 2x32W 3.2aq 2x32W 3.2as 2x32W 3.15 3.3ao 2x16W 3.2as 2x32W 3.2at 2x32W 3.18 1,25KVA 3.15 IS 3.17 3.17 3.34 3.2au 2x16W 3.35 3.2av 3.2av 3.5az 2x32W IS 3.5az 2x32W 3.5az 2x32W 3.5ba 2x32W 3.5ba 2x32W 3.7bh 2x32W 3.19 3.4ay 2x32W 3.2av 2x16W 3.30 3.19 3.4ay 2x32W 3.7bi 2x32W 3.7bi ELETRODUTO DE FERRO GALVANIZADO A FOGO DO TIPO PESADO (NBR-13057) INSTALADO 3.7bf 3.7bh 3.7be 3.30 3.23 3.7bh 3.7bi 3.23 3.7be 2x16W CANALETA EM PVC COM SEPTO (DUAS VIAS), NA COR BRANCA, INSTALADA A 30cm DO PISO 3.7bf 2x16W 3.23 CANALETA FIXADA PAVIMENTO ARQUITETURA) INCORPORADOS INTERNAMENTE AO PROJETOR, DISPOSITIVO DE FECHAMENTO ESCALA: .......................................................... 1/50 EQUIPAMENTOS AUXILIARES PELA ABERTURA FRONTAL DA LENTE DE VIDRO, PERCURSOS DE CABOS: A GRELHA. B C NOTAS GERAIS: D E "220V". F G H 6 - TODOS OS ELETRODUTOS OU TRECHOS DE ELETRODUTOS APARENTES OU NO INTERIOR DE GALVANIZADO DO TIPO PESADO, CONFORME NBR 13.057. I CIRCUITO XX XXXVA J XX XXXVA XX XXXVA K F ADESIVA PAREDE DA ELETROCALHA BUCHA TOMADA EM VA TIPO "D" CHUMBADOR CBA N ELETRODUTO ELETROCALHA. T ARRUELA L ELETRODUTO DE F N T BUCHA E ARRUELA GALVANIZADO M ELETROCALHA LISA COM TAMPA FASE: PRETO - NEUTRO: AZUL CLARO - TERRA: VERDE - RETORNO: BRANCO - RETORNO PARALELO: CINZA. ALARME PNE ELETRODUTO DE ELETRODUTO DE N F ATIRANTADAS) NA LAJE. R O SEM ESCALA SEM ESCALA - SUPORTAR A CADA 1,50m CONDULETE P SEM ESCALA COM TAMPA Q R ELETRODUTO NA ELETROCALHA S SEM ESCALA 14 - O MEMORIAL DESCRITIVO E QUANTITATIVO FAZEM PARTES INTEGRANTES DESTE PROJETO, E 100 T FIXADOS SOBRE A PAREDE COM CAIXA DE PASSAGEM EM PVC DE SOBREPOR 200x200x100mm PARA A PASSAGEM DOS CABOS V PAREDE A UMA ALTURA DE 30,0cm DO PISO ACABADO 100 U PROJETO) TIPO "CBA" LAJE PASSAGEM DOS CABOS DE DADOS / VOZ E ALARME PASSAGEM DOS CABOS ELETRICOS (CIRCUITOS DE W SUPORTE DE EQUIPAMENTOS EM CAIXA ALTA NA COR BRANCA COM (DUTO DUPLO) FIXADO NA PAREDE PARA A CABEAMENTO ESTRUTURADO 50 300 PT-XX-NN PT-XX-NN 38 VER PLANTA INSTALADO SOBRE O DUTO EM PVC XX XXXVA 73 XX XXXVA VISTA LATERAL DA CANALETA 2150 TIPO "CBA" 100 2200 DUTO EM PVC COM TAMPA NA COR BRANCA PASSAGEM DOS CABOS ELETRICOS (CIRCUITOS DE AR-CONDICIONADO) REV.02 14/08/2012 BRENO REV.01 17/07/2012 BRENO REV.00 04/05/2012 BRENO OCORR. DATA RESP. PROJETO EXECUTIVO PARA: ELETROCALHA 200mm: UTILIZAR 19 SOBRE O DUTO EM PVC Y 250 SUPORTE DE EQUIPAMENTOS EM CAIXA X 2"x1/4" PARAFUSO M6 COM PORCA, ARRUELA LISA E ARRUELA PROJETO) PERFILADO PERFURADO 38x19mm PARA VER PLANTA PARAFUSO M6 COM PORCA, ARRUELA LISA E ARRUELA DE ELETROCALHA 300mm: UTILIZAR TJMG DUTO EM PVC NAS 2 - ESQUEMA DE ATERRAMENTO ADOTADO: TN-S. COMO BD-3. SEM ESCALA SEM ESCALA 4 - TEMPERATURAS CONSIDERARADAS EM PROJETO: ESTADO DE MINAS GERAIS SEM ESCALA CENTRO PROJETO REFORMA 60.669-1; ABNT NBR 14.136; - DISJUNTORES ACIMA DE 125A (CAIXA MOLDADA): ABNT NBR IEC 60.947-2; PROJETO EXECUTIVO D - DISPOSITIVOS DIFERENCIAL RESIDUAL (DR): ABNT NBR NM 61.008; - DISPOSITIVOS PROTETORES DE SURTOS (DPS): NBR IEC 61.643-1; - DUTOS CORRUGADOS DE POLIETILENO (PE) PARA INFRAESTRUTURAS DE ENERGIA E 14/08/2012 ABNT NBR 10.898; Av. Augusto de Lima, 655, cj. 418 Centro - Belo Horizonte/MG Telefax: (31) 3324-2702 http://www.viabile.com.br [email protected] SIMBOLOGIA, NOTAS GERAIS DETALHES CONSTRUTIVOS abrasip-mg FORMATO INTERNACIONAL A0 (1189 x 841mm) BRENO ASSIS 02/04