SIMBOLOGIA
CANALETA FIXADA NA
CANALETA FIXADA NA
3.6bb,bc
ARQUITETURA)
ARQUITETURA)
H
V
3.8
3.9
3.1ab
2x32W
3.9
3.31
3.1ab
2x32W
3.8
3.1ac
2x32W
3.9
3.1ad
3.1ah
3.9
3.32
CPD
OFICIAIS DE
3.1ah
2x16W
3.1af
2x32W
D
3.8
3.1ac
2x32W
3.9
3.9
3.1aa
2x32W
3.1aa
2x32W
3.8
3.12
3.10
3.8
3.10
3.1aa,ab
A
3.1ac
2x32W
B
3.1ac
S
W
3.13
TOMADA A SER
ALIMENTADA VIA
NO-BREAK PARA O
PABX
3.14
3.1ag
2x32W
L
L
3.24
K
J
3.5az
2x32W
3.10
3.3am
2x32W
3.5az
2x32W
3.5az
2x32W
3.5ba
2x32W
3.5ba
2x32W
3.6bc
2x32W
3.6bc
2x32W
CANALETA FIXADA NO
3.6bb,bc
3.24
3.10
3.1ae
F
3.1af,ag
3.10
QDC-3P
3.11
3.4al
2x32W
3.3aj
2x16W
X
3.6bd
2x32W
3.6bb
2x32W
3.6bb
2x32W
3.20
QDC-3P
3.5az
2x32W
Q
3.5az
2x32W
3.5az
2x32W
3.5ba
2x32W
3.28
3.5ba
2x32W
3.29
3.6bd
2x32W
3.22
3.6bb,bc
3.6bb
2x32W
3.29
3.6bb,bc
3.22
3.6bb
2x32W
3.26
3.26
QI-3P 3.3bj
3.21
3.3bj
50W
3.3ar
3.7bh
2x16W
3.3aw 3.3bj
3.5az
2x32W
3.4ax
2x32W
3.19
3.5az
2x32W
3.5az
2x32W
3.5ba
2x32W
3.5ba
2x32W
3.7bh
2x32W
3.7bi
2x32W
3.7bg
3.7bg
3.22
3.19
I.S.DEF. 2x16W
3.2at
2x32W
3.19
3.4ax
2x32W
3.4ax
2x32W
3.7bi,bh
3.22
3.7bg
2x32W
SECRETARIA
3.2au
1aa
3.30
3.19
3.3bj
3.2ap,aq
3.2as
2x32W
3.26
3.4ax,ay
3.3aw,bj
3.17
3.2as
2x32W
3.26
3.26
3.4ax,ay
3.3aw
3.17
3.3ar
2x16W
3.6bb
2x32W
3.27
1,25KVA
3.3am
2x32W
3.20
3.2as,at
3.6bb
2x32W
3.30
3.12
3.11
3.21
QUADRO DE INTERRUPTORES
CIRCUITO 3.3
COMANDOS: am,an,ao,az,ba
3.2ap
2x32W
INTERRUPTOR BIPOLAR 2P 20A-250V, INSTALADO A 120cm DO PISO ACABADO, EM
ALINHAMENTO VERTICAL COM A TOMADA.
3.6bb,bc
3.30
3.3ai
Y
3.11
IS
3.2ap
2x32W
3.25
3.22
3.6bd
3.3an
2x32W
3.21
3.16
1,25KVA
3.25
3.6bd
3.26
3.3ao
2x16W
ACABADO EM DOIS CONDULETES MULTIPLOS, SENDO UM CONDULETE PARA CADA
R
3.3an
2x32W
CELA
3.6bc
2x32W
3.25
3.22
DESCE P/ O QGBT
3.15
3.15
ACABADO EM DOIS CONDULETES MULTIPLOS, SENDO UM CONDULETE PARA CADA
3.25
3.6bd
2x32W
3.3am,an,ao 5az,ba
3.3an
2x32W
3.24
I
3.4al
2x32W
3.4al
2x32W
3.11
3.3aj
E
M
3.24
3.1ag
2x32W
G
C
3.24
3.25
3.3ai
2x32W
3.1ae
2x32W
TOMADA A SER
ALIMENTADA VIA
NO-BREAK PARA A
CENTRAL DE
ALARME
M
3.25
ASSISTENTE SOCIAL
3.1ae
2x32W
3.23
N
3.4al
DEP.
ARMAS
3.12
3.8
O
T
3.1af
2x32W
CENTRAL
DE ALARME
3.1aa
2x32W
3.24
3.28
3.12
3.23
3.1ad
2x32W
ASSESSORIA
IS
3.33
3.11
3.1ae
2x32W
P
3.11
3.9
3.9
3.1aa
2x32W
U
UMA TOMADA ALTA CONFORME NBR-14.136 250V/20A INSTALADA EM CAIXA DE PVC 4x2" DE
IS
3.4ax
2x32W
3.2au
ELETRODUTO DE FERRO GALVANIZADO A FOGO DO TIPO PESADO (NBR-13057) INSTALADO
3.3ao
2x16W
3.2ap
2x32W
3.2ap
2x32W
3.2aq
2x32W
3.2as
2x32W
3.15
3.3ao
2x16W
3.2as
2x32W
3.2at
2x32W
3.18
1,25KVA
3.15
IS
3.17
3.17
3.34
3.2au
2x16W
3.35
3.2av
3.2av
3.5az
2x32W
IS
3.5az
2x32W
3.5az
2x32W
3.5ba
2x32W
3.5ba
2x32W
3.7bh
2x32W
3.19
3.4ay
2x32W
3.2av
2x16W
3.30
3.19
3.4ay
2x32W
3.7bi
2x32W
3.7bi
ELETRODUTO DE FERRO GALVANIZADO A FOGO DO TIPO PESADO (NBR-13057) INSTALADO
3.7bf
3.7bh
3.7be
3.30
3.23
3.7bh
3.7bi
3.23
3.7be
2x16W
CANALETA EM PVC COM SEPTO (DUAS VIAS), NA COR BRANCA, INSTALADA A 30cm DO PISO
3.7bf
2x16W
3.23
CANALETA FIXADA
PAVIMENTO
ARQUITETURA)
INCORPORADOS INTERNAMENTE AO PROJETOR, DISPOSITIVO DE FECHAMENTO
ESCALA: .......................................................... 1/50
EQUIPAMENTOS AUXILIARES PELA ABERTURA FRONTAL DA LENTE DE VIDRO,
PERCURSOS DE CABOS:
A
GRELHA.
B
C
NOTAS GERAIS:
D
E
"220V".
F
G
H
6 - TODOS OS ELETRODUTOS OU TRECHOS DE ELETRODUTOS APARENTES OU NO INTERIOR DE
GALVANIZADO DO TIPO PESADO, CONFORME NBR 13.057.
I
CIRCUITO
XX
XXXVA
J
XX
XXXVA
XX
XXXVA
K
F
ADESIVA
PAREDE DA
ELETROCALHA
BUCHA
TOMADA EM VA
TIPO "D"
CHUMBADOR CBA
N
ELETRODUTO
ELETROCALHA.
T
ARRUELA
L
ELETRODUTO DE
F N
T
BUCHA E ARRUELA
GALVANIZADO
M
ELETROCALHA LISA
COM TAMPA
FASE: PRETO - NEUTRO: AZUL CLARO - TERRA: VERDE - RETORNO: BRANCO - RETORNO PARALELO:
CINZA.
ALARME
PNE
ELETRODUTO DE
ELETRODUTO DE
N
F
ATIRANTADAS) NA LAJE.
R
O
SEM ESCALA
SEM ESCALA - SUPORTAR A CADA 1,50m
CONDULETE
P
SEM ESCALA
COM TAMPA
Q
R
ELETRODUTO NA ELETROCALHA
S
SEM ESCALA
14 - O MEMORIAL DESCRITIVO E QUANTITATIVO FAZEM PARTES INTEGRANTES DESTE PROJETO, E
100
T
FIXADOS SOBRE A PAREDE COM
CAIXA DE PASSAGEM EM PVC DE SOBREPOR
200x200x100mm PARA A PASSAGEM DOS CABOS
V
PAREDE A UMA ALTURA DE 30,0cm DO PISO
ACABADO
100
U
PROJETO)
TIPO "CBA"
LAJE
PASSAGEM DOS CABOS DE
DADOS / VOZ E ALARME
PASSAGEM DOS CABOS
ELETRICOS (CIRCUITOS DE
W
SUPORTE DE
EQUIPAMENTOS EM CAIXA
ALTA NA COR BRANCA COM
(DUTO DUPLO) FIXADO NA PAREDE PARA A
CABEAMENTO ESTRUTURADO
50
300
PT-XX-NN
PT-XX-NN
38
VER PLANTA
INSTALADO SOBRE O DUTO
EM PVC
XX
XXXVA
73
XX
XXXVA
VISTA LATERAL DA
CANALETA
2150
TIPO "CBA"
100
2200
DUTO EM PVC COM TAMPA NA COR BRANCA
PASSAGEM DOS CABOS
ELETRICOS (CIRCUITOS DE
AR-CONDICIONADO)
REV.02
14/08/2012
BRENO
REV.01
17/07/2012
BRENO
REV.00
04/05/2012
BRENO
OCORR.
DATA
RESP.
PROJETO EXECUTIVO
PARA:
ELETROCALHA 200mm: UTILIZAR
19
SOBRE O DUTO EM PVC
Y
250
SUPORTE DE EQUIPAMENTOS EM CAIXA
X
2"x1/4"
PARAFUSO M6 COM PORCA,
ARRUELA LISA E ARRUELA
PROJETO)
PERFILADO
PERFURADO
38x19mm PARA
VER PLANTA
PARAFUSO M6 COM
PORCA, ARRUELA
LISA E ARRUELA DE
ELETROCALHA 300mm: UTILIZAR
TJMG
DUTO EM PVC NAS
2 - ESQUEMA DE ATERRAMENTO ADOTADO: TN-S.
COMO BD-3.
SEM ESCALA
SEM ESCALA
4 - TEMPERATURAS CONSIDERARADAS EM PROJETO:
ESTADO DE MINAS GERAIS
SEM ESCALA
CENTRO
PROJETO
REFORMA
60.669-1;
ABNT NBR 14.136;
- DISJUNTORES ACIMA DE 125A (CAIXA MOLDADA): ABNT NBR IEC 60.947-2;
PROJETO EXECUTIVO
D
- DISPOSITIVOS DIFERENCIAL RESIDUAL (DR): ABNT NBR NM 61.008;
- DISPOSITIVOS PROTETORES DE SURTOS (DPS): NBR IEC 61.643-1;
- DUTOS CORRUGADOS DE POLIETILENO (PE) PARA INFRAESTRUTURAS DE ENERGIA E
14/08/2012
ABNT NBR 10.898;
Av. Augusto de Lima, 655, cj. 418
Centro - Belo Horizonte/MG
Telefax: (31) 3324-2702
http://www.viabile.com.br
[email protected]
SIMBOLOGIA, NOTAS GERAIS
DETALHES CONSTRUTIVOS
abrasip-mg
FORMATO INTERNACIONAL A0 (1189 x 841mm)
BRENO ASSIS
02/04
Download

Itauna ELE EX01 02-04