Guide: Installing and Adjusting the Flow Switch FLOW DETECTOR - FLOW SWITCH Wherever HIDRION SAL is installed and there is a possibility of the cell being switched on without water running through it, we recommend installing an optional accessory (Flow switch) which automatically stops production when water is not flowing through the cell. When the cell is installed in a by-pass to the main pump system, a flow switch must be used. 1 - Operation and Connection the HIDRION SAL Switchboard The flow switch detects the flow of water, activates the switch and automatically switches HIDRION SAL on. There are two shunted electrical contacts accessible on the outside of the HIDRION SAL switchboard which are for use with a flow switch (contacts 1 and 3), according to the figures and diagram below: 1 COM 3 NA Remove SHUNT 1 Electric wire: 2 2 x 0.75mm 3 ___________________________________________________________________________________________________________________ PRODUCED BY HIDROSWIM Lda. RUA MARTINS BARATA Nº 5E – 1400 – 247 LISBOA - TEL. +351 213 039 020 / FAX +351 213 039 022 (V20120507) WWW.HIDRION.PT 2 NOTE: the flow switch is an optional accessory, and can be supplied separately. 2 – Installation The flow switch is supplied with a series of paddles, which can be used with different diameters of pipe: T 50 x 1” The flow switch is supplied with a PVC accessory (T 50 x 1”) to be installed (glued) in the piping before the salt cell, following the flow direction shown on the lid of the flow switch. Flow switch Cut-off valve By-pass set-up ___________________________________________________________________________________________________________________ PRODUCED BY HIDROSWIM Lda. RUA MARTINS BARATA Nº 5E – 1400 – 247 LISBOA - TEL. +351 213 039 020 / FAX +351 213 039 022 (V20120507) WWW.HIDRION.PT 3 3 – Adjusting the flow switch The flow switch can be adjusted by turning the screw clockwise to activate the cell at higher flow rates, or anticlockwise to activate the cell at lower flow rates. 1 - Adjustment screw 2 - Fixing shim 3 - Microswitch protection NOTE: We recommend setting the screw to MINIMUM SETTING, which means minimum spring tension and operating flow rate. OPERATING FLOW RATE: MINIMUM SETTINGS Pipe Diameter 50mm 63mm Flow increase 43.33l/min 50.00l/min Flow decrease 31.67l/min 36.67l/min Once the flow switch has been adjusted, the screw should be secured using the fixing shim. The user is protected from accidental contact with the parts of the flow switch attached to electric current, thanks to insulation covering the microswitch. 4 - Technical properties Maximum operating pressure: Maximum flow temperature: Minimum flow temperature: Maximum ambient temperature: Connection to pipes: Adapted for pipes: Protection: 10 bar 120°C -30°C 55°C 1” from 1” to 8” IP 54 ___________________________________________________________________________________________________________________ PRODUCED BY HIDROSWIM Lda. RUA MARTINS BARATA Nº 5E – 1400 – 247 LISBOA - TEL. +351 213 039 020 / FAX +351 213 039 022 (V20120507) WWW.HIDRION.PT 4