Lovibond® Accessories
Tintometer® Group
Cells / Cuvettes
•
•
•
•
•
•
High Quality Optical Cells
Precision Technology
Heat Fused - Durable and Strong
Suitable for Heated Samples
Bevelled Edging - Easy Placement
Blemish Free
www.lovibond.com
General
Lovibond® optical cells are used in all types of spectro-photometers, fluorimeters, absorptiometers and
colorimeters throughout the world. The accuracy of the results obtained from these instruments must in
part depend on the accuracy of the cell used.
Lovibond® cells are manufactured by a specially developed fusing process which makes them resistant to
acids and chemical attack. Only highest grade materials are used and all Lovibond® cells are thoroughly
checked for quality and accuracy.
Applications for Lovibond® Cells
Beers, Malts & Caramels
Chemicals
Coatings
Edible Oils & Fats
Food & Beverages
Household Products
Medical and Clinical
Petroleum Oils & Waxes
Pharmaceuticals
Plastics
Sugar, Syrups & Honeys
Textiles
Environmental Water
Industrial Water
Potable & Waste
Water
Transmission Curves
100
90
80
70
Transmittance %
60
Optical Glass
50
ES Glass
ES Quartz
40
IR Quartz
30
20
10
0
0
1000
2000
3000
Wavelength nm
4000
5000
6000
Liquid Reference Standards
The advantage of liquid reference standards is that they can be used with the supplied cell
to check any liquid measuring instrument, not just Lovibond® instruments. This means the
operator can verify inter-instrument agreement between different instruments. At the same
time, it is possible to check the application and how the samples are being prepared and
presented to the instrument, in other words, make sure there are no finger prints on the cell
or, in the case of heated samples, no thermal currents in the sample liquid.
Confidence in Colour Measurement
For regular conformance checking, Certified Reference Solutions are supplied with full
traceability to internationally recognised standards, either ISO/IEC 17025:2000 (ASTM Color,
Saybolt and Gardner Colour) or the ISO 9001:2000 quality system (Pt-Co Units). This confirms
that they have been manufactured and inspected under the control of The Tintometer Ltd’s
ISO 9001:2000 quality system.
Materials
Code
Optical Glass1 or
Borosilicate2 Glass
(depending on the composition of the cell - for all requirements in the
visible range)
ES3 Quartz Glass with 80% transmission at 200nm
Quartz - for the I.R. range
OG
B
ES
IR
Cells made from Optical Glass conform to British Standard 3875.
Borosilicate glass has a very low coefficient of thermal expansion, making it resistant
to thermal shock and therefore less likely to crack when heated and cooled. It is
recommended for use with hot samples.
3
The transmission range for Extrasil ES quartz is from 170 - 2,500nm. In this range,
Extrasil ES quartz transmits at over 80%.
1
2
Note, the dimensions provided for the individual cells on the following pages represent the external dimensions.
Matching
If required, cells can be matched for transmission in sets of two and four at extra cost as follows:
CELLWAVE LENGTH
TOLERANCE %
OPTICAL GLASS
OG
365 nm
0.5
ES QUARTZ GLASS ES
200 nm
0.5
QUARTZ IR
IR
2730 nm
1.5
Pricing available on request.
Special Cells
Lovibond® Special Cell Department is available for making any cell to customers’ own requirements providing that such a cell is technically possible.
Quotations for special cells will be sent on receipt of drawings or sketches giving relevant details of material and exact measurements.
Packaging
All Lovibond® Spectrophotometer cells are supplied in attractive presentation cases. Other types of cells are suitably packed and shipped according to size
and quantity ordered.
Care and Cleaning of Cells
It is important to recognise that Lovibond® optical cells are delicate scientific apparatus and great care should be taken in cleaning them before and
after use. Contamination by dirt can lead to relatively large instrumental errors. The cell windows can be stained by leaving the cell filled with certain
samples. The following methods of cleaning are recommended.:
1) The cell should be brought to the boil slowly from cold and boiled for 15 minutes in a 2% solution of detergent in distilled water, rinsed thoroughly
in distilled water and finally in ethanol before allowing to dry. Any deposit on the faces should be removed by washing in 5% hydrochloric acid before
rinsing in water.
2) Staining can be removed by immersing the cell in freshly prepared chromic acid and leaving overnight. The cell should then be rinsed and dried per
above. Cells should not be allowed to dry out at any intermediate stage.
NEVER attempt to clean a cell by pushing cloth down inside it because the leverage may crack the face. When the cells are not in use, store in fitted
cases so as to protect the windows from accidental damage.
www.lovibond.com
W 100
Standard Spectrophotometer Cell without lid.
Path Length (mm)
OG
1
601010
2
601020
5
601030
10
601040
20
601050
40
601060
50
601070
100
601090
Material:
Optical Glass (OG) only.
W 110
Standard Spectrophotometer Cell with lid.
Material:
Special Optical Glass (SO) : Quartz (UV)
Path Length (mm)
UV (Pk 1)
UV (Pk 6)
OG (Pk 1)
1
601014
2
601024
5
601034
10
661130
661134
20
661140
661144
40
601064
50
661160
661164
601160
100
Path Length (mm)
OG
5
601410
10
601420
20
601430
40
601450
50
601460
601094
W 140
Spectrophotometer Cell with lid.
Material:
Optical Glass (OG) only
W 240
Cylindrical Spectrophotometer Cell with single stopper.
Material:
Optical Glass (OG) : Quartz (IR)
Path Length (mm)
OG
IR
10
602402
682402
20
602403
682403
50
602606
682406
100
602407
682407
OG (Pk 10)
W 250
Cylindrical Spectrophotometer Cell with two stoppers.
Material:
Optical Glass (OG) : Quartz (IR)
Path Length (mm)
OG
IR
10
602501
682501
20
602503
682503
50
602506
682406
100
602507
682407
W 260
Semi-micro cell of low capacity with lid (no lid with Optical Glass. Internal width 4mm.
Material:
Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR)
Path Length (mm)
OG
ES
IR
5
602601
632601
682601
10
602602
632602
682602
20
602603
632603
682603
30
602604
632604
682604
40
602605
632605
682605
50
602606
632606
682606
W 270
Semi-micro cell of low capacity with lid (no lid with Optical Glass). Internal width 4mm
Walls constructed of black glass to prevent light scatter.
Material:
Optical Glass (OG) : ES Quartz Glass (ES)
Path Length (mm)
OG
ES
5
602701
632701
10
602702
632702
20
602703
632703
30
602704
632704
40
602705
632705
50
602752
632706
100
602707
632707
W 300
Stoppered semi-micro cell. Internal width 4mm.
Material:
Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR)
Path Length (mm)
OG
ES
IR
5
603001
633001
683001
10
603002
633002
683002
20
603003
633003
683003
30
603004
633004
683004
40
603005
633005
683005
50
603006
633006
683006
W 310
Stoppered micro cell. Internal width 2mm.
Material:
Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR)
Path Length (mm)
OG
ES
IR
10
603102
633102
683102
20
603103
633103
683103
W 350
Micro-cell of low capacity with lid (no lid with Optical Glass). Internal width 2mm
Walls constructed of black glass to prevent light scatter.
Window Material:
Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR)
www.lovibond.com
Path Length (mm)
OG
ES
IR
10
603502
633502
683502
W 360
Micro-cell with lid (no lid with Optical Glass). Internal width 2mm
Window Material:
Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR)
Path Length (mm)
OG
ES
IR
5
603601
633601
683601
10
603602
633602
683602
20
603603
633603
683603
W 420
Flow through cell with two extension tubes with ground joints for inlet and outlet. Internal width 4mm.
Material:
Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR)
Path Length (mm)
OG
10
658020
W 480
Path Length (mm)
OG
ES
IR
5
604801
634801
684801
10
604802
634802
684802
20
604803
634803
684803
30
604804
634804
684804
40
604805
634805
684805
50
604806
634806
684806
100
604807
634807
684807
Fluorimeter cell with lid - four
sides and base polished.
Material:
Optical Glass (OG) :
ES Quartz Glass (ES) :
Quartz (IR)
Path Length (mm)
OG
ES
IR
5
604901
634901
684901
10
604902
634902
684902
20
604903
634903
684903
30
604904
634904
684904
40
604905
634905
684905
50
604906
634906
684906
100
604907
634907
684907
W 540
Absorptiometer cell without lid.
Path Length (mm)
OG
10
605400
W 490
Stoppered Fluorimeter cell
with lid - four sides and base
polished.
Material:
Optical Glass (OG) :
ES Quartz Glass (ES) :
Quartz (IR)
Material:
Optical Glass (OG)
W 550
Absorptiometer cell without lid.
Material:
Optical Glass (OG) only
Path Length (mm)
OG (Pk 1)
OG (Pk 10)
2.5
605510
605514
5
605520
605524
10
605530
605534
20
605540
605544
40
605550
605554
80
605560
605564
100
605570
605574
Path Length (mm)
OG
10
605800
Path Length (mm)
OG (Pk 1)
2.5
605610
5
605620
OG (Pk 10)
10
605630
605634
15
605640
605644
20
605645
40
605650
W 560
Absorptiometer cell without lid.
Material:
Optical Glass (OG) only
605654
W 580
Sedimentometer cell without lid.
Material:
Optical Glass (OG) only
Path Length (mm)
W 600
Cell for Lovibond® instrument.
Material:
Optical Glass (OG) only
These cells can also be made in heatresistant Borosilicate for waxes.
OG
B
Path Length (in)
OG
B
2.5
605940
655940
1/16
606040
656040
5
605950
655950
1/8
606050
656050
10
605960
655960
1/4
606060
656060
15
605970
655970
1/2
606070
656070
20
605980
655980
1
606080
656080
25
605990
655990
2
606090
656090
30
606000
656000
3
606100
656100
33
606010
656010
4
606110
656110
40
606020
656020
5
606120
656120
50
606200
656200
5 1/4
606130
656130
100
606030
656030
6
606150
656150
Path Length (mm)
OG
Path Length (mm)
OG
1
606750
15
606840
2.5
606780
20
606850
5
606790
25
606860
10
606810
26
606870
13
606820
33
606880
13.5
606830
40
606890
50
606930
W 680
Cell for Lovibond® 3-Field Comparator and other makes of Comparators and Colorimeters without lid.
Material:
Optical Glass (OG) only
Path Length (mm)
OG
2
606920
10
606900
20
606910
www.lovibond.com
W 690
Large face observation cell without lid.
Material:
Optical Glass (OG) only
The Tintometer Ltd
Lovibond House, Solar Way
Solstice Park
Amesbury, SP4 7SZ
UNITED KINGDOM
Tintometer GmbH
Lovibond® Water Testing
Schleefstraße 8-12
44287 Dortmund
GERMANY
Tintometer North America
6456 Parkland Drive
Sarasota
FL 34243
USA
Tel.: +44 (0)1980 664800
Fax: +44 (0)1980 625412
Tel.: +49 (0)231 94510-0
Fax: +49 (0)231 94510-20
Tel.: +1 941-758-8671
Fax: +1 941-727-9654
Toll Free: 855-Color12 (855-265-6712)
Tintometer - South East Asia
Unit B-3-12, BBT One Boulevard,
Lebuh Batu Nilam 2, Bandar Bukit Tinggi,
Klang, 41200, Selangor D.E.
MALAYSIA
Tintometer - China
Room 1001, China Life Tower,
16 Chaoyangmenwai Avenue,
Beijing, 100020
CHINA
Tel.: +603 3325 2286
Fax: +603 3325 2287
Tel.: +86 10 85251111 Ext. 330
Fax: +86 10 85251001
[email protected]
www.lovibond.com
Lovibond® and Tintometer® are Registered Trade Marks
of The Tintometer Limited. All translations and
transliterations of LOVIBOND® & TINTOMETER® are
asserted as Trade Marks of The Tintometer Limited.
Registered Office: Lovibond House, UK.
Registered in England No. 45024 Errors and Omissions Excepted Content Subject to alterations without notice.
937040_V1_05/12
Download

Cell Brochure - Lovibond Colour | Colour Measurement