Lovibond® Accessories Tintometer® Group Cells / Cuvettes • • • • • • High Quality Optical Cells Precision Technology Heat Fused - Durable and Strong Suitable for Heated Samples Bevelled Edging - Easy Placement Blemish Free www.lovibond.com General Lovibond® optical cells are used in all types of spectro-photometers, fluorimeters, absorptiometers and colorimeters throughout the world. The accuracy of the results obtained from these instruments must in part depend on the accuracy of the cell used. Lovibond® cells are manufactured by a specially developed fusing process which makes them resistant to acids and chemical attack. Only highest grade materials are used and all Lovibond® cells are thoroughly checked for quality and accuracy. Applications for Lovibond® Cells Beers, Malts & Caramels Chemicals Coatings Edible Oils & Fats Food & Beverages Household Products Medical and Clinical Petroleum Oils & Waxes Pharmaceuticals Plastics Sugar, Syrups & Honeys Textiles Environmental Water Industrial Water Potable & Waste Water Transmission Curves 100 90 80 70 Transmittance % 60 Optical Glass 50 ES Glass ES Quartz 40 IR Quartz 30 20 10 0 0 1000 2000 3000 Wavelength nm 4000 5000 6000 Liquid Reference Standards The advantage of liquid reference standards is that they can be used with the supplied cell to check any liquid measuring instrument, not just Lovibond® instruments. This means the operator can verify inter-instrument agreement between different instruments. At the same time, it is possible to check the application and how the samples are being prepared and presented to the instrument, in other words, make sure there are no finger prints on the cell or, in the case of heated samples, no thermal currents in the sample liquid. Confidence in Colour Measurement For regular conformance checking, Certified Reference Solutions are supplied with full traceability to internationally recognised standards, either ISO/IEC 17025:2000 (ASTM Color, Saybolt and Gardner Colour) or the ISO 9001:2000 quality system (Pt-Co Units). This confirms that they have been manufactured and inspected under the control of The Tintometer Ltd’s ISO 9001:2000 quality system. Materials Code Optical Glass1 or Borosilicate2 Glass (depending on the composition of the cell - for all requirements in the visible range) ES3 Quartz Glass with 80% transmission at 200nm Quartz - for the I.R. range OG B ES IR Cells made from Optical Glass conform to British Standard 3875. Borosilicate glass has a very low coefficient of thermal expansion, making it resistant to thermal shock and therefore less likely to crack when heated and cooled. It is recommended for use with hot samples. 3 The transmission range for Extrasil ES quartz is from 170 - 2,500nm. In this range, Extrasil ES quartz transmits at over 80%. 1 2 Note, the dimensions provided for the individual cells on the following pages represent the external dimensions. Matching If required, cells can be matched for transmission in sets of two and four at extra cost as follows: CELLWAVE LENGTH TOLERANCE % OPTICAL GLASS OG 365 nm 0.5 ES QUARTZ GLASS ES 200 nm 0.5 QUARTZ IR IR 2730 nm 1.5 Pricing available on request. Special Cells Lovibond® Special Cell Department is available for making any cell to customers’ own requirements providing that such a cell is technically possible. Quotations for special cells will be sent on receipt of drawings or sketches giving relevant details of material and exact measurements. Packaging All Lovibond® Spectrophotometer cells are supplied in attractive presentation cases. Other types of cells are suitably packed and shipped according to size and quantity ordered. Care and Cleaning of Cells It is important to recognise that Lovibond® optical cells are delicate scientific apparatus and great care should be taken in cleaning them before and after use. Contamination by dirt can lead to relatively large instrumental errors. The cell windows can be stained by leaving the cell filled with certain samples. The following methods of cleaning are recommended.: 1) The cell should be brought to the boil slowly from cold and boiled for 15 minutes in a 2% solution of detergent in distilled water, rinsed thoroughly in distilled water and finally in ethanol before allowing to dry. Any deposit on the faces should be removed by washing in 5% hydrochloric acid before rinsing in water. 2) Staining can be removed by immersing the cell in freshly prepared chromic acid and leaving overnight. The cell should then be rinsed and dried per above. Cells should not be allowed to dry out at any intermediate stage. NEVER attempt to clean a cell by pushing cloth down inside it because the leverage may crack the face. When the cells are not in use, store in fitted cases so as to protect the windows from accidental damage. www.lovibond.com W 100 Standard Spectrophotometer Cell without lid. Path Length (mm) OG 1 601010 2 601020 5 601030 10 601040 20 601050 40 601060 50 601070 100 601090 Material: Optical Glass (OG) only. W 110 Standard Spectrophotometer Cell with lid. Material: Special Optical Glass (SO) : Quartz (UV) Path Length (mm) UV (Pk 1) UV (Pk 6) OG (Pk 1) 1 601014 2 601024 5 601034 10 661130 661134 20 661140 661144 40 601064 50 661160 661164 601160 100 Path Length (mm) OG 5 601410 10 601420 20 601430 40 601450 50 601460 601094 W 140 Spectrophotometer Cell with lid. Material: Optical Glass (OG) only W 240 Cylindrical Spectrophotometer Cell with single stopper. Material: Optical Glass (OG) : Quartz (IR) Path Length (mm) OG IR 10 602402 682402 20 602403 682403 50 602606 682406 100 602407 682407 OG (Pk 10) W 250 Cylindrical Spectrophotometer Cell with two stoppers. Material: Optical Glass (OG) : Quartz (IR) Path Length (mm) OG IR 10 602501 682501 20 602503 682503 50 602506 682406 100 602507 682407 W 260 Semi-micro cell of low capacity with lid (no lid with Optical Glass. Internal width 4mm. Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Path Length (mm) OG ES IR 5 602601 632601 682601 10 602602 632602 682602 20 602603 632603 682603 30 602604 632604 682604 40 602605 632605 682605 50 602606 632606 682606 W 270 Semi-micro cell of low capacity with lid (no lid with Optical Glass). Internal width 4mm Walls constructed of black glass to prevent light scatter. Material: Optical Glass (OG) : ES Quartz Glass (ES) Path Length (mm) OG ES 5 602701 632701 10 602702 632702 20 602703 632703 30 602704 632704 40 602705 632705 50 602752 632706 100 602707 632707 W 300 Stoppered semi-micro cell. Internal width 4mm. Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Path Length (mm) OG ES IR 5 603001 633001 683001 10 603002 633002 683002 20 603003 633003 683003 30 603004 633004 683004 40 603005 633005 683005 50 603006 633006 683006 W 310 Stoppered micro cell. Internal width 2mm. Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Path Length (mm) OG ES IR 10 603102 633102 683102 20 603103 633103 683103 W 350 Micro-cell of low capacity with lid (no lid with Optical Glass). Internal width 2mm Walls constructed of black glass to prevent light scatter. Window Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) www.lovibond.com Path Length (mm) OG ES IR 10 603502 633502 683502 W 360 Micro-cell with lid (no lid with Optical Glass). Internal width 2mm Window Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Path Length (mm) OG ES IR 5 603601 633601 683601 10 603602 633602 683602 20 603603 633603 683603 W 420 Flow through cell with two extension tubes with ground joints for inlet and outlet. Internal width 4mm. Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Path Length (mm) OG 10 658020 W 480 Path Length (mm) OG ES IR 5 604801 634801 684801 10 604802 634802 684802 20 604803 634803 684803 30 604804 634804 684804 40 604805 634805 684805 50 604806 634806 684806 100 604807 634807 684807 Fluorimeter cell with lid - four sides and base polished. Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Path Length (mm) OG ES IR 5 604901 634901 684901 10 604902 634902 684902 20 604903 634903 684903 30 604904 634904 684904 40 604905 634905 684905 50 604906 634906 684906 100 604907 634907 684907 W 540 Absorptiometer cell without lid. Path Length (mm) OG 10 605400 W 490 Stoppered Fluorimeter cell with lid - four sides and base polished. Material: Optical Glass (OG) : ES Quartz Glass (ES) : Quartz (IR) Material: Optical Glass (OG) W 550 Absorptiometer cell without lid. Material: Optical Glass (OG) only Path Length (mm) OG (Pk 1) OG (Pk 10) 2.5 605510 605514 5 605520 605524 10 605530 605534 20 605540 605544 40 605550 605554 80 605560 605564 100 605570 605574 Path Length (mm) OG 10 605800 Path Length (mm) OG (Pk 1) 2.5 605610 5 605620 OG (Pk 10) 10 605630 605634 15 605640 605644 20 605645 40 605650 W 560 Absorptiometer cell without lid. Material: Optical Glass (OG) only 605654 W 580 Sedimentometer cell without lid. Material: Optical Glass (OG) only Path Length (mm) W 600 Cell for Lovibond® instrument. Material: Optical Glass (OG) only These cells can also be made in heatresistant Borosilicate for waxes. OG B Path Length (in) OG B 2.5 605940 655940 1/16 606040 656040 5 605950 655950 1/8 606050 656050 10 605960 655960 1/4 606060 656060 15 605970 655970 1/2 606070 656070 20 605980 655980 1 606080 656080 25 605990 655990 2 606090 656090 30 606000 656000 3 606100 656100 33 606010 656010 4 606110 656110 40 606020 656020 5 606120 656120 50 606200 656200 5 1/4 606130 656130 100 606030 656030 6 606150 656150 Path Length (mm) OG Path Length (mm) OG 1 606750 15 606840 2.5 606780 20 606850 5 606790 25 606860 10 606810 26 606870 13 606820 33 606880 13.5 606830 40 606890 50 606930 W 680 Cell for Lovibond® 3-Field Comparator and other makes of Comparators and Colorimeters without lid. Material: Optical Glass (OG) only Path Length (mm) OG 2 606920 10 606900 20 606910 www.lovibond.com W 690 Large face observation cell without lid. Material: Optical Glass (OG) only The Tintometer Ltd Lovibond House, Solar Way Solstice Park Amesbury, SP4 7SZ UNITED KINGDOM Tintometer GmbH Lovibond® Water Testing Schleefstraße 8-12 44287 Dortmund GERMANY Tintometer North America 6456 Parkland Drive Sarasota FL 34243 USA Tel.: +44 (0)1980 664800 Fax: +44 (0)1980 625412 Tel.: +49 (0)231 94510-0 Fax: +49 (0)231 94510-20 Tel.: +1 941-758-8671 Fax: +1 941-727-9654 Toll Free: 855-Color12 (855-265-6712) Tintometer - South East Asia Unit B-3-12, BBT One Boulevard, Lebuh Batu Nilam 2, Bandar Bukit Tinggi, Klang, 41200, Selangor D.E. MALAYSIA Tintometer - China Room 1001, China Life Tower, 16 Chaoyangmenwai Avenue, Beijing, 100020 CHINA Tel.: +603 3325 2286 Fax: +603 3325 2287 Tel.: +86 10 85251111 Ext. 330 Fax: +86 10 85251001 [email protected] www.lovibond.com Lovibond® and Tintometer® are Registered Trade Marks of The Tintometer Limited. All translations and transliterations of LOVIBOND® & TINTOMETER® are asserted as Trade Marks of The Tintometer Limited. Registered Office: Lovibond House, UK. Registered in England No. 45024 Errors and Omissions Excepted Content Subject to alterations without notice. 937040_V1_05/12