Multisplit Alta Capacidade
MÓDULO DE VENTILAÇÃO 40MZB
MÓDULO TROCADOR DE CALOR 40MZB
UNIDADE CONDENSADORA 38AB
UNIDADE CONDENSADORA 38MZ
Catálogo Técnico
Índice
1 INTRODUÇÃO ...................................................................................... 3
2 CARACTERÍSTICAS GERAIS .............................................................. 4
2.1
UNIDADE CONDENSADORA 38MZ .............................................. 4
2.2 UNIDADE CONDENSADORA 38AB .............................................. 4
2.3 MÓDULO DE VENTILAÇÃO 40MZB ............................................. 6
2.4 MÓDULO TROCADOR DE CALOR 40MZB ................................... 7
2.5 MÓDULO CAIXA DE MISTURA (OPCIONAL) ................................. 8
3
4
5
6
7
8
CARACTERÍSTICAS TÉCNICAS GERAIS ........................................... 9
DADOS ELÉTRICOS .......................................................................... 12
DADOS DIMENSIONAIS .................................................................... 15
PROCEDIMENTOS DE SELEÇÃO ..................................................... 19
TABELAS DE SELECIONAMENTO .................................................... 20
CURVAS DE VAZÃO .......................................................................... 26
8.1 MÓDULO DE VENTILAÇÃO 240 ................................................. 26
8.2 MÓDULO DE VENTILAÇÃO 300 ................................................. 26
8.3 MÓDULO DE VENTILAÇÃO 390 ................................................. 27
8.4 MÓDULO DE VENTILAÇÃO 480 ................................................. 27
8.5 MÓDULO DE VENTILAÇÃO 540 ................................................. 28
8.6 MÓDULO DE VENTILAÇÃO 630 ................................................. 28
9 DADOS PARA INSTALAÇÃO ............................................................. 29
10 TABELA DE UTILIZAÇÃO DAS CONDENSADORAS ......................... 29
11 TABELA DE DISPONIBILIDADE DE ITENS....................................... 30
1 - INTRODUÇÃO
A Carrier, sempre buscando ampliar as opções dos nossos
clientes e oferecendo o que há de melhor no mercado, estende a
sua consagrada linha de Multisplit para as capacidades de 240, 300,
390, 480, 540 e 630000 Btu/h.
2. CARACTERÍSTICAS GERAIS
RECOLHIMENTO DE CONDENSADO
GABINETES
A bandeja de recolhimento do condensado do evaporador
40MZ é em chapa de aço. Desenhada para proporcionar
drenagem 100% positiva, evitando assim corrosão.
40 MZB
As evaporadoras são construídas em chapas de aço
galvanizado e com revestimento de poliestireno expandido
interno. As evaporadoras 240/300/390/480/540/630 são
formadas pelos módulos trocador de calor e ventilação
fornecidos separadamente. Os painéis de fechamento são
facilmente removíveis para acesso aos componentes
internos. Acompanham a máquina chaves de abertura para
os painéis, facilitando a manutenção do equipamento.
2.1. UNIDADE CONDENSADORA 38MZ
Condensação a ar, compressor(es) SCROLL e quadro
elétrico incorporado.
REFRIGERAÇÃO E AQUECIMENTO
Os equipamentos podem refrigerar ou aquecer os
ambientes, desde que instalados com resistências de
aquecimento, fornecidas opcionalmente por nossos
instaladores credenciados. O fornecimento e a instalação
de acessórios deverão ser feitos pelo instalador
credenciado de sua escolha, garantindo assim o perfeito
funcionamento das unidades.
38MZ / 38AB
Construídos sobre estrutura de chapas de aço galvanizado
e fosfatizadas, os gabinetes das unidades condensadoras
38MZ e 38AB são revestidos por processo de pintura a
pó poliester em tons de cinza, com posterior secagem em
estufa. Os painéis de fechamento são facilmente
removíveis, permitindo total acesso aos componentes
internos.
NOMENCLATURA 38MZ
38
MZ
A
150
22
6
S
UNIDADE
CONDENSADORA
PADRÃO DE ESPECIFICAÇÕES
S - STANDARD
VENTILADOR CENTRÍFUGO
FREQÜÊNCIA NOMINAL
6 - 60Hz
IDENTIFICAÇÃO NA
ALTERAÇÃO DO PROJETO
MODELO
150
240
22 - 220V
TENSÃO NOMINAL
38 - 380V 44-440V
2.2. UNIDADE CONDENSADORA 38AB
NOMENCLATURA 38AB
38
AB
A
240
22
6
UNIDADE
CONDENSADORA
S
PADRÃO DE ESPECIFICAÇÕES
S - STANDARD
VENTILADOR AXIAL
FREQÜÊNCIA NOMINAL
6 - 60Hz
IDENTIFICAÇÃO NA
ALTERAÇÃO DO PROJETO
22 - 220V
MODELO
150 / 240 / 300 / 390 / 480
4
TENSÃO NOMINAL
38 - 380V 44-440V
POSIÇÕES DE MONTAGEM DA UNIDADE CONDENSADORA 38MZ
! IMPORTANTE
As unidades 38AB e 38MZ possuem resistências de
cárter nos compressores. Certifique-se de que todos os
compressores estejam aquecidos antes de partir.
OS AQUECEDORES DE CÁRTER DEVERÃO SER
ENERGIZADOS 24 HORAS ANTES DA PARTIDA.
OS AQUECEDORES DEVERÃO SER ENERGIZADOS
SEMPRE QUE A UNIDADE NÃO ESTIVER EM
OPERAÇÃO.
Entretanto, durante uma parada prolongada para
manutenção, os aquecedores poderão ser desenergizados.
Quando for restabelecida a operação normal, os
aquecedores de cárter deverão permanecer energizados
previamente durante 24 horas antes da partida da unidade.
A
B
C
A - Montagem de fábrica. / B e C - Conversão em campo.
QUADRO ELÉTRICO
OBS.: A Carrier não se responsabiliza por problemas
decorrentes da instalação das unidades em posição de
montagem que não sejam as acima indicadas.
Montado em fábrica nas unidades condensadoras, e com
uma tensão de comando de 24V-1ph-60Hz, o quadro
elétrico foi projetado para a mais absoluta segurança,
possuindo fusíveis de controle, contactores, relés de
sobrecarga e CLO. As conexões elétricas podem ser feitas
por ambos os lados nas unidades 38MZ e no lado direito
das unidades 38AB.
COMPRESSOR SCROLL
As unidades 38MZ / 38AB são equipadas com compressor
Scroll que proporcionam maior eficiência energética, menor
nível de ruído e, especialmente, aumento de confiabilidade
do principal componente do sistema de refrigeração.
PADRÃO DE ESPECIFICAÇÕES STANDARD (S)
- Pressostatos de alta e baixa, individuais, do tipo
miniaturizado e rearme automático;
- Filtro secador;
- Filtro de sucção;
- Válvulas de serviço 1/4" para tomada de pressão, vácuo e
carga de refrigerante nas linhas sucção descarga e líquido;
DISPOSITIVOS DE PROTEÇÃO DO COMPRESSOR SCROLL
• LINE BREAK E TERMOSTATO INTERNO- Dispositivo
montado internamente no estator do motor do compressor
scroll com a finalidade de proteger contra sobrecarga e
superaquecimento.
COMANDOS
• CLO (compressor lock-out) - Componente instalado no
quadro elétrico das condensadoras com a finalidade de evitar
a ciclagem automática do compressor.
Após a atuação dos pressostatos de alta ou baixa, do Line
Break ou do termostato interno, o rearme só é possível
desligando e religando a unidade no termostato ou chave
ON-OFF. Esta característica garante que os elementos de
proteção funcionem como sendo de rearme manual através
do painel elétrico.
Visando oferecer ao usuário um maior número de opções,
a Carrier disponibilizou em forma de Kits os comandos
Eletromecânicos, o controlador microprocessado Temp
System com ou sem relógio e o comando Digital Carrier
Programável e Não Programável listados abaixo:
- CKTMFR1A
- CKTMFR2A
- CKTMFR3A
- CKDCST1A
Kit comando Eletromecânico para 1 estágio
Kit comando Eletromecânico para 2 estágios
Kit comando Eletromecânico para 3 estágios
Kit comando Digital Carrier Não Programável
para 1 estágio.
- CKDCST2A - Kit comando Digital Carrier Não Programável
para 2 estágios.
- CKDCPG1A - Kit comando Digital Carrier Programável
para 1 estágio.
- CKDCPG2A - Kit comando Digital Carrier Programável
para 2 estágios.
• RESISTÊNCIA DE AQUECIMENTO DO CÁRTER
Todas as unidades condensadoras 38AB 150 até 38AB 480
e as unidades condensadoras 38MZ 150 e 38MZ 240 saem
da fábrica equipadas com resistência de cárter.
O uso da resistência de cárter é para previnir o acúmulo de
líquido refrigerante no óleo durante as paradas do
equipamento. Certifique-se que os aquecedores estão
firmemente presos para evitar que se desloquem. O
aquecedor tem sua fiação interligada ao painel nos contatos
normalmente fechados do contator de força, para que seja
energizado quando houver parada do compressor.
-
Estes Kits são amplamente descritos em literatura específica.
! AVISO
Os aquecedores do cárter estão ligados no circuíto de
controle. Por, isso estarão sempre energizados mesmo
que a máquina esteja DESLIGADA.
5
VENTILADORES
As características do DIGITAL CARRIER não
programável são:
- display de cristal líquido;
- controla os seguintes modos de operação: refrigeração,
aquecimento, desumidificação, ventilação, ou totalmente
automático;
- timer 24 horas com sensor integrado de temperatura.
As unidades condensadoras 38MZ possuem ventiladores
do tipo centrífugo, de dupla aspiração, com pás voltadas
para a frente (sirocco) e voluta em chapa de aço
galvanizado, dinâmica e estaticamente balanceados,
unidos através de eixo com mancais auto lubrificantes,
auto compensadores e blindados, os mesmos são
acoplados a motor trifásico através de transmissão por
correia e polia.
As unidades 38AB possuem ventiladores axiais, dinâmica
e estaticamente balanceados, acoplados diretamente ao
motor trifásico.
As características do DIGITAL CARRIER programável são:
- programação semanal com 4 períodos individuais por
dia para cada zona condicionada;
- range individual de 13°C a 32°C de temperatura para cada
zona;
- modo de operação individual para cada zona;
- modo de distribuição de ar individual para cada zona;
- programação de feriados;
- relógio;
- indicador das condições de filtro;
- indicador de falhas;
- display de cristal líquido.
SERPENTINA CONDENSADORA
Serpentinas de 2, 3 ou 4 filas (conforme modelo), de tubos
de cobre grooved, com diâmetro 3/8" expandidos contra
aletas do tipo Gold Fin (resistentes à corrosão), testados
quanto a resistência mecânica e vazamentos a 420 psig
e dotados de circuito de sub-resfriamento.
Nos Kits são enviados o painel de controle e também a
placa de relés, necessários para comandar compressor/
ventilador da unidade. Eles devem ser montados em
campo observando que a placa de relés eletrônicos (Relay
Pack) seja montada externamente à unidade, evitandose interferências eletromagnéticas, e que o painel deve
ser instalado junto ao ambiente a ser condicionado.
As conexões de refrigerante são para solda e estão
localizadas à esquerda da serpentina na unidade 38MZ
e à direita na unidade 38AB, podendo sair para os dois
lados em ambas as unidadades.
2.3. MÓDULO DE VENTILAÇÃO 40MZB
40
MZ
B
300
23
6
VS
H1
H1 - montagem horiz./descarga horiz.
H2 - montagem horiz./descarga superior/inferior
V1 - montagem vert./ descarga vertical
V2 - montagem vert./descarga frontal/traseira
MÓDULO DE VENTILAÇÃO
VS / VA / VH
FAIXA DE PRESSÕES - VER ITEM 3
MULTISPLIT ALTA CAPACIDADE
IDENTIFICAÇÃO NA
ALTERAÇÃO DO PROJETO
FREQUÊNCIA NOMINAL
6 - 60Hz
CAPACIDADE NOMINAL
240/300/390/480/540/630
23 - 220/380V
TENSÃO NOMINAL
44-440V
MOTOR E VENTILADOR
Os módulos de ventilação 40MZB utilizam ventiladores centrífugos de dupla aspiração com pás voltadas para a frente
(Sirocco). Possuem rotor em aço galvanizado, dinâmica e estaticamente balanceados, acionados por motor elétrico e
transmissão por correia e polia ajustável para diferentes combinações de vazão / pressão disponível (ver curvas de operação).
O módulo de ventilação 40MZB é fornecido avulso, devendo ser montado em conjunto com um módulo trocador de calor
40MZB de capacidade nominal igual de modo a formar uma unidade evaporadora para a aplicação desejada.
6
2.4. MÓDULO TROCADOR DE CALOR 40MZB
Trocador de calor de expansão direta tipo aletas e tubos com válvula de expansão termostática.
40
MZ
B
300
T
V
MÓDULO TROCADOR DE CALOR
V - montagem vertical
H - montagem horizontal
MULTISPLIT ALTA CAPACIDADE
TROCADOR DE CALOR
IDENTIFICAÇÃO NA
ALTERAÇÃO DO PROJETO
CAPACIDADE NOMINAL
240/300/390/480/540/630
FILTROS DE AR
O módulo trocador de calor 40MZB é fornecido com filtros
padrão G2, de 1 polegada de espessura. Os filtros são
de fácil remoção e limpeza.
POSIÇÕES DE MONTAGEM DO MÓDULO TROCADOR DE CALOR EM CONJUNTO COM O MÓDULO DE VENTILAÇÃO (EVAPORADOR 40MZB)
MONTAGEM HORIZONTAL
MONTAGEM VERTICAL
OBS: A montagem deve ser especificada no momento da compra.
7
2.5. MÓDULO CAIXA DE MISTURA (OPCIONAL)
DIMENSIONAL DOS FILTROS INCORPORADOS A CAIXA
DE MISTURA
A caixa de mistura para as unidades 40MZB é montada
sempre antes do módulo trocador de calor.
O Módulo Caixa de Mistura é fabricado com parede dupla
em chapa de aço galvanizado e isolamento interno de
poliestireno expandido com espessura de 1/2”. Possui
dampers fabricados em chapa de aço galvanizado, com
lâminas opostas e eixo para acionamento manual ou
automático.
Modelo
Quando montada, esta caixa de mistura incorpora uma
variedade de opções de filtros.
– G0 tela metálica 1”
– G2 fibra de vidro 1”
– G3 fibra de vidro 1”
– G0 tela metálica 1” + G2 fibra de vidro de 1”
– G0 tela metálica 1” + G3 fibra de vidro de 1”
– G2 fibra de vidro 2”
– G3 fibra de vidro 2”
Os filtros G2 e G3 fibra de vidro ainda possuem as
seguintes opções: ‘descartável’ ou ‘com moldura metálica’.
8
Dimensões dos Filtros (mm) Quant.
ITC18 - 40MZB 240
ITC20 - 40MZB 300
372 x 416
469 x 478
10
8
ITC25 - 40MZB 390
ITC30 - 40MZB 480
469 x 466
499 x 434
10
12
ITC35 - 40MZB 540
ITC40 - 40MZB 630
499 x 493
555 x 436
12
14
3. CARACTERÍSTICAS TÉCNICAS GERAIS
Unidade Evaporadora
40 MZB
Características
240
300
390
480
540
630
Capacidade (kcal/h) [1] com 38MZ
56810
70062
92480
110587
126707
148774
Capacidade (kcal/h) [1] com 38AB
57730
73370
94665
111400
130677
151500
Alimentação Principal (V / F / Hz)
220 , 380 , 440 / 3 / 60
Tensão de Comando (V / F / Hz)
24 / 1 / 60
N. circuitos frigoríficos
1
2
3
N. estágios de capacidade
1
2
3
Refrigerante - Tipo
R-22
Área face (m2)
1,4
1,65
2,05
2,34
2,74
3,13
N. filas
4
S
e
Diâmetro tubos
1/2”
r
Aletas
polegada
14
p
e
Tipo
Aletas Alumínio Corrugado e Tubos Cobre
n
N. circuitos
1
2
3
t
Linha Líquido
i
1 x 5/8” - solda
2 x 5/8” - solda
3 x 5/8” - solda
n
Quant./Diâmetro/Tipo
a
Linha Sucção
1 x 1 3/8” - solda
2 x 1 3/8” - solda
3 x 1 3/8” - solda
Quant./Diâmetro/Tipo
Tipo
Centrífugo Duplo
Centrífugo Triplo
V
e
Vazão ( m3/h )
10880 - 16320 13600 - 20400 17680 - 26520 21760 - 32640 24480 - 36720 28560 - 42840
n
VS
720 - 950
770 - 950
620 - 780
720 -900
800
800
t
Rotação (rpm)
i
VA
ND
ND
ND
920
860
860
l
VH
970 - 1220
1010 - 1200
790 - 990
950
925
925
a
VS
9 - 25
7 - 24
10 - 24
19 - 37
18
19
d
o
P.E.D. (mmCA)
VA
ND
ND
ND
39
26
26
r
VH
26 - 37
29 - 47
25 - 45
43
35
34
Quantidade - N. Pólos
1-4
M
o
VS
6 - 112M
7.5 - 112M
7.5 - 112M
12.5 - 132M
15 - 132M
20 - 160M
t
Potência (CV) - carcaça VA
ND
ND
ND
15 - 132M
20 - 160M
20 - 160M
o
r
VH
10 - 132S
10 - 132S
12.5 - 132M
15 - 132M
20 - 160M
20 - 160M
Correia V - Tipo/Quant.
B44 / 1
B57 / 1
B60 / 2
B55 / 2
B56 / 2
B65 / 2
Polia Motor (mm)
106 ~ 140
106 ~ 140
121.9 ~ 152.4 121.9 ~ 152.4
152,4
152,4
VS
A
c
Polia Ventilador ( mm)
253,8
253,8
345
296,4
334
334
i
o
Correia V - Tipo/Quant
ND
ND
ND
B56 / 3
B58 / 2
B68 / 2
n
a
VA
Polia Motor (mm)
ND
ND
ND
156,6
169
169
m
e
Polia Ventilador ( mm)
ND
ND
ND
296,8
345,4
345,4
n
t
Correia V - Tipo/Quant.
B42 / 2
B55 / 2
B58 / 2
B57 / 3
B56 / 2
B365 / 3
o
VH 121.9 ~ 152.5 121.9 ~ 152.5 121.9 ~ 152.5
Polia Motor (mm)
161,5
169
165
Polia Ventilador ( mm)
220
220
271
296,8
320
296,8
18 / 10 / 9
23 / 12.5 / 11.5 23 / 12.5 / 11.5 32 / 20 / 18.4 43.7 / 25 / 21.8
S
Regulagem Relé Sobrecarga VS
e
VA
ND
ND
ND
57 / 32 / 28
g
43.7 / 25 / 21.8
57 / 32 / 28
220 / 380 / 440 Volts
VH
31 / 17 / 16
31 / 17 / 16
32 / 20 / 18.4
Peso Evaporadora (T + V)
384
548
656
778
961
1134
[1] Condições ARI 210 TBS=26,7°C e TBU=19,4°C para o ar entrando na unidade evaporadora e 35°C para o ar entrando na unidade condensadora.
ND: Não disponível
D: Disponível
9
UNIDADE CONDENSADORA
CARACTERÍSTICAS
Alimentação Principal (V - F - Hz)
Tensão de Comando (V - F - Hz)
Nº de circuitos frigoríficos
Nº de estágios de capacidade
Refrigerante - Tipo
C
Tipo
O
M
Quantidade
P
R
U E Rotação (rpm)
N S Carga óleo (l)
S
I
O
D R Óleo recomendado
A
Área de face (m2)
S
D E
Nº
de filas
E R
P
Diâmetro
tubos
E
C N
Aletas
polegadas
O T
I
N N Tipo
D A Nº de circuitos
E
Linha líquido
N C
O
S N Diâmetro/Conexão
A E
X
D A Linha Sucção
O O Diâmetro/Conexão
R V
Tipo
A EN
T
Rotação (rpm)
I
L
3
Vazão (m3/h)
A
D
8
O
M R P.E.D. (mmca)
Z M Quantidade - nº pólos
O
T
O
Potência (CV) - carcaça
R
ALTA
D
I
S
P.
D
E
S
E
G.
BAIXA
Desarme (psig)
Rearme (psig)
Desarme (psig)
Rearme (psig)
Fusível de Comando (A)
Compressor Lock-out (CLO)
Line Break Interno
Termostato Interno
Relé de Sobrecarga (A) - Compr. 220/380/440
Relé de Sobrecarga (A) - Vent. 220/380/440
Peso
38 MZ
150
240
220, 380, 440V / 3 / 60
24V / 1 / 60
1
1
R-22
Scroll
1
3480
2.69
5.49
Mineral - 160P
1.37
1.77
3
4
3/8"
17
Aletas de alumínio corrugado com Pre-coated (Gold Fin) e Tubos de cobre ranhurados internamente
1
5/8" -solda
1 3/8 "- solda
Centrífugo Duplo
815
10200
720
15300
8
1-4
2 - 90S
3 - 90L
426
320
27
67
4
Garante o compressor contra ciclagem automática
Garante o compressor contra sobrecarga e superaquecimento
Garante o compressor contra sobrecarga e superaquecimento
70 / 40 / 37,5
8 / 4,4 / 3,2
9,8 / 5,7 / 4
350
412
10
UNIDADE CONDENSADORA
CARACTERÍSTICAS
Alimentação Principal (V - F - Hz)
Tensão de Comando (V - F - Hz)
Nº de circuitos frigoríficos
Nº de estágios de capacidade
Refrigerante - Tipo
C
Tipo
O
M
Quantidade
P
U R
Rotação (RPM)
E
N S
Carga de óleo por compressor (l)
S
I
O
D R
Óleo recomendado
A
Área de face (m 2)
S
D
E
Nº de filas
E R
P
Diâmetro dos tubos
E
C N
Aletas por polegadas
O T
I
N
Tipo
N
D A
Nº de circuitos
E
N C
Linha de líquido
S O
N
QTD - Diâmetro - Tipo
A E
Linha de sucção
D X
Ã
O O
QTD - Diâmetro - Tipo
R
Tipo - Quantidade
A
V
E
Rotação (RPM)
N
T.
3
Vazão (m3/h)
8
M
A O
Quantidade - nº de pólos
B TO
Potência (CV) - carcaça
R
Desarme (psig)
ALTA
Rearme (psig)
D
Desarme (psig)
BAIXA
I
Rearme (psig)
S
P.
Fusível de Comando (A)
Compressor Lock-out (CLO)
S
Line Break Interno Compr. Circ. 150
E
G
Termostato Interno Compr. Circ. 240
U
R
Relé de Sobrecarga
Compr. Circ. 150
A
(220/380/440V)
Compr. Circ. 240
N
Ç
Relé de Sobrecarga (220/380/440V) Vent.
A
Peso (Kg)
150
240
CONDENSADORA 38AB
300
220, 380 OU 440 / 3 / 60
24 / 1 / 60
1
1
390
480
2
2
R-22
Scroll
1
2
2,69
3480
2 X 2,69
Mineral - 160P
2.064
3
3/8"
5,49
2
2,69 / 5,49
2 X 5,49
4
17
15
Aletas de alumínio corrugados com Pre-coated (Gold Fin) e Tubos de cobre ranhurados internamente
1
2
1 - 5/8" -BOLSA
2 - 5/8" -BOLSA
1 - 1 1/8"- BOLSA
2 - 1 1/8"- BOLSA
Axial - 2
1140
38300
1130
43000
2-6
1 - 90S
D
ND
8.6 / 5.0 / 2.8
335
426
320
27
67
4
Garante o compressor contra ciclagem automática
D
D
D
ND
D
70 / 40 / 37.5
70 / 40 / 37.5
8.6 / 5.0 / 2.8
8.6 / 5.0 / 2.8
8.6 / 5.0 / 2.8
350
390
460
[1] Condições ARI 210 TBS=26,7ºC e TBU=19,4ºC para o ar entrando na unidade evaporadora e 35ºC para o ar entrando na unidade condensadora.
11
1,5 - 90S
ND
D
70 / 40 / 37.5
10.5 / 6.2 / 4.0
490
440V
220V 380V
440
440
12
NOTA:
1
1
1
1
1
1
2
2
2
2
2
2
1
1
1
1
2
2
2
2
Qtde.
Condensadora 38MZA150
32
32
32
32
32
32
32
32
32
32
16,2
16,2
16,2
16,2
16,2
16,2
16,2
16,2
16,2
16,2
18,5
18,5
18,5
18,5
18,5
18,5
18,5
18,5
18,5
18,5
50
50
50
50
50
50
50
50
50
50
25
25
25
25
25
25
25
25
25
25
28,9
28,9
28,9
28,9
28,9
28,9
28,9
28,9
28,9
28,9
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
12200
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Pot. Nom. Pot . Max.
220V
380V
220V
380V
CV
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
Compressor
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
4
4
4
4
4
4
4
4
4
4
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
2051
FLA [A] FLA [A]
220V
380V Pot. [W]
FLA [A] 440V
Motor
2
2
2
2
2
2
1
1
1
1
1
1
2
2
2
2
2
2
1
1
1
1
1
1
1
1
Condensadora 38MZA240
47,6
47,6
47,6
47,6
47,6
47,6
47,6
47,6
47,6
47,6
47,6
47,6
47,6
23,8
23,8
23,8
23,8
23,8
23,8
23,8
23,8
23,8
23,8
23,8
23,8
23,8
27,4
27,4
27,4
27,4
27,4
27,4
27,4
27,4
27,4
27,4
27,4
27,4
27,4
75
75
75
75
75
75
75
75
75
75
75
75
75
37,5
37,5
37,5
37,5
37,5
37,5
37,5
37,5
37,5
37,5
37,5
37,5
37,5
43,2
43,2
43,2
43,2
43,2
43,2
43,2
43,2
43,2
43,2
43,2
43,2
43,2
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
18230
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Pot. Nom. Pot . Max.
220V
380V
220V
380V
CV
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
Compressor
. Os motores dos ventiladores são trifásicos;
. A variação da voltagem deve ser no máximo ±10%;
. A bitola do alimentador será dimensionada da seguinte forma:
- Multiplicar por 1,25 a corrente máxima (Cor. Máx.) do maior compressor do conjunto;
- Somar a corrente máxima dos demais compressores e motores dos ventiladores do evaporador e condensadores do conjunto;
- Os cabos deverão ser classe 105OC ou superior;
. Dados nominais obtidos na avaliação ARI 210.
40MZB630446VH
40MZB630236VH 220 380
440
40MZB630236VA 220 380
440
40MZB630446VA
40MZB630236VS 220 380
440
40MZB630446VS
40MZB540446VH
40MZB540236VH 220 380
440
40MZB540446VA
40MZB540236VA 220 380
440
40MZB540236VS 220 380
440
40MZB540446VS
40MZB480446VH
40MZB480236VH 220 380
440
40MZB480236VA 220 380
440
40MZB480446VA
40MZB480446VS
40MZB480236VS 220 380
440
40MZB390446VH
40MZB390236VH 220 380
440
40MZB390236VS 220 380
440
40MZB390446VS
40MZB300446VH
40MZB300236VH 220 380
440
40MZB300236VS 220 380
440
40MZB300446VS
40MZB240446VH
40MZB240236VH 220 380
40MZB240446VS
40MZB240236VS 220 380
Modelo
Tensão
Qtde.
8,6
8,6
8,6
8,6
8,6
8,6
8,6
8,6
8,6
8,6
8,6
8,6
8,6
4,3
4,3
4,3
4,3
4,3
4,3
4,3
4,3
4,3
4,3
4,3
4,3
4,3
5
5
5
5
5
5
5
5
5
5
5
5
5
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2276
2776
2776
2776
2776
2776
2776
2776
2776
FLA [A] FLA [A]
220V
380V Pot. [W]
FLA [A] 440V
Motor
20
20
20
20
20
20
20
20
20
20
15
15
15
15
15
15
12,5
12,5
12,5
12,5
7,5
7,5
10
10
7,5
7,5
10
10
6
6
CV
50
50
50
50
50
38
38
38
32
32
19,9
26,3
19,9
26,3
16
25
25
25
25
25
19
19
19
16
16
9,95
13,1
9,95
13,1
8
28,9
28,9
28,9
28,9
28,9
22
22
22
18,5
18,5
11,5
15,2
11,5
15,2
9,2
FLA [A] 440V
17041
17041
17041
17041
17041
17041
17041
17041
17041
17041
12453
12453
12453
12453
12453
12453
10487
10487
10487
10487
6249
6249
8642
8642
6249
6249
8642
8642
5246
5246
41,6
47,6
56,5
66,4
86,8
63,4
92,6
99,6
136
117,8
235,4
102,6
205,2 118,4
102,6
205,2 118,4
99,6
199,2 114,9
86,3
172,5
80,25
160,4
70,1
140,1
81
77,3
66,95
133,7
54,9
109,9
49,8
57,4
440V
99,6
123,8
123,8
137,1
137,1
100,9
137,1
201,3 116,2 274,1 158,2
100,9
201,3 116,2 274,1 158,2
100,9
201,3 116,2 274,1 158,2
92,5
106,3 247,4 142,9
92,5
106,3 247,4 142,9
86,5
99,4
75,2
150,4
184
86,8
75,2
150,4
184
83,3
72,2
144,4
172
73,4
63,8
127,1
57,75
115
60,2
52,5
104,1
49,35
97,7
41,2
82,5
36,1
72,2
440V
I Nom. Total
[A]
66924
66924
66924
66924
66924
66924
61259
61259
61259
61259
56671
56671
49485
49485
49485
49485
47519
47519
42354
42354
38116
38116
34344
34344
31951
31951
27658
27658
24262
24262
72304
72304
72304
72304
72304
72304
66049
66049
66049
66049
61461
61461
53465
53465
53465
53465
51499
51499
45744
45744
41506
41506
37144
37144
34751
34751
29648
29648
26252
26252
315
315
315
315
315
315
250
250
250
200
200
160
160
160
125
160
160
160
160
160
160
125
125
125
100
100
80
80
80
63
80
80
200
200
200
200
200
200
160
160
160
125
125
100
100
440V
I Máx. Total
Fusível Total
[A]
Potência Potência Recomendado
Nominal Máxima
FLA [A] FLA [A]
220V 380V 220V 380V
Total [W] Total [W] 220V 380V
220V
380V Pot. [W]
Modulo Ventilação
4 - DADOS
ELÉTRICOS
13
440
440
440
440
380
380
380
380
220
220
220
440
440
440
440V
1
1
1
1
380
380
380
380V
Tensão
440
440
440
440
440V
220V
220
220
220
220
220V
380
380
380
380
Condensadora 38ABA240
1
1
1
1
32
32
16,2
16,2
50
50
25
25
[W]
28,9
28,9
I Max. [A] 440V
Compressor 1
18,5
18,5
I Nom. [A] 440V
[W]
10800
10800
10800
10800
[W]
2
2
2
2
1
1
1
1
3,77
1,89
1,89
[W]
2,18
2,18
FLA [A] 440V
3,77
Condensadora 38ABA300
12200
12200
12200
12200
[W]
[W]
962
962
962
962
1
1
1
1
23,8
23,8
27,4
27,4
Motor (cada)
47,6
47,6
I Nom. [A] 440V
75
75
37,5
37,5
43,2
43,2
I Max. [A] 440V
Compressor
Motor (cada)
Modulo Ventilação
I Nom. Total [A] I Máx. Total [A]
Fusível Total
16240
16240
16240
16240
[W]
2
2
2
2
1
1
1
1
Compressor 1
18230
18230
18230
18230
[W]
[W]
3,77
3,77
2,18
2,18
[W]
1,89
1,89
FLA [A] 440V
962
6
10
10
6
26,3
16
13,6
13,1
8
6,8
5,8
15,2
9,2
7,9
6,7
FLA [A] 440V
11,6
Condensadora 38ABA390
962
962
962
5
5
4
4
[W]
8642
8642
5243
5243
4301
4301
3625
3625
30,8
41,0
[W]
41,2
56,8
49,3
98,5
35,6
71,1
34,6
40,0
440V
69,1
26806
26806
23407
23407
17025
17025
16349
16349
Motor (cada)
54,4
47,0 108,8 62,8
40,7
81,4
35,6
71,1
26,8
53,1
25,8
29,6
440V
51,1
28796
28796
25397
25397
18425
18425
17749
17749
80
63
80
80
63
63
Modulo Ventilação
160
125
63
63
440V
100
80
16,2
16,2
18,5
18,5
50
50
28,9
10800
10800
10800
10800
Compressor 1
25
25
28,9
I Max. [A] 440V
[W]
12200
12200
12200
12200
32
32
[W]
16,2
16,2
50
50
25
25
28,9
28,9
I Max. [A] 440V
10800
10800
10800
10800
Condensadora 38ABA480
18,5
18,5
I Nom. [A] 440V
12200
12200
12200
12200
2
2
2
2
[W]
1
1
1
1
[W]
3,77
1,89
1,89
2,18
2,18
FLA [A] 440V
3,77
962
962
962
962
47,6
47,6
Motor (cada)
1
1
1
1
23,8
23,8
27,4
27,4
I Nom. [A] 440V
75
75
43,2
43,2
16240
16240
16240
16240
18230
18230
18230
18230
Modulo Ventilação
37,5
37,5
I Max. [A] 440V
16,2
16,2
18,5
18,5
50
50
25
25
28,9
28,9
I Max. [A] 440V
I Nom. Total [A] I Máx. Total [A]
32
32
I Nom. [A] 440V
Compressor 2
10800
10800
10800
10800
12200
12200
12200
12200
2
1
1
1
1
Fusível Total
2
2
2
1
1
1
1
1
1
47,6
47,6
47,6
23,8
23,8
23,8
27,4
27,4
27,4
I Nom. [A] 440V
75
75
75
37,5
37,5
37,5
43,2
43,2
43,2
I Max. [A] 440V
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
47,6
47,6
47,6
23,8
23,8
23,8
27,4
27,4
27,4
I Nom. [A] 440V
75
75
75
37,5
37,5
37,5
43,2
43,2
43,2
I Max. [A] 440V
Compressor 2
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
2
2
2
2
2
2
2
2
2
2
2
2
6,9
6,9
6,9
3,5
3,5
3,5
4
4
4
FLA [A] 440V
2051
2051
2051
2051
15
15
15
15
2051 12,5
2051 12,5
38
38
32
19
19
16
22
22
18,5
FLA [A] 440V
440V
70,6
98,0
73,6
101,0
12453
73,6
101,0
12453 147,0 84,8 201,8 116,4
12453
12453 147,0 84,8 201,8 116,4
10487
10487 141,0 81,3 195,8 112,9
440V
49035
49035
49035
49035
47069
47069
53015
53015
53015
53015
51049
51049
225
225
225
125
125
125
160
160
160
440V
Potência Potência Recomendado
Nominal Máxima
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
FLA [A] FLA [A]
FLA [A] FLA [A]
Qtde.
220V 380V 220V 380V
Total [W] Total [W] 220V 380V
220V
380V
220V
380V Pot. Nom. Pot . Max. 220V
380V
220V
380V Pot. Nom. Pot . Max. Qtde. CV 220V 380V Pot. [W] CV 220V 380V Pot. [W]
32
32
I Nom. [A] 440V
Compressor 2
I Nom. Total [A] I Máx. Total [A]
Fusível Total
3,77
3,77
1,89
1,89
2,18
2,18
FLA [A] 440V
962
962
962
962
12,5
12,5
7,5
7,5
10
10
7,5
7,5
32
19,9
26,3
19,9
16
9,95
13,1
9,95
18,5
11,5
15,2
11,5
FLA [A] 440V
63,7
49,3
66,9
56,6 133,8 77,4
46,1
97,8
440V
52,9 127,4 73,7
440V
91,4
53,7
76,2
10487
59,8
82,3
10487 119,1 68,8 164,5 95,0
6249
6249 107,0 61,8 152,4 88,0
8642
8642
6249
6249
39451
39451
35213
35213
32166
32166
29773
29773
42841
42841
38603
38603
34966
34966
32573
32573
200
200
160
160
100
100
80
80
125
100
100
100
440V
Potência Potência Recomendado
Nominal Máxima
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
FLA [A] FLA [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
FLA [A] FLA [A]
FLA [A] FLA [A]
Qtde.
380V Qtde.
220V 380V 220V 380V Total [W] Total [W] 220V 380V
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
220V
380V
220V
380V
220V
380V
220V
380V
220V
380V
220V
380V
220V
380V
220V
380V
Qtde. CV 220V 380V Pot. [W]
Qtde. CV 220V 380V Pot. [W] CV 220V 380V Pot. [W]
Tensão
220
220
220
220
380V
440V
220V
Motor (cada)
Potência Potência Recomendado
Nominal Máxima
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
FLA [A] FLA [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
FLA [A] FLA [A]
FLA [A] FLA [A]
Qtde.
Qtde.
220V
380V
220V
380V
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
Total [W] Total [W] 220V 380V
220V
380V
220V
380V
220V
380V
220V
380V
Qtde. CV 220V 380V Pot. [W]
Qtde. CV 220V 380V Pot. [W] CV 220V 380V Pot. [W]
Condensadora 38ABA150
Compressor
NOTA: . Os motores dos ventiladores são trifásicos;
. A variação da voltagem deve ser no máximo ±10%;
. A bitola do alimentador da unidade será dimensionada da seguinte forma:
- Multiplicar por 1,25 a corrrente máxima (Cor. Máx.) do maior compressor do conjunto;
- Somar a corrente máxima dos demais compressores e motores dos ventiladores do evaporador e condensadores do conjunto;
- Os cabos deverão ser classe 105 OC ou superior;
. Dados nominais obtidos na avaliação ARI 210.
. As unidades condensadoras 38AB líder sempre serão as com maior capacidade de refrigeração;
. Em uma unidade 38AB com 2 (dois) compressores, o circuito 1 sempre será o de maior capacidade de refrigeração.
40MZB480446VH
40MZB480236VH
40MZB480446VSA
40MZB480236VSA
40MZB480446VS
40MZB480236VS
Modelo
40MZB390446VH
40MZB390236VH
40MZB390446VS
40MZB390236VS
40MZB300446VH
40MZB300236VH
40MZB300446VS
40MZB300236VS
Modelo
40MZB240446VH
40MZB240236VH
40MZB240446VS
40MZB240236VS
40MZB150446VH
40MZB150236VH
40MZB150446VS
40MZB150236VS
Modelo
Tensão
14
440
440
440
380
380
380
440
440
440
380
380
380
440
440
440
380
380
380
1
1
1
1
1
1
Qtde.
1
1
1
1
1
1
Qtde.
1
1
1
1
1
1
Qtde.
16,2
16,2
16,2
18,5
18,5
18,5
28,9
28,9
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
Condensadora 38ABA240
25
25
25
28,9
Compressor
50
50
50
2
2
2
2
2
2
1
1
1
1
1
1
CV
23,8
23,8
23,8
27,4
27,4
27,4
43,2
43,2
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
Condensadora 38ABA150
37,5
37,5
37,5
43,2
Compressor
75
75
75
2
2
2
2
2
2
32
32
32
16,2
16,2
16,2
18,5
18,5
18,5
28,9
28,9
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
Condensadora 38ABA240
25
25
25
28,9
Compressor
50
50
50
2
2
2
2
2
2
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Pot. Nom. Pot . Max.
220V
380V
220V
380V
Qtde.
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
47,6
47,6
47,6
1
1
1
1
1
1
CV
1
1
1
1
1
1
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Pot. Nom. Pot . Max.
220V
380V
220V
380V
Qtde. CV
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
32
32
32
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Pot. Nom. Pot . Max.
220V
380V
220V
380V
Qtde.
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
220
220
220
440
440
440
380
380
380
1
1
1
1
1
1
47,6
47,6
47,6
23,8
23,8
23,8
27,4
27,4
27,4
75
75
75
37,5
37,5
37,5
43,2
43,2
43,2
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
2
2
2
2
2
2
1
1
1
1
1
1
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
220V 380V Qtde.
Pot. Nom. Pot . Max.
220V
380V
220V
380V
Qtde. CV
[W]
[W]
440V
I Nom. [A] 440V
I Max. [A] 440V
Tensão
220
220
220
380V
440V
220V
Tensão
220
220
220
380V
440V
220V
Tensão
220
220
220
380V
440V
220V
Condensadora 38ABA150
Compressor
Compressor 1
Compressor 2
Condensadora 38ABA390
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
1
1
1
1
1
1
47,6
47,6
47,6
23,8
23,8
23,8
27,4
27,4
27,4
37,5
37,5
37,5
43,2
43,2
43,2
Compressor 1
75
75
75
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
16,2
16,2
16,2
18,5
18,5
18,5
50
50
50
25
25
25
28,9
28,9
28,9
Compressor 2
Condensadora 38ABA300
32
32
32
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
2
2
2
2
2
2
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
1
1
1
1
1
1
32
32
32
16,2
16,2
16,2
18,5
18,5
18,5
25
25
25
28,9
28,9
28,9
Compressor 1
50
50
50
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
16,2
16,2
16,2
18,5
18,5
18,5
50
50
50
25
25
25
28,9
28,9
28,9
Compressor 2
Condensadora 38ABA480
32
32
32
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
2
2
2
2
2
2
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
1
1
1
1
1
1
47,6
47,6
47,6
23,8
23,8
23,8
27,4
27,4
27,4
37,5
37,5
37,5
43,2
43,2
43,2
Compressor 1
75
75
75
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
23,8
23,8
23,8
27,4
27,4
27,4
75
75
75
37,5
37,5
37,5
43,2
43,2
43,2
Compressor 2
Condensadora 38ABA390
47,6
47,6
47,6
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
2
2
2
2
2
2
3,77
3,77
3,77
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
1
1
1
1
1
1
47,6
47,6
47,6
23,8
23,8
23,8
27,4
27,4
27,4
75
75
75
37,5
37,5
37,5
43,2
43,2
43,2
16240
16240
16240
16240
16240
16240
18230
18230
18230
18230
18230
18230
32
32
32
16,2
16,2
16,2
18,5
18,5
18,5
50
50
50
25
25
25
28,9
28,9
28,9
10800
10800
10800
10800
10800
10800
12200
12200
12200
12200
12200
12200
2
2
2
2
2
2
FLA [A] FLA [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Qtde.
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
220V
380V Pot. [W]
220V
380V
220V
380V
220V
380V
220V
380V
Qtde.
[W]
[W]
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
I Nom. [A] 440V
I Max. [A] 440V
FLA [A] 440V
Motor (cada)
3,77
3,77
3,77
FLA [A] FLA [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Qtde.
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
220V
380V Pot. [W]
220V
380V
220V
380V
220V
380V
220V
380V
Qtde.
[W]
[W]
[W]
[W]
FLA [A] 440V
I Nom. [A] 440V
I Max. [A] 440V
I Nom. [A] 440V
I Max. [A] 440V
Motor (cada)
3,77
3,77
3,77
FLA [A] FLA [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Qtde.
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
220V
380V Pot. [W]
220V
380V
220V
380V
220V
380V
220V
380V
Qtde.
[W]
[W]
[W]
[W]
I Nom. [A] 440V
I Max. [A] 440V
I Nom. [A] 440V
I Max. [A] 440V
FLA [A] 440V
Motor (cada)
3,77
3,77
3,77
FLA [A] FLA [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
I Nom. [A] I Nom. [A] I Max. [A] I Max. [A]
Qtde.
Pot. Nom. Pot . Max.
Pot. Nom. Pot . Max.
220V
380V Pot. [W]
220V
380V
220V
380V
220V
380V
220V
380V
Qtde.
[W]
[W]
[W]
[W]
FLA [A] 440V
I Nom. [A] 440V
I Max. [A] 440V
I Nom. [A] 440V
I Max. [A] 440V
Motor (cada)
NOTA: . Os motores dos ventiladores são trifásicos;
. A variação da voltagem deve ser no máximo ±10%;
. A bitola do alimentador da unidade será dimensionada da seguinte forma:
- Multiplicar por 1,25 a corrrente máxima (Cor. Máx.) do maior compressor do conjunto;
- Somar a corrente máxima dos demais compressores e motores dos ventiladores do evaporador e condensadores do conjunto;
- Os cabos deverão ser classe 105 OC ou superior;
. Dados nominais obtidos na avaliação ARI 210.
. As unidades condensadoras 38AB líder sempre serão as com maior capacidade de refrigeração;
. Em uma unidade 38AB com 2 (dois) compressores, o circuito 1 sempre será o de maior capacidade de refrigeração.
40MZB630446VH
40MZB630236VH
40MZB630446VSA
40MZB630236VSA
40MZB630446VS
40MZB630236VS
Modelo
40MZB630446VH
40MZB630236VH
40MZB630446VSA
40MZB630236VSA
40MZB630446VS
40MZB630236VS
Modelo
40MZB540446VH
40MZB540236VH
40MZB540446VSA
40MZB540236VSA
40MZB540446VS
40MZB540236VS
Modelo
40MZB540446VH
40MZB540236VH
40MZB540446VSA
40MZB540236VSA
40MZB540446VS
40MZB540236VS
Modelo
Tensão
1
1
1
1
1
1
CV
2
2
2
2
2
2
CV
1
1
1
1
1
1
CV
1
1
1
1
1
1
CV
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
3,5
3,5
3,5
4
4
4
2051
2051
2051
2051
2051
2051
3,77
3,77
3,77
1,89
1,89
1,89
2,18
2,18
2,18
962
962
962
962
962
962
FLA [A] FLA [A]
220V
380V Pot. [W]
FLA [A] 440V
Motor (cada)
6,9
6,9
6,9
FLA [A] FLA [A]
220V
380V Pot. [W]
FLA [A] 440V
Motor (cada)
3,77
3,77
3,77
FLA [A] FLA [A]
220V
380V Pot. [W]
FLA [A] 440V
Motor (cada)
3,77
3,77
3,77
FLA [A] FLA [A]
220V
380V Pot. [W]
FLA [A] 440V
Motor (cada)
20
20
20
20
20
20
CV
20
20
20
20
20
20
CV
20
20
20
20
15
15
CV
20
20
20
20
15
15
CV
25
25
19
28,9
28,9
22
82,8
88,8
25
25
28,9
28,9
17041
25
25
28,9
28,9
82,8
50
50
25
25
25
28,9
28,9
28,9
114,1
88,8
120,1
17041
120,1
99,6
135,8
99,6
135,8
17041
135,8
96,4
132,6
96,4
132,6
17041
96,4
132,6
17041 192,3 110,9 265,1 152,9
17041
17041 192,3 110,9 265,1 152,9
17041
17041 192,3 110,9 265,1 152,9
440V
220V
58729
58729
58729
58729
54141
54141
63519
63519
63519
63519
58931
58931
40
40
440V
50
50
50
Fusível
Recomendado
80
80
80
Fusível
Recomendado
125
125
125
40
100
100
440V
100
200
200
200
160
160
160
160
160
Fusível Total
250
250
160
440V
250
58729
58729
58729
58729
54141
54141
63519
63519
63519
63519
58931
58931
40
40
440V
50
50
50
Fusível
Recomendado
80
80
80
Fusível
Recomendado
125
125
125
40
100
100
440V
100
200
200
200
160
160
160
160
160
Fusível Total
250
250
160
440V
250
66347
66347
66347
66347
66347
66347
71727
71727
71727
71727
71727
71727
40
40
440V
50
50
50
Fusível
Recomendado
80
80
80
Fusível
Recomendado
160
160
160
40
125
125
440V
125
250
250
250
160
160
200
200
200
Fusível Total
315
315
160
440V
315
64169
64169
64169
64169
64169
64169
69549
69549
69549
69549
69549
69549
250
250
250
125
125
125
440V
160
160
160
80
80
80
40
40
40
440V
50
50
50
315
315
315
160
160
160
200
200
200
440V
Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado
Nominal Máxima
380V
Total [W] Total [W] 220V 380V 220V 380V 220V 380V
I Nom. Total [A] I Máx. Total [A]
99,6
17041 198,5 114,6 271,3 156,6
17041
17041 198,5 114,6 271,3 156,6
17041
17041 198,5 114,6 271,3 156,6
440V
220V
Fusível Total
Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado
Nominal Máxima
380V
Total [W] Total [W] 220V 380V 220V 380V 220V 380V
I Nom. Total [A] I Máx. Total [A]
88,8
17041 176,7 102,0 240,1 138,6
17041
17041 176,7 102,0 240,1 138,6
12453
FLA [A] FLA [A]
220V 380V
220V
380V Pot. [W]
FLA [A] 440V
440V
50
440V
220V
Fusível
Recomendado
Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado
Nominal Máxima
380V
Total [W] Total [W] 220V 380V 220V 380V 220V 380V
12453 164,7 95,1 228,1 131,7
Modulo Ventilação
50
50
25
28,9
120,1
I Nom. Total [A] I Máx. Total [A]
88,8
FLA [A] FLA [A]
220V 380V
220V
380V Pot. [W]
FLA [A] 440V
440V
50
120,1
17041 176,7 102,0 240,1 138,6
17041
Modulo Ventilação
50
50
19
22
114,1
17041 176,7 102,0 240,1 138,6
12453
FLA [A] FLA [A]
220V 380V
220V
380V Pot. [W]
FLA [A] 440V
440V
38
440V
12453 164,7 95,1 228,1 131,7
Modulo Ventilação
50
50
38
220V
Fusível
Recomendado
Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado
Nominal Máxima
380V
Total [W] Total [W] 220V 380V 220V 380V 220V 380V
I Nom. Total [A] I Máx. Total [A]
FLA [A] FLA [A]
220V 380V
220V
380V Pot. [W]
FLA [A] 440V
440V
Modulo Ventilação
5 - DADOS DIMENSIONAIS
C - MÓDULO DE VENTILAÇÃO 40MZB
A - UNIDADE 38MZ
Cotas
Cotas
A
B
C
D
E
F
G
H
I
J
150
1510
1836
700
700
1136
92
996
341
46
241
240
1910
1836
700
700
1136
92
996
402
46
291
Cotas
K
L
M
N
O
P
Q
R
S
T
150
1027
1375
816
736
492
422
352
105
423
495
240
1327
1775
816
736
492
422
352
105
423
495
540
630
A
3050 3150
B
1000 1000
C
1130 1260
D
375
E
2300 2300
425
F
480
480
G
76
76
H
150
150
J
561
561
K
316
316
Fig. 2c
Fig. 2a
D - MÓDULO TROCADOR DE CALOR 40MZB
B - MÓDULO DE VENTILAÇÃO 40MZB
(240/300/390/480)
Fig. 2d
Cotas
A
B
C
D
E
F
G
H
240
2170
710
875
421
1327
402
473
75
300
2000
840
1070
336
1327
402
473
75
390
2420
840
1070
425
1569
480
556
75
480
2700
1000
1130
565
1569
480
556
75
**Para insuflamento em outra posição diferente da mostrada no desenho, os bocais
dos ventiladores estarão posicionados na
distância H da borda. D e E permanecem
iguais.
Fig. 2b
15
Cotas
A
B
C
D
E
F
G
H
I
K
L
M
N
O
P
Q
R
240
2170
710
765
875
180
42
142
242
342
-
300
2000
840
895
1070
180
107
207
307
407
-
390
2420
840
895
1070
180
107
207
307
407
-
480
2700
1000
1055
1130
180
187
287
387
487
-
540
3050
1000
1055
1130
260
180
200
200
200
200
187
287
630
3150
1000
1055
1260
260
180
200
200
200
200
187
287
E - UNIDADE 38AB
Cotas 150 / 240 / 300 / 390 / 480
A
2190
B
1062
C
1065
D
1141
E
594
F
1001
G
545
H
500
J
298
K
78
L
143
M
197
N
246
P
100
Fig. 2e - Dimensões da Unidade 38AB
F - CAIXA DE MISTURA (OPCIONAL)
Altura (mm) Largura (mm) Profund. (mm) Peso (kg)
Modelo
160
ITC 18 - 40MZB 240
875
2170
820
207
ITC 20 - 40MZB 300
1070
2000
820
246
ITC 25 - 40MZB 390
1070
2420
820
337
ITC 30 - 40MZB 480
1130
2700
820
378
ITC 35 - 40MZB 540
1130
3050
820
432
ITC 40 - 40MZB 630
1260
3150
820
Damper Externo (mm) Damper Retorno (mm)
Modelo
ITC 18 - 40MZB 240
550
950
750
450
ITC 20 - 40MZB 300
750
850
750
500
ITC 25 - 40MZB 390
750
1050
750
750
ITC 30 - 40MZB 480
750
1200
750
750
ITC 35 - 40MZB 540
750
1400
750
850
ITC 40 - 40MZB 630
750
1600
750
950
Fig. 2f - Dimensões da Caixa de Mistura
16
NOTAS:
1. As conexões elétricas podem ser feitas por ambos os
lados nas unidades 38MZ e no módulo de ventilação
40MZB.
Na unidade 38AB as conexões elétricas são feitas pelo
lado direito da unidade. Recomenda-se isolar o cabo de
ligação do motor do evaporador com um conduite.
2. A conexão para drenagem pode ser feita por ambos
os lados do módulo trocador de calor 40MZB. Nas
unidades condensadoras não existem conexões para
dreno, a drenagem é feita pela parte inferior do gabinete.
3. Prever suficiente espaço para serviços de manutenção
conforme figura 4. A frente do equipamento deve
permanecer desimpedida para permitir o livre fluxo de ar
e o acesso ao interior da unidade.
4. Em caso de montagem de, vários equipamentos na
mesma área, respeitar as distâncias mínimas e arranjos
indicados na figura 5.
500
B - 38MZ
EM CIMA OU EMBAIXO
PARA MANUTENÇÃO
A - 40MZB
110
E
ÕES
)
NEX
(CO ÉTRICA
EL
MAN
600
UTE
NÇÃ
O
500
RE
500
T
E M ORN
AN O D
UT
E
EN A R
ÇÃ
O
ES E
EXÕ
CON RICA
T
ELÉ
C - 38AB
Fig. 4 - Espaços mínimos requeridos para instalação
17
1
CUL 8 0 0
A
(EX ÇÃO D
TER
E
IOR AR
)
CIR
MÓDULOS 38MZ
38MZ
38MZ
38MZ
(ESCOLHER UM DOS DOIS LADOS DA UNIDADE O OUTRO PODE FICAR ENCOSTADO NA PAREDE)
38MZ
Figura 5 - Distâncias mínimas de montagem
18
6 - PROCEDIMENTOS DE SELEÇÃO
6.1 - DADOS DE PROJETO
Capacidade Total (C.T.)
Capacidade Sensível (C.S.)
Vazão de ar no Evaporador (V)
Condições de ar na entrada do
evaporador (T.B.S.E./T.B.U.E.)
Temperatura do ar de entrada no
condensador (T.A.C.)
67000 kcal/h
50000 kcal/h
17000 m3/h
24/18OC
35OC
6.2 - FÓRMULAS
Capacidade Sensível corrigida:
C.S.C. = C.S. + [0.29 x V x (1 - B.F.) x
(T.B.S.E. - 26.7) [ KCal/h)]
onde
B.F. = Fator de By-Pass
Temperatura de bulbo seco na saída da serpentina
T.B.S.S. = T.B.S.E. - [C.S./ (0,29 x V)] Diferencial de
[C.S. / (0,29 x V)]
Temperatura (DT)
DT = T.S.C. - T.A.C.
onde
T.S.C. = Temperatura Saturada de Condensação
6.3 - PROCEDIMENTOS PARA SELEÇÃO
6.3.1 - CÁLCULO DAS CAPACIDADES
Entrar na tabela 7, com a vazão de ar e T.B.U.E.
Entrar na horizontal com a T.A.C.
C.T. = 67815 Kcal/h
C. S. = 67557 Kcal/h 40MZ 300
C.T.R. = 90555 Kcal/h
Obs.:
Se o T.B.S.E. for diferente de 26,7OC fazer a correção
do C.S.
Logo:
24 = 26,7 Portanto fazer a correção
C.S.C. =C.S. + [0,29 x V x (1 - B.F.) x (T.B.S.E. - 26,7)]
C.S. = 67557 Kcal/h
V = 17000 m3/h
B.F. = 0,07 (Tabela de selecionamento)
C.S.C = 55178 Kcal/h
Comparar C.S.C. com o dado de projeto, se for maior
ou igual estará ok. 55178 >50000
6.4 - UNIDADE SELECIONADA
40MZB 300 C.T = 67815 Kcal/h
C.S. = 67557 Kcal/h
C.T.R = 90555 Kcal/h
19
7 - TABELAS DE SELECIONAMENTO
40MZB240/38MZA240
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
16320 - 0.10
16
18
20
22
16
18
20
22
16
18
20
22
56241
59514
62879
57420
58074
61070
64460
59785
59772
62185
65513
C.S.
54207
49906
42851
35503
57420
56094
47930
39088
59785
59772
52788
42555
C.T.R.
66321
68534
72086
75730
69806
70529
73769
77444
72370
72355
74979
78580
38,5
38,9
39,5
40,1
39,1
39,2
39,8
40,4
39,5
39,5
40,0
40,6
C.T.
53028
54728
57885
61253
56140
56496
59361
62684
58323
58312
60455
63714
C.S.
53028
49180
42160
34881
56140
55194
47237
38465
58323
58312
52070
41932
C.T.R.
66250
68117
71580
75277
69663
70057
73203
76836
72048
72037
74405
77963
43,8
44,2
44,8
45,4
44,4
44,5
45,1
45,7
44,8
44,8
45,3
45,9
C.T.
51747
53191
56179
59435
54660
54899
57631
60829
56823
56822
58662
61832
C.S.
51747
48481
41486
34219
54660
54235
46567
37833
56823
56821
51343
41267
C.T.R.
66133
67749
71049
74659
69359
69628
72663
76201
71751
71750
73812
77310
T.S.C.
40
13600 - 0.07
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
54207
T.S.C.
35
10880 - 0.06
C.T.
T.S.C.
30
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
49,0
49,4
50,0
50,6
49,6
49,7
50,3
50,9
50,0
50,0
50,5
51,1
C.T.
50495
51627
54474
57580
53172
53238
55880
58900
55285
55276
56807
59869
C.S.
50495
47755
40788
33574
53172
53237
45853
37149
55285
55276
50529
40667
C.T.R.
66150
67437
70605
74071
69140
69212
72183
75547
71500
71491
73216
76634
T.S.C.
54,1
54,5
55,1
55,7
54,7
54,7
55,4
56,0
55,2
55,2
55,6
56,2
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
40MZB300/38MZA150/38MZA150
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
20400 - 0.10
20
22
16
18
20
22
16
18
20
C.T.
68023
71837
74148
78618
71639
72080
76930
80386
74516
74167
78769
C.S.
68014
62424
51595
43154
71639
67502
57597
47088
74516
73564
62366
C.T.R.
87272
89785
93650
97850
91340
91661
95725
100256
94618
93504
97185
40,1
40,7
41,3
41,9
40,7
40,1
41,5
42,2
41,3
41,1
41,6
C.T.
65060
68190
71899
75863
68893
70702
74002
78370
71728
71578
75441
C.S.
63337
60469
50999
41371
68893
69343
56681
46415
69546
71578
63273
C.T.R.
85521
88952
92914
96929
90035
91335
95325
99812
93087
93091
97114
44,9
45,9
46,5
46,8
45,9
46,2
46,5
47,3
46,1
46,4
46,8
C.T.
63490
65564
69485
74885
66768
67815
71024
77065
69358
69331
72755
C.S.
63487
58366
49857
42651
66768
67557
55622
47097
69358
69331
62367
C.T.R.
85773
87924
92058
97683
89477
90555
93824
100128
92405
92401
95944
T.S.C.
40
17000 - 0.07
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
18
T.S.C.
35
13600 - 0.06
16
T.S.C.
30
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
50,3
50,8
51,4
52,1
50,9
51,0
51,6
52,4
51,4
51,4
51,8
C.T.
61812
62943
66664
71452
66268
64728
69100
72151
66848
66892
69116
C.S.
61801
57263
48449
39762
66268
63798
55420
44130
66847
66892
59947
C.T.R.
85569
86941
90821
95714
90239
89088
93576
96707
91554
91613
93882
T.S.C.
55,2
55,6
56,3
56,8
51,9
56,0
56,5
57,3
56,3
56,4
56,8
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
20
40MZB390/38MZA150/38MZA240
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
C.T.
25
26520 - 0.11
16
18
88579
91966
20
97024
22
16
18
20
22
16
18
102149
93470
94540
99529
104788
97140
97101
88579
80868
69233
57423
93470
90690
77403
63127
97140
97100
108539
112236
117740
123299
113849
115023
120460
126171
117854
117812
39,2
39,7
40,3
40,9
39,8
40,0
40,6
41,2
40,3
40,3
86629
89410
94421
99483
91252
91989
96731
101951
94809
94793
C.S.
86629
79755
68280
56483
91251
89136
76258
62155
94808
94792
C.T.R.
108589
111635
117141
122682
113637
114456
119677
125403
117548
117525
T.S.C.
C.T.
44,5
45,0
45,6
46,2
45,1
45,2
45,9
46,5
45,6
45,5
84373
86602
91535
96577
88964
89431
93786
98813
92209
92191
C.S.
84373
78345
67064
55374
88964
87775
75100
61036
92209
92191
C.T.R.
108398
110879
116330
121907
113475
114006
118818
124390
117052
117032
T.S.C.
C.T.
40
22100 - 0.07
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
C.T.R.
C.T.
35
17680 - 0.05
C.S.
T.S.C.
30
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
49,7
50,1
50,7
51,3
50,3
50,4
51,0
51,6
50,7
50,7
82027
84004
88648
93452
86369
86680
90657
95476
89474
90258
C.S.
82027
77134
66237
54232
86369
85743
73874
59844
89474
87116
C.T.R.
108241
110464
115633
120996
113091
113433
117875
123256
116529
117413
T.S.C.
54,8
55,1
55,7
56,4
55,4
55,4
56,0
56,7
55,8
55,9
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
40MZB480/38MZA240/38MZA240
TEMPERATURADE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
35
40
27200 - 0.06
32640 - 0.13
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
18
20
22
16
C.T.
105932
109627
115763
122233
C.S.
105931
97834
83643
69239
C.T.R.
129970
133988
140680
147681
T.S.C.
30
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
21760 - 0.05
18
20
22
16
111710
112793
118918
125242
116264
116355
111710
109629
93843
76151
116264
116323
136278
137423
144081
150944
141192
141301
18
38,3
38,7
39,3
39,8
38,8
39,0
39,6
40,1
39,3
39,3
C.T.
103939
106421
113294
118983
109095
109777
115556
122135
113961
113492
C.S.
103939
96290
83179
68425
109095
107390
92421
75295
113961
113492
C.T.R.
130371
132923
140648
146688
135841
136586
142919
150143
142028
140678
T.S.C.
43,7
44,0
44,7
45,2
44,2
44,2
44,9
45,5
44,8
44,6
C.T.
101030
103397
109457
115654
106437
106936
112152
118455
110540
110493
C.S.
101030
94693
81070
66843
106436
105746
90984
73900
110540
110493
C.T.R.
129549
132184
138904
145761
135540
136095
141870
148862
140069
140017
T.S.C.
49,7
49,7
48,8
49,1
49,7
50,3
49,3
49,4
50,0
50,6
C.T.
98363
100509
106146
112186
103774
103881
108739
114707
107450
107480
C.S.
98363
93639
79821
65612
98363
93639
79821
65612
103774
103881
C.T.R.
129357
131784
138068
144829
135412
135561
140977
147645
139517
139534
T.S.C.
53,9
54,2
54,7
55,4
54,4
54,5
55,1
55,7
54,8
54,8
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
21
40MZB540/38MZA150(2x)/38MZA240
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
36720 - 0.13
16
18
20
22
16
18
20
22
16
18
127911
133488
141312
128890
129984
137820
144658
134659
135857
C.S.
122062
112183
94323
78555
128890
123435
105389
86064
134659
122952
C.T.R.
153393
158113
165521
173354
160936
161978
169274
177469
167369
166961
39,3
39,8
40,4
41,0
39,9
39,7
40,7
41,3
40,4
40,5
117935
122758
129616
136938
124871
127033
133189
140870
130279
131033
C.S.
116214
109507
93037
76153
124871
124376
103783
84770
130278
128128
C.T.R.
151573
156865
164280
171982
159490
161182
168309
176419
165536
166250
T.S.C.
C.T.
44,4
45,0
45,6
46,1
45,2
45,3
45,8
46,5
45,5
45,5
115087
118601
125500
134145
121270
122554
128488
137714
126421
126550
C.S.
115084
106708
91224
76770
121269
121633
102056
84819
126407
126540
C.T.R.
151709
155471
162895
172117
158628
159974
166270
176100
164349
164550
T.S.C.
C.T.
40
30600 - 0.07
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
122070
C.T.
35
24480 - 0.06
C.T.
T.S.C.
30
VAZÃO DE AR NO EVAPORADOR - (m3/h) - FATOR BY-PASS
49,7
50,1
50,7
51,3
50,3
50,3
50,9
51,6
50,7
50,8
112161
114421
120980
128864
119285
117811
124817
130880
123490
122483
C.S.
112150
104881
89121
73241
119285
116883
101141
81174
123490
122479
C.T.R.
151522
154177
161216
169564
159171
158095
165543
172029
164444
163422
T.S.C.
54,7
55,1
55,7
56,2
53,3
55,4
55,9
56,6
55,8
55,8
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
40MZB630/38MZA240(2x)/38MZA150
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
VAZÃO DE AR NO EVAPORADOR - (m3/h) - FATOR BY-PASS
28560 - 0.06
30
35
40
342840 - 0.13
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
25
35700 - 0.07
18
20
22
16
18
20
22
16
18
C.T.
142291
147694
155995
164456
150367
152086
160043
168661
156381
156329
C.S.
142291
130320
111695
92603,8
150367
146275
124899
101861
156381
156329
C.T.R.
174254
180143
189169
198339
183019
184909
193557
202910
189565
189509
T.S.C.
38,9
39,3
39,9
40,5
39,4
39,6
40,2
40,8
39,9
39,9
C.T.
139173
143638
151778
160179
146881
147971
155551
164064
152601
152574
C.S.
139173
128488
110058
91046,8
146881
143830
123067
100272
152601
152573
C.T.R.
174233
179130
188067
197273
182665
183874
192212
201538
188939
188904
T.S.C.
44,2
44,6
45,2
45,8
44,8
44,9
45,5
46,1
45,2
45,2
C.T.
135648
139309
147202
155471
143126
143829
150893
159088
148515
148497
C.S.
135648
126386
108174
89282,7
143126
141517
121246
98526,4
148515
148496
C.T.R.
173927
178010
186730
195885
182200
182997
190818
199896
188148
188128
T.S.C.
49,3
49,7
50,4
51,0
49,9
50,0
50,7
51,3
50,4
50,4
C.T.
132063
135161
142626
150509
139057
139432
146030
153841
144258
145029
C.S.
132062
124457
106654
87502,3
139057
138499
119312
96657,7
144258
141898
C.T.R.
173787
177284
185592
194390
18159
182012
189399
198114
187376
188249
T.S.C.
54,5
54,8
55,4
56,0
55,1
55,1
55,7
56,3
55,5
55,5
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
22
40MZB240/38ABA240
TEMPERATURADE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
16320 - 0.10
16
18
20
22
16
18
20
22
16
18
20
22
57059
60353
63616
58063
58847
61912
65281
60465
60456
63028
66341
C.S.
54909
50293
43136
35747
58063
56503
48267
39360
60465
60456
53112
42855
C.T.R.
66249
68538
72058
75542
69612
70450
73719
77321
72181
72174
74912
78442
35,7
36,1
36,6
37,1
36,2
36,4
36,9
37,5
36,6
36,6
37,1
37,7
C.T.
53754
55531
58855
62204
56893
57441
60363
63708
59178
59170
61484
64760
C.S.
53754
49631
42535
35226
56893
55740
47631
38813
59178
59170
52509
42290
C.T.R.
66169
68173
71669
75288
69558
70150
73293
76908
72019
72010
74497
78042
40,8
41,7
41,8
42,4
41,4
41,5
42,0
42,6
41,8
41,8
42,3
42,8
C.T.
52379
53956
57092
60534
55465
55732
58584
61962
57708
57630
59659
62979
C.S.
52379
48837
41838
34624
55465
54733
46898
38211
57708
57630
51747
41662
C.T.R.
66052
67806
71190
74811
69392
69699
72795
76360
71727
71732
73964
77469
T.S.C.
40
13600 - 0.07
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
54909
T.S.C.
35
10880 - 0.06
C.T.
T.S.C.
30
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
46,6
47,0
47,5
47,4
47,0
47,1
47,6
47,7
46,9
47,3
47,8
47,9
C.T.
51051
52384
55347
58615
53951
54047
56860
60091
56091
56096
57830
61004
C.S.
51051
48143
41122
33932
53951
53732
46245
37562
56091
56096
51011
40986
C.T.R.
65968
67481
70717
74276
69164
69265
72308
75727
71487
71492
73444
76884
T.S.C.
51,8
52,2
52,7
53,1
52,3
52,3
52,6
52,7
52,6
52,6
53,1
53,5
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
40MZB300/38ABA300
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
30
35
40
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
13600 - 0.06
17000 - 0.07
20400 - 0.10
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
18
20
22
16
18
C.T.
70213
73285
76830
80612
73962
75158
78830
82480
76629
76728
80063
C.S.
70213
63387
54243
44911
73962
71170
60467
49209
76629
76728
66278
C.T.R.
86226
89596
93478
97624
90331
91642
95680
99688
93252
93362
97027
T.S.C.
38,4
39,2
39,2
39,4
38,8
39,1
39,4
39,5
38,9
39,0
39,4
C.T.
68744
71355
74928
78536
72187
73203
76737
80396
74969
74929
77951
C.S.
68744
62571
53320
44074
72187
69803
59591
48447
74969
74929
65392
C.T.R.
86525
8954
93349
97301
90299
91433
95329
99363
93377
93333
96659
T.S.C.
44,1
44,9
45,2
45,5
44,6
44,9
45,4
45,7
44,9
44,9
45,5
C.T.
66987
69102
72687
76250
70281
70968
74394
78055
72964
72903
75581
C.S.
66987
61451
52375
43260
70281
68611
58645
47633
72964
72903
64332
C.T.R.
86651
88979
92935
96872
90245
91019
94808
98872
93212
93144
96126
T.S.C.
49,9
50,3
50,8
51,3
50,3
50,5
51,0
51,4
50,6
50,6
51,2
C.T.
64939
66664
70175
73700
68163
68574
71776
75333
70581
70648
72891
C.S.
64939
60081
51513
42311
68163
67003
57597
46703
70581
70647
63311
C.T.R.
86498
88433
92328
96214
90066
90543
94094
98031
92714
92830
95327
T.S.C.
55,2
55,6
56,1
56,5
55,6
55,8
56,3
56,7
55,9
56,1
56,4
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
23
20
22
16
18
20
40MZB390/38ABA390
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
C.T.
25
C.S.
C.T.R.
T.S.C.
C.T.
30
C.S.
C.T.R.
T.S.C.
C.T.
35
C.S.
C.T.R.
T.S.C.
C.T.
40
C.S.
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
17880 - 0.05
22100 - 0.07
26520 - 0.11
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
18
20
22
16
18
20
22
16
18
89802
93717
98971
104602
95022
96357
101816
107339
98926
98968
89802
81706
70042
58287
95022
91534
78308
63985
98926
98968
109288
113541
119198
125240
114914
116370
122262
128208
119119
119164
34,8
35,1
35,4
35,5
35,1
35,2
35,5
35,7
35,2
35,2
87947
91177
96494
101867
92802
93879
99049
104569
96738
96730
87947
80583
69083
57254
92802
90263
77207
62984
96738
96730
109384
112889
118672
124466
114606
115804
121419
127411
118893
118885
40,4
40,7
41,0
41,2
40,6
40,8
41,1
41,4
40,9
40,9
85886
88471
93377
99026
90602
91224
96139
101652
94255
94246
85886
79306
67909
56213
90602
89033
76143
62025
94255
94245
109344
112190
117498
123689
114488
115172
120554
126611
118460
118470
45,8
46,1
46,3
46,7
46,1
46,2
46,6
47,0
46,3
46,4
83625
85817
90840
96073
88316
88706
93163
98444
91678
91615
83625
78001
66769
55146
88316
87156
74805
60952
91677
91614
C.T.R.
109225
111663
117199
123025
114394
114849
119745
125546
118054
118120
T.S.C.
51,0
51,3
51,7
52,3
51,4
51,5
51,9
52,2
51,6
52,0
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
40MZB480/38ABA480
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
(OC)
25
30
35
40
VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS
21760 - 0.05
27200 - 0.06
32640 - 0.13
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
18
20
22
16
C.T.
18
20
22
106143
110031
116191
122755
C.S.
106143
97972
83778
69439
C.T.R.
131252
135500
142386
T.S.C.
35,4
36,0
36,3
C.T.
104065
107015
113410
119517
C.S.
104065
96547
82741
68367
C.T.R.
131314
134673
141819
148602
T.S.C.
41,2
41,9
42,5
41,2
C.T.
101612
103994
110317
C.S.
101612
94995
81490
C.T.R.
131327
134073
T.S.C.
47,5
47,9
C.T.
99190
C.S.
99190
C.T.R.
T.S.C.
111978
113089
119269
125724
116664
116591
111978
109452
93721
76352
116663
116590
149462
137715
138953
145809
153026
142719
142970
36,3
35,9
36,2
36,5
37,2
35,6
36,5
109874
110266
116873
122744
113933
113903
109873
107749
93512
75329
113933
113903
138471
138116
146340
151882
142177
142203
42,3
41,1
43,0
41,7
41,4
41,3
116489
107065
107613
113024
119394
111243
111195
67158
107065
106480
91272
74122
111243
111194
141064
147824
137394
138066
144055
151049
141999
141946
48,0
47,7
47,6
47,9
48,1
47,7
47,6
47,6
101341
107200
113363
104612
104903
109725
115930
108463
108429
93618
80207
66031
104612
104081
89970
72903
108462
108429
131505
133976
140538
147461
137627
137937
143380
150331
141872
141878
53,0
53,3
53,6
54,0
53,4
53,5
53,8
54,1
53,5
53,7
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
24
16
18
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
( OC)
25
30600 - 0.07
36720 - 0.13
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
18
20
22
16
18
20
22
16
18
129451
136658
144326
131159
133077
140544
148093
136504
136585
C.S.
123977
112523
96497
80301
131159
126120
107808
88120
136504
136585
C.T.R.
150429
156368
164137
172390
158174
160261
168329
176477
163939
164026
34,7
35,1
35,4
35,6
35,1
35,2
35,5
35,8
35,2
35,2
C.T.
121393
126001
133231
140594
128094
129658
136746
144293
133464
133469
C.S.
121393
111002
95141
78884
128093
124284
106300
86733
133464
133469
C.T.R.
150544
155540
163408
171362
157763
159491
167196
175397
163613
163619
40,2
40,5
40,9
41,2
40,5
40,7
41,0
41,4
40,8
40,8
118563
122244
128708
136654
125004
125932
132711
140256
130064
130050
C.S.
118563
109245
93419
77432
125004
122857
104777
85390
130063
130049
C.T.R.
150527
154563
161534
170260
157545
158564
165975
174259
163049
163054
C.T.
45,5
45,8
46,1
46,6
45,9
46,0
46,4
46,9
46,2
46,2
115309
118407
125316
132494
121759
122374
128517
135737
126401
126301
C.S.
115309
107353
91875
75931
121759
119971
102917
83833
126400
126301
C.T.R.
150221
153651
161253
169287
157319
158022
164758
172687
162377
162506
T.S.C.
50,7
51,0
51,4
52,2
51,1
51,2
51,6
52,1
51,4
51,9
T.S.C.
C.T.
40
24480 - 0.06
123977
T.S.C.
35
Vazão de Ar no Evaporador - ( m3/h) - Fator de By-Pass
C.T.
T.S.C.
30
40MZB540/38ABA390/38ABA150 e 40MZA540/38ABA300/38ABA240
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
TEMPERATURA DE
ENTRADA
DO AR DE
CONDENSAÇÃO
( OC)
25
30
35
40
40MZB630/38ABA390/38ABA240 e 40MZA630/38ABA480/38ABA150
Vazão de Ar no Evaporador - ( m3/h) - Fator de By-Pass
28560 - 0.06
35700 - 0.07
42840 - 0.13
TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC)
16
18
20
22
16
18
20
22
16
18
C.T.
143705
149899
158355
C.S.
143705
131034
112291
167473
152083
154144
162951
171865
158378
158421
93445
152083
146733
125620
102612
158378
158421
C.T.R.
175349
182085
T.S.C.
34,9
35,2
191180
200939
184375
186626
196121
205701
191143
191191
35,4
35,4
35,1
35,2
35,4
35,5
35,1
35,1
C.T.
140761
C.S.
140761
145777
154400
163052
148532
150176
158500
167409
154894
154866
129206
110787
91783
148532
144782
123846
101017
154894
154866
C.T.R.
T.S.C.
175520
180968
190340
199659
183869
185708
194743
204404
190798
190767
40,6
40,8
41,1
41,3
40,7
40,9
41,2
41,4
41,0
41,0
C.T.
137446
141467
149635
158523
145063
145990
153862
162751
150895
150881
C.S.
137446
127155
109012
90131
145063
142533
122197
99500
150895
150879
C.T.R.
175417
179860
188723
198447
183735
184753
193385
203156
190068
190095
T.S.C.
46,0
46,3
46,5
46,9
46,3
46,4
46,8
47,1
46,5
46,6
C.T.
133965
137398
145461
153885
141497
142043
149186
157709
146876
146789
C.S.
133965
125161
107159
88454
141497
139832
120072
97860
146875
146788
C.T.R.
175372
179208
188107
197440
183683
184335
192192
201557
189534
189600
T.S.C.
51,3
51,6
52,0
52,5
51,6
51,8
52,1
52,4
51,8
52,1
C.T. - Capacidade Total ( kcal/h)
C.S. - Capacidade Sensível (kcal/h)
C.T.R. - Calor Total Rejeitado ( kcal/h)
T.S.C. - Temperatura Saturada de Condensação (°C)
25
8 - CURVAS DE VAZÃO
8.1 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 240
* Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos.
8.2 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 300
* Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos.
26
8.3 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 390
* Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos.
8.4 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 480
* Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos.
27
8.5 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 540
* Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos.
8.6 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 630
* Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos.
28
9 - DADOS PARA INSTALAÇÃO
DIÂMETRO DA LINHA
Circuito 150
1 3/8” ATÉ 18m
1 5/8” ACIMA DE 18m
DE SUCÇÃO
Circuito 240
1 5/8” ATÉ 18m
2” ACIMA DE 18m
DIÂMETRO DA LINHA
Circuito 150
5/8” ATÉ 24m
3/4” ACIMA DE 24m
DE LÍQUIDO
Circuito 240
5/8” ATÉ 10m
7/8” ACIMA DE 10m
COMPRIMENTO MÁXIMO TUBULAÇÃO
30m (COMPRIMENTO EQUIVALENTE POR CIRCUITO)
DESNÍVEL MÁXIMO ENTRE UNIDADES
15m
CARGA DE REFRIGERANTE
40MZB240 - 38MZA240 12,7kg
CONDENSADORA + EVAPORADORA
40MZB300 - 38MZA150 8,1kg
- 38MZA150 8,1kg
40MZB390 - 38MZA150 8,8kg
- 38MZA240 12,9kg
40MZB480 - 38MZA240 13,5kg
- 38MZA240 13,5kg
40MZB540 - 38MZA150 8,4kg
- 38MZA150 8,4kg
- 38MZA240 12,8kg
40MZB630 - 38MZA150 8,2kg
- 38MZA240 12,8kg
- 38MZA240 12,8kg
40MZB240 - 38ABA240 9,2kg
40MZB300 - 38ABA300 7,6/7,6kg (Circ. 150/ Circ.150)
40MZB390 - 38ABA390 8,7/11,6kg (Circ. 150/ Circ. 240)
40MZB480 - 38ABA480 9,8/9,8kg (Circ. 240/ Circ. 240)
40MZB540 - 38ABA150 + 38ABA390 8,2/ 8,2/ 12,6kg (Circ. 150/ Circ. 150/ Circ. 240)
- 38ABA240 + 38ABA300 12,6/ 8,2/ 8,2kg (Circ. 240/ Circ. 150/ Circ. 150)
40MZB630 - 38ABA150 + 38ABA480 7,9/ 11,9/ 11,9kg (Circ. 150/ Circ. 240/ Circ. 240)
- 38ABA240 + 38ABA390 11,9/ 11,9/ 7,9kg (Circ. 240/ Circ. 240/ Circ. 150)
ACRÉSCIMO DE GÁS
200g A MAIS PARA CADA METRO DE TUBULAÇÃO POR CIRCUITO
ACRÉSCIMO DE ÓLEO
ACIMA DE 20m ACRESCER ÓLEO NA RAZÃO DE 1 A 2% EM PESO DA CARGA DE REFRIGERANTE
ESTES VALORES SÃO APENAS PARA REFERÊNCIA DEVENDO A CARGA DE GÁS SER VERIFICADA PELAS MEDIÇÕES DE SUB-RESFRIAMENTO E SUPERAQUECIMENTO.
10 - TABELA DE UTILIZAÇÃO DAS CONDENSADORAS
As unidades 40MZB(V+T) podem ser utilizadas com condensadoras remotas com ventilador centrífugo ou axial segundo as combinações
abaixo.
Evaporadora
Vent. Centrifugo
Evaporadora
40MZB (V+T)
38MZ150
240
38MZ240
38AB150
38AB240
1
300
2
390
1
480
540
Condensador Vent Axial
38AB300
38AB390
1
1
1
1
2
2
38AB480
1
540
-
-
630
1
2
630
-
-
1
1
1
1
1
1
1
1
29
1
11 - TABELA DE DISPONIBILIDADE DE ITENS POR PADRÃO DE ESPECIFICAÇÕES
ITEM
PADRÃO
STANDARD - S
COMPRESSORES SCROLL
D
FILTRAGEM G2 DE FIBRA 1”
D
BANDEJA DE CONDENSADO EM CHAPA DE AÇO
D
TERMOSTATO COM CHAVE DE ACIONAMENTO
O
PRESSOSTATO MINIATURIZADO NO LADO DE ALTA E BAIXA
D
FILTRO DE SUCÇÃO (SÓLIDOS) NA ENTRADA DO COMPRESSOR
D
QUADRO ELÉTRICO
D
VÁLVULAS 1/4” SERVIÇOS NAS L. SUCÇÃO, LÍQUIDO E DESCARGA
D
FILTRO SECADOR
D
VÁLVULA DE EXPANSÃO TERMOSTÁTICA
D
CLO-RELÉ ANTICICLAGEM
D
ACIONAMENTO P/ AQUECIMENTO
O
CAIXA DE MISTURA
O
D - DISPONÍVEL
N - NÃO DISPONÍVEL
O - OPCIONAL
30
A critério da fábrica, e tendo em vista o aperfeiçoamento do produto, as características daqui constantes poderão ser alteradas a qualquer momento sem aviso prévio.
www.carrierdobrasil.com.br
CT 40MZB 240 a 630 - K - 05/09
Download

do Manual - thermogyn ar condicionado