Multisplit Alta Capacidade MÓDULO DE VENTILAÇÃO 40MZB MÓDULO TROCADOR DE CALOR 40MZB UNIDADE CONDENSADORA 38AB UNIDADE CONDENSADORA 38MZ Catálogo Técnico Índice 1 INTRODUÇÃO ...................................................................................... 3 2 CARACTERÍSTICAS GERAIS .............................................................. 4 2.1 UNIDADE CONDENSADORA 38MZ .............................................. 4 2.2 UNIDADE CONDENSADORA 38AB .............................................. 4 2.3 MÓDULO DE VENTILAÇÃO 40MZB ............................................. 6 2.4 MÓDULO TROCADOR DE CALOR 40MZB ................................... 7 2.5 MÓDULO CAIXA DE MISTURA (OPCIONAL) ................................. 8 3 4 5 6 7 8 CARACTERÍSTICAS TÉCNICAS GERAIS ........................................... 9 DADOS ELÉTRICOS .......................................................................... 12 DADOS DIMENSIONAIS .................................................................... 15 PROCEDIMENTOS DE SELEÇÃO ..................................................... 19 TABELAS DE SELECIONAMENTO .................................................... 20 CURVAS DE VAZÃO .......................................................................... 26 8.1 MÓDULO DE VENTILAÇÃO 240 ................................................. 26 8.2 MÓDULO DE VENTILAÇÃO 300 ................................................. 26 8.3 MÓDULO DE VENTILAÇÃO 390 ................................................. 27 8.4 MÓDULO DE VENTILAÇÃO 480 ................................................. 27 8.5 MÓDULO DE VENTILAÇÃO 540 ................................................. 28 8.6 MÓDULO DE VENTILAÇÃO 630 ................................................. 28 9 DADOS PARA INSTALAÇÃO ............................................................. 29 10 TABELA DE UTILIZAÇÃO DAS CONDENSADORAS ......................... 29 11 TABELA DE DISPONIBILIDADE DE ITENS....................................... 30 1 - INTRODUÇÃO A Carrier, sempre buscando ampliar as opções dos nossos clientes e oferecendo o que há de melhor no mercado, estende a sua consagrada linha de Multisplit para as capacidades de 240, 300, 390, 480, 540 e 630000 Btu/h. 2. CARACTERÍSTICAS GERAIS RECOLHIMENTO DE CONDENSADO GABINETES A bandeja de recolhimento do condensado do evaporador 40MZ é em chapa de aço. Desenhada para proporcionar drenagem 100% positiva, evitando assim corrosão. 40 MZB As evaporadoras são construídas em chapas de aço galvanizado e com revestimento de poliestireno expandido interno. As evaporadoras 240/300/390/480/540/630 são formadas pelos módulos trocador de calor e ventilação fornecidos separadamente. Os painéis de fechamento são facilmente removíveis para acesso aos componentes internos. Acompanham a máquina chaves de abertura para os painéis, facilitando a manutenção do equipamento. 2.1. UNIDADE CONDENSADORA 38MZ Condensação a ar, compressor(es) SCROLL e quadro elétrico incorporado. REFRIGERAÇÃO E AQUECIMENTO Os equipamentos podem refrigerar ou aquecer os ambientes, desde que instalados com resistências de aquecimento, fornecidas opcionalmente por nossos instaladores credenciados. O fornecimento e a instalação de acessórios deverão ser feitos pelo instalador credenciado de sua escolha, garantindo assim o perfeito funcionamento das unidades. 38MZ / 38AB Construídos sobre estrutura de chapas de aço galvanizado e fosfatizadas, os gabinetes das unidades condensadoras 38MZ e 38AB são revestidos por processo de pintura a pó poliester em tons de cinza, com posterior secagem em estufa. Os painéis de fechamento são facilmente removíveis, permitindo total acesso aos componentes internos. NOMENCLATURA 38MZ 38 MZ A 150 22 6 S UNIDADE CONDENSADORA PADRÃO DE ESPECIFICAÇÕES S - STANDARD VENTILADOR CENTRÍFUGO FREQÜÊNCIA NOMINAL 6 - 60Hz IDENTIFICAÇÃO NA ALTERAÇÃO DO PROJETO MODELO 150 240 22 - 220V TENSÃO NOMINAL 38 - 380V 44-440V 2.2. UNIDADE CONDENSADORA 38AB NOMENCLATURA 38AB 38 AB A 240 22 6 UNIDADE CONDENSADORA S PADRÃO DE ESPECIFICAÇÕES S - STANDARD VENTILADOR AXIAL FREQÜÊNCIA NOMINAL 6 - 60Hz IDENTIFICAÇÃO NA ALTERAÇÃO DO PROJETO 22 - 220V MODELO 150 / 240 / 300 / 390 / 480 4 TENSÃO NOMINAL 38 - 380V 44-440V POSIÇÕES DE MONTAGEM DA UNIDADE CONDENSADORA 38MZ ! IMPORTANTE As unidades 38AB e 38MZ possuem resistências de cárter nos compressores. Certifique-se de que todos os compressores estejam aquecidos antes de partir. OS AQUECEDORES DE CÁRTER DEVERÃO SER ENERGIZADOS 24 HORAS ANTES DA PARTIDA. OS AQUECEDORES DEVERÃO SER ENERGIZADOS SEMPRE QUE A UNIDADE NÃO ESTIVER EM OPERAÇÃO. Entretanto, durante uma parada prolongada para manutenção, os aquecedores poderão ser desenergizados. Quando for restabelecida a operação normal, os aquecedores de cárter deverão permanecer energizados previamente durante 24 horas antes da partida da unidade. A B C A - Montagem de fábrica. / B e C - Conversão em campo. QUADRO ELÉTRICO OBS.: A Carrier não se responsabiliza por problemas decorrentes da instalação das unidades em posição de montagem que não sejam as acima indicadas. Montado em fábrica nas unidades condensadoras, e com uma tensão de comando de 24V-1ph-60Hz, o quadro elétrico foi projetado para a mais absoluta segurança, possuindo fusíveis de controle, contactores, relés de sobrecarga e CLO. As conexões elétricas podem ser feitas por ambos os lados nas unidades 38MZ e no lado direito das unidades 38AB. COMPRESSOR SCROLL As unidades 38MZ / 38AB são equipadas com compressor Scroll que proporcionam maior eficiência energética, menor nível de ruído e, especialmente, aumento de confiabilidade do principal componente do sistema de refrigeração. PADRÃO DE ESPECIFICAÇÕES STANDARD (S) - Pressostatos de alta e baixa, individuais, do tipo miniaturizado e rearme automático; - Filtro secador; - Filtro de sucção; - Válvulas de serviço 1/4" para tomada de pressão, vácuo e carga de refrigerante nas linhas sucção descarga e líquido; DISPOSITIVOS DE PROTEÇÃO DO COMPRESSOR SCROLL • LINE BREAK E TERMOSTATO INTERNO- Dispositivo montado internamente no estator do motor do compressor scroll com a finalidade de proteger contra sobrecarga e superaquecimento. COMANDOS • CLO (compressor lock-out) - Componente instalado no quadro elétrico das condensadoras com a finalidade de evitar a ciclagem automática do compressor. Após a atuação dos pressostatos de alta ou baixa, do Line Break ou do termostato interno, o rearme só é possível desligando e religando a unidade no termostato ou chave ON-OFF. Esta característica garante que os elementos de proteção funcionem como sendo de rearme manual através do painel elétrico. Visando oferecer ao usuário um maior número de opções, a Carrier disponibilizou em forma de Kits os comandos Eletromecânicos, o controlador microprocessado Temp System com ou sem relógio e o comando Digital Carrier Programável e Não Programável listados abaixo: - CKTMFR1A - CKTMFR2A - CKTMFR3A - CKDCST1A Kit comando Eletromecânico para 1 estágio Kit comando Eletromecânico para 2 estágios Kit comando Eletromecânico para 3 estágios Kit comando Digital Carrier Não Programável para 1 estágio. - CKDCST2A - Kit comando Digital Carrier Não Programável para 2 estágios. - CKDCPG1A - Kit comando Digital Carrier Programável para 1 estágio. - CKDCPG2A - Kit comando Digital Carrier Programável para 2 estágios. • RESISTÊNCIA DE AQUECIMENTO DO CÁRTER Todas as unidades condensadoras 38AB 150 até 38AB 480 e as unidades condensadoras 38MZ 150 e 38MZ 240 saem da fábrica equipadas com resistência de cárter. O uso da resistência de cárter é para previnir o acúmulo de líquido refrigerante no óleo durante as paradas do equipamento. Certifique-se que os aquecedores estão firmemente presos para evitar que se desloquem. O aquecedor tem sua fiação interligada ao painel nos contatos normalmente fechados do contator de força, para que seja energizado quando houver parada do compressor. - Estes Kits são amplamente descritos em literatura específica. ! AVISO Os aquecedores do cárter estão ligados no circuíto de controle. Por, isso estarão sempre energizados mesmo que a máquina esteja DESLIGADA. 5 VENTILADORES As características do DIGITAL CARRIER não programável são: - display de cristal líquido; - controla os seguintes modos de operação: refrigeração, aquecimento, desumidificação, ventilação, ou totalmente automático; - timer 24 horas com sensor integrado de temperatura. As unidades condensadoras 38MZ possuem ventiladores do tipo centrífugo, de dupla aspiração, com pás voltadas para a frente (sirocco) e voluta em chapa de aço galvanizado, dinâmica e estaticamente balanceados, unidos através de eixo com mancais auto lubrificantes, auto compensadores e blindados, os mesmos são acoplados a motor trifásico através de transmissão por correia e polia. As unidades 38AB possuem ventiladores axiais, dinâmica e estaticamente balanceados, acoplados diretamente ao motor trifásico. As características do DIGITAL CARRIER programável são: - programação semanal com 4 períodos individuais por dia para cada zona condicionada; - range individual de 13°C a 32°C de temperatura para cada zona; - modo de operação individual para cada zona; - modo de distribuição de ar individual para cada zona; - programação de feriados; - relógio; - indicador das condições de filtro; - indicador de falhas; - display de cristal líquido. SERPENTINA CONDENSADORA Serpentinas de 2, 3 ou 4 filas (conforme modelo), de tubos de cobre grooved, com diâmetro 3/8" expandidos contra aletas do tipo Gold Fin (resistentes à corrosão), testados quanto a resistência mecânica e vazamentos a 420 psig e dotados de circuito de sub-resfriamento. Nos Kits são enviados o painel de controle e também a placa de relés, necessários para comandar compressor/ ventilador da unidade. Eles devem ser montados em campo observando que a placa de relés eletrônicos (Relay Pack) seja montada externamente à unidade, evitandose interferências eletromagnéticas, e que o painel deve ser instalado junto ao ambiente a ser condicionado. As conexões de refrigerante são para solda e estão localizadas à esquerda da serpentina na unidade 38MZ e à direita na unidade 38AB, podendo sair para os dois lados em ambas as unidadades. 2.3. MÓDULO DE VENTILAÇÃO 40MZB 40 MZ B 300 23 6 VS H1 H1 - montagem horiz./descarga horiz. H2 - montagem horiz./descarga superior/inferior V1 - montagem vert./ descarga vertical V2 - montagem vert./descarga frontal/traseira MÓDULO DE VENTILAÇÃO VS / VA / VH FAIXA DE PRESSÕES - VER ITEM 3 MULTISPLIT ALTA CAPACIDADE IDENTIFICAÇÃO NA ALTERAÇÃO DO PROJETO FREQUÊNCIA NOMINAL 6 - 60Hz CAPACIDADE NOMINAL 240/300/390/480/540/630 23 - 220/380V TENSÃO NOMINAL 44-440V MOTOR E VENTILADOR Os módulos de ventilação 40MZB utilizam ventiladores centrífugos de dupla aspiração com pás voltadas para a frente (Sirocco). Possuem rotor em aço galvanizado, dinâmica e estaticamente balanceados, acionados por motor elétrico e transmissão por correia e polia ajustável para diferentes combinações de vazão / pressão disponível (ver curvas de operação). O módulo de ventilação 40MZB é fornecido avulso, devendo ser montado em conjunto com um módulo trocador de calor 40MZB de capacidade nominal igual de modo a formar uma unidade evaporadora para a aplicação desejada. 6 2.4. MÓDULO TROCADOR DE CALOR 40MZB Trocador de calor de expansão direta tipo aletas e tubos com válvula de expansão termostática. 40 MZ B 300 T V MÓDULO TROCADOR DE CALOR V - montagem vertical H - montagem horizontal MULTISPLIT ALTA CAPACIDADE TROCADOR DE CALOR IDENTIFICAÇÃO NA ALTERAÇÃO DO PROJETO CAPACIDADE NOMINAL 240/300/390/480/540/630 FILTROS DE AR O módulo trocador de calor 40MZB é fornecido com filtros padrão G2, de 1 polegada de espessura. Os filtros são de fácil remoção e limpeza. POSIÇÕES DE MONTAGEM DO MÓDULO TROCADOR DE CALOR EM CONJUNTO COM O MÓDULO DE VENTILAÇÃO (EVAPORADOR 40MZB) MONTAGEM HORIZONTAL MONTAGEM VERTICAL OBS: A montagem deve ser especificada no momento da compra. 7 2.5. MÓDULO CAIXA DE MISTURA (OPCIONAL) DIMENSIONAL DOS FILTROS INCORPORADOS A CAIXA DE MISTURA A caixa de mistura para as unidades 40MZB é montada sempre antes do módulo trocador de calor. O Módulo Caixa de Mistura é fabricado com parede dupla em chapa de aço galvanizado e isolamento interno de poliestireno expandido com espessura de 1/2”. Possui dampers fabricados em chapa de aço galvanizado, com lâminas opostas e eixo para acionamento manual ou automático. Modelo Quando montada, esta caixa de mistura incorpora uma variedade de opções de filtros. – G0 tela metálica 1” – G2 fibra de vidro 1” – G3 fibra de vidro 1” – G0 tela metálica 1” + G2 fibra de vidro de 1” – G0 tela metálica 1” + G3 fibra de vidro de 1” – G2 fibra de vidro 2” – G3 fibra de vidro 2” Os filtros G2 e G3 fibra de vidro ainda possuem as seguintes opções: ‘descartável’ ou ‘com moldura metálica’. 8 Dimensões dos Filtros (mm) Quant. ITC18 - 40MZB 240 ITC20 - 40MZB 300 372 x 416 469 x 478 10 8 ITC25 - 40MZB 390 ITC30 - 40MZB 480 469 x 466 499 x 434 10 12 ITC35 - 40MZB 540 ITC40 - 40MZB 630 499 x 493 555 x 436 12 14 3. CARACTERÍSTICAS TÉCNICAS GERAIS Unidade Evaporadora 40 MZB Características 240 300 390 480 540 630 Capacidade (kcal/h) [1] com 38MZ 56810 70062 92480 110587 126707 148774 Capacidade (kcal/h) [1] com 38AB 57730 73370 94665 111400 130677 151500 Alimentação Principal (V / F / Hz) 220 , 380 , 440 / 3 / 60 Tensão de Comando (V / F / Hz) 24 / 1 / 60 N. circuitos frigoríficos 1 2 3 N. estágios de capacidade 1 2 3 Refrigerante - Tipo R-22 Área face (m2) 1,4 1,65 2,05 2,34 2,74 3,13 N. filas 4 S e Diâmetro tubos 1/2” r Aletas polegada 14 p e Tipo Aletas Alumínio Corrugado e Tubos Cobre n N. circuitos 1 2 3 t Linha Líquido i 1 x 5/8” - solda 2 x 5/8” - solda 3 x 5/8” - solda n Quant./Diâmetro/Tipo a Linha Sucção 1 x 1 3/8” - solda 2 x 1 3/8” - solda 3 x 1 3/8” - solda Quant./Diâmetro/Tipo Tipo Centrífugo Duplo Centrífugo Triplo V e Vazão ( m3/h ) 10880 - 16320 13600 - 20400 17680 - 26520 21760 - 32640 24480 - 36720 28560 - 42840 n VS 720 - 950 770 - 950 620 - 780 720 -900 800 800 t Rotação (rpm) i VA ND ND ND 920 860 860 l VH 970 - 1220 1010 - 1200 790 - 990 950 925 925 a VS 9 - 25 7 - 24 10 - 24 19 - 37 18 19 d o P.E.D. (mmCA) VA ND ND ND 39 26 26 r VH 26 - 37 29 - 47 25 - 45 43 35 34 Quantidade - N. Pólos 1-4 M o VS 6 - 112M 7.5 - 112M 7.5 - 112M 12.5 - 132M 15 - 132M 20 - 160M t Potência (CV) - carcaça VA ND ND ND 15 - 132M 20 - 160M 20 - 160M o r VH 10 - 132S 10 - 132S 12.5 - 132M 15 - 132M 20 - 160M 20 - 160M Correia V - Tipo/Quant. B44 / 1 B57 / 1 B60 / 2 B55 / 2 B56 / 2 B65 / 2 Polia Motor (mm) 106 ~ 140 106 ~ 140 121.9 ~ 152.4 121.9 ~ 152.4 152,4 152,4 VS A c Polia Ventilador ( mm) 253,8 253,8 345 296,4 334 334 i o Correia V - Tipo/Quant ND ND ND B56 / 3 B58 / 2 B68 / 2 n a VA Polia Motor (mm) ND ND ND 156,6 169 169 m e Polia Ventilador ( mm) ND ND ND 296,8 345,4 345,4 n t Correia V - Tipo/Quant. B42 / 2 B55 / 2 B58 / 2 B57 / 3 B56 / 2 B365 / 3 o VH 121.9 ~ 152.5 121.9 ~ 152.5 121.9 ~ 152.5 Polia Motor (mm) 161,5 169 165 Polia Ventilador ( mm) 220 220 271 296,8 320 296,8 18 / 10 / 9 23 / 12.5 / 11.5 23 / 12.5 / 11.5 32 / 20 / 18.4 43.7 / 25 / 21.8 S Regulagem Relé Sobrecarga VS e VA ND ND ND 57 / 32 / 28 g 43.7 / 25 / 21.8 57 / 32 / 28 220 / 380 / 440 Volts VH 31 / 17 / 16 31 / 17 / 16 32 / 20 / 18.4 Peso Evaporadora (T + V) 384 548 656 778 961 1134 [1] Condições ARI 210 TBS=26,7°C e TBU=19,4°C para o ar entrando na unidade evaporadora e 35°C para o ar entrando na unidade condensadora. ND: Não disponível D: Disponível 9 UNIDADE CONDENSADORA CARACTERÍSTICAS Alimentação Principal (V - F - Hz) Tensão de Comando (V - F - Hz) Nº de circuitos frigoríficos Nº de estágios de capacidade Refrigerante - Tipo C Tipo O M Quantidade P R U E Rotação (rpm) N S Carga óleo (l) S I O D R Óleo recomendado A Área de face (m2) S D E Nº de filas E R P Diâmetro tubos E C N Aletas polegadas O T I N N Tipo D A Nº de circuitos E Linha líquido N C O S N Diâmetro/Conexão A E X D A Linha Sucção O O Diâmetro/Conexão R V Tipo A EN T Rotação (rpm) I L 3 Vazão (m3/h) A D 8 O M R P.E.D. (mmca) Z M Quantidade - nº pólos O T O Potência (CV) - carcaça R ALTA D I S P. D E S E G. BAIXA Desarme (psig) Rearme (psig) Desarme (psig) Rearme (psig) Fusível de Comando (A) Compressor Lock-out (CLO) Line Break Interno Termostato Interno Relé de Sobrecarga (A) - Compr. 220/380/440 Relé de Sobrecarga (A) - Vent. 220/380/440 Peso 38 MZ 150 240 220, 380, 440V / 3 / 60 24V / 1 / 60 1 1 R-22 Scroll 1 3480 2.69 5.49 Mineral - 160P 1.37 1.77 3 4 3/8" 17 Aletas de alumínio corrugado com Pre-coated (Gold Fin) e Tubos de cobre ranhurados internamente 1 5/8" -solda 1 3/8 "- solda Centrífugo Duplo 815 10200 720 15300 8 1-4 2 - 90S 3 - 90L 426 320 27 67 4 Garante o compressor contra ciclagem automática Garante o compressor contra sobrecarga e superaquecimento Garante o compressor contra sobrecarga e superaquecimento 70 / 40 / 37,5 8 / 4,4 / 3,2 9,8 / 5,7 / 4 350 412 10 UNIDADE CONDENSADORA CARACTERÍSTICAS Alimentação Principal (V - F - Hz) Tensão de Comando (V - F - Hz) Nº de circuitos frigoríficos Nº de estágios de capacidade Refrigerante - Tipo C Tipo O M Quantidade P U R Rotação (RPM) E N S Carga de óleo por compressor (l) S I O D R Óleo recomendado A Área de face (m 2) S D E Nº de filas E R P Diâmetro dos tubos E C N Aletas por polegadas O T I N Tipo N D A Nº de circuitos E N C Linha de líquido S O N QTD - Diâmetro - Tipo A E Linha de sucção D X Ã O O QTD - Diâmetro - Tipo R Tipo - Quantidade A V E Rotação (RPM) N T. 3 Vazão (m3/h) 8 M A O Quantidade - nº de pólos B TO Potência (CV) - carcaça R Desarme (psig) ALTA Rearme (psig) D Desarme (psig) BAIXA I Rearme (psig) S P. Fusível de Comando (A) Compressor Lock-out (CLO) S Line Break Interno Compr. Circ. 150 E G Termostato Interno Compr. Circ. 240 U R Relé de Sobrecarga Compr. Circ. 150 A (220/380/440V) Compr. Circ. 240 N Ç Relé de Sobrecarga (220/380/440V) Vent. A Peso (Kg) 150 240 CONDENSADORA 38AB 300 220, 380 OU 440 / 3 / 60 24 / 1 / 60 1 1 390 480 2 2 R-22 Scroll 1 2 2,69 3480 2 X 2,69 Mineral - 160P 2.064 3 3/8" 5,49 2 2,69 / 5,49 2 X 5,49 4 17 15 Aletas de alumínio corrugados com Pre-coated (Gold Fin) e Tubos de cobre ranhurados internamente 1 2 1 - 5/8" -BOLSA 2 - 5/8" -BOLSA 1 - 1 1/8"- BOLSA 2 - 1 1/8"- BOLSA Axial - 2 1140 38300 1130 43000 2-6 1 - 90S D ND 8.6 / 5.0 / 2.8 335 426 320 27 67 4 Garante o compressor contra ciclagem automática D D D ND D 70 / 40 / 37.5 70 / 40 / 37.5 8.6 / 5.0 / 2.8 8.6 / 5.0 / 2.8 8.6 / 5.0 / 2.8 350 390 460 [1] Condições ARI 210 TBS=26,7ºC e TBU=19,4ºC para o ar entrando na unidade evaporadora e 35ºC para o ar entrando na unidade condensadora. 11 1,5 - 90S ND D 70 / 40 / 37.5 10.5 / 6.2 / 4.0 490 440V 220V 380V 440 440 12 NOTA: 1 1 1 1 1 1 2 2 2 2 2 2 1 1 1 1 2 2 2 2 Qtde. Condensadora 38MZA150 32 32 32 32 32 32 32 32 32 32 16,2 16,2 16,2 16,2 16,2 16,2 16,2 16,2 16,2 16,2 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 50 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 25 25 28,9 28,9 28,9 28,9 28,9 28,9 28,9 28,9 28,9 28,9 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 12200 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Pot. Nom. Pot . Max. 220V 380V 220V 380V CV [W] [W] I Nom. [A] 440V I Max. [A] 440V Compressor 6,9 6,9 6,9 6,9 6,9 6,9 6,9 6,9 6,9 6,9 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 4 4 4 4 4 4 4 4 4 4 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 2051 FLA [A] FLA [A] 220V 380V Pot. [W] FLA [A] 440V Motor 2 2 2 2 2 2 1 1 1 1 1 1 2 2 2 2 2 2 1 1 1 1 1 1 1 1 Condensadora 38MZA240 47,6 47,6 47,6 47,6 47,6 47,6 47,6 47,6 47,6 47,6 47,6 47,6 47,6 23,8 23,8 23,8 23,8 23,8 23,8 23,8 23,8 23,8 23,8 23,8 23,8 23,8 27,4 27,4 27,4 27,4 27,4 27,4 27,4 27,4 27,4 27,4 27,4 27,4 27,4 75 75 75 75 75 75 75 75 75 75 75 75 75 37,5 37,5 37,5 37,5 37,5 37,5 37,5 37,5 37,5 37,5 37,5 37,5 37,5 43,2 43,2 43,2 43,2 43,2 43,2 43,2 43,2 43,2 43,2 43,2 43,2 43,2 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 18230 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Pot. Nom. Pot . Max. 220V 380V 220V 380V CV [W] [W] I Nom. [A] 440V I Max. [A] 440V Compressor . Os motores dos ventiladores são trifásicos; . A variação da voltagem deve ser no máximo ±10%; . A bitola do alimentador será dimensionada da seguinte forma: - Multiplicar por 1,25 a corrente máxima (Cor. Máx.) do maior compressor do conjunto; - Somar a corrente máxima dos demais compressores e motores dos ventiladores do evaporador e condensadores do conjunto; - Os cabos deverão ser classe 105OC ou superior; . Dados nominais obtidos na avaliação ARI 210. 40MZB630446VH 40MZB630236VH 220 380 440 40MZB630236VA 220 380 440 40MZB630446VA 40MZB630236VS 220 380 440 40MZB630446VS 40MZB540446VH 40MZB540236VH 220 380 440 40MZB540446VA 40MZB540236VA 220 380 440 40MZB540236VS 220 380 440 40MZB540446VS 40MZB480446VH 40MZB480236VH 220 380 440 40MZB480236VA 220 380 440 40MZB480446VA 40MZB480446VS 40MZB480236VS 220 380 440 40MZB390446VH 40MZB390236VH 220 380 440 40MZB390236VS 220 380 440 40MZB390446VS 40MZB300446VH 40MZB300236VH 220 380 440 40MZB300236VS 220 380 440 40MZB300446VS 40MZB240446VH 40MZB240236VH 220 380 40MZB240446VS 40MZB240236VS 220 380 Modelo Tensão Qtde. 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 8,6 4,3 4,3 4,3 4,3 4,3 4,3 4,3 4,3 4,3 4,3 4,3 4,3 4,3 5 5 5 5 5 5 5 5 5 5 5 5 5 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2276 2776 2776 2776 2776 2776 2776 2776 2776 FLA [A] FLA [A] 220V 380V Pot. [W] FLA [A] 440V Motor 20 20 20 20 20 20 20 20 20 20 15 15 15 15 15 15 12,5 12,5 12,5 12,5 7,5 7,5 10 10 7,5 7,5 10 10 6 6 CV 50 50 50 50 50 38 38 38 32 32 19,9 26,3 19,9 26,3 16 25 25 25 25 25 19 19 19 16 16 9,95 13,1 9,95 13,1 8 28,9 28,9 28,9 28,9 28,9 22 22 22 18,5 18,5 11,5 15,2 11,5 15,2 9,2 FLA [A] 440V 17041 17041 17041 17041 17041 17041 17041 17041 17041 17041 12453 12453 12453 12453 12453 12453 10487 10487 10487 10487 6249 6249 8642 8642 6249 6249 8642 8642 5246 5246 41,6 47,6 56,5 66,4 86,8 63,4 92,6 99,6 136 117,8 235,4 102,6 205,2 118,4 102,6 205,2 118,4 99,6 199,2 114,9 86,3 172,5 80,25 160,4 70,1 140,1 81 77,3 66,95 133,7 54,9 109,9 49,8 57,4 440V 99,6 123,8 123,8 137,1 137,1 100,9 137,1 201,3 116,2 274,1 158,2 100,9 201,3 116,2 274,1 158,2 100,9 201,3 116,2 274,1 158,2 92,5 106,3 247,4 142,9 92,5 106,3 247,4 142,9 86,5 99,4 75,2 150,4 184 86,8 75,2 150,4 184 83,3 72,2 144,4 172 73,4 63,8 127,1 57,75 115 60,2 52,5 104,1 49,35 97,7 41,2 82,5 36,1 72,2 440V I Nom. Total [A] 66924 66924 66924 66924 66924 66924 61259 61259 61259 61259 56671 56671 49485 49485 49485 49485 47519 47519 42354 42354 38116 38116 34344 34344 31951 31951 27658 27658 24262 24262 72304 72304 72304 72304 72304 72304 66049 66049 66049 66049 61461 61461 53465 53465 53465 53465 51499 51499 45744 45744 41506 41506 37144 37144 34751 34751 29648 29648 26252 26252 315 315 315 315 315 315 250 250 250 200 200 160 160 160 125 160 160 160 160 160 160 125 125 125 100 100 80 80 80 63 80 80 200 200 200 200 200 200 160 160 160 125 125 100 100 440V I Máx. Total Fusível Total [A] Potência Potência Recomendado Nominal Máxima FLA [A] FLA [A] 220V 380V 220V 380V Total [W] Total [W] 220V 380V 220V 380V Pot. [W] Modulo Ventilação 4 - DADOS ELÉTRICOS 13 440 440 440 440 380 380 380 380 220 220 220 440 440 440 440V 1 1 1 1 380 380 380 380V Tensão 440 440 440 440 440V 220V 220 220 220 220 220V 380 380 380 380 Condensadora 38ABA240 1 1 1 1 32 32 16,2 16,2 50 50 25 25 [W] 28,9 28,9 I Max. [A] 440V Compressor 1 18,5 18,5 I Nom. [A] 440V [W] 10800 10800 10800 10800 [W] 2 2 2 2 1 1 1 1 3,77 1,89 1,89 [W] 2,18 2,18 FLA [A] 440V 3,77 Condensadora 38ABA300 12200 12200 12200 12200 [W] [W] 962 962 962 962 1 1 1 1 23,8 23,8 27,4 27,4 Motor (cada) 47,6 47,6 I Nom. [A] 440V 75 75 37,5 37,5 43,2 43,2 I Max. [A] 440V Compressor Motor (cada) Modulo Ventilação I Nom. Total [A] I Máx. Total [A] Fusível Total 16240 16240 16240 16240 [W] 2 2 2 2 1 1 1 1 Compressor 1 18230 18230 18230 18230 [W] [W] 3,77 3,77 2,18 2,18 [W] 1,89 1,89 FLA [A] 440V 962 6 10 10 6 26,3 16 13,6 13,1 8 6,8 5,8 15,2 9,2 7,9 6,7 FLA [A] 440V 11,6 Condensadora 38ABA390 962 962 962 5 5 4 4 [W] 8642 8642 5243 5243 4301 4301 3625 3625 30,8 41,0 [W] 41,2 56,8 49,3 98,5 35,6 71,1 34,6 40,0 440V 69,1 26806 26806 23407 23407 17025 17025 16349 16349 Motor (cada) 54,4 47,0 108,8 62,8 40,7 81,4 35,6 71,1 26,8 53,1 25,8 29,6 440V 51,1 28796 28796 25397 25397 18425 18425 17749 17749 80 63 80 80 63 63 Modulo Ventilação 160 125 63 63 440V 100 80 16,2 16,2 18,5 18,5 50 50 28,9 10800 10800 10800 10800 Compressor 1 25 25 28,9 I Max. [A] 440V [W] 12200 12200 12200 12200 32 32 [W] 16,2 16,2 50 50 25 25 28,9 28,9 I Max. [A] 440V 10800 10800 10800 10800 Condensadora 38ABA480 18,5 18,5 I Nom. [A] 440V 12200 12200 12200 12200 2 2 2 2 [W] 1 1 1 1 [W] 3,77 1,89 1,89 2,18 2,18 FLA [A] 440V 3,77 962 962 962 962 47,6 47,6 Motor (cada) 1 1 1 1 23,8 23,8 27,4 27,4 I Nom. [A] 440V 75 75 43,2 43,2 16240 16240 16240 16240 18230 18230 18230 18230 Modulo Ventilação 37,5 37,5 I Max. [A] 440V 16,2 16,2 18,5 18,5 50 50 25 25 28,9 28,9 I Max. [A] 440V I Nom. Total [A] I Máx. Total [A] 32 32 I Nom. [A] 440V Compressor 2 10800 10800 10800 10800 12200 12200 12200 12200 2 1 1 1 1 Fusível Total 2 2 2 1 1 1 1 1 1 47,6 47,6 47,6 23,8 23,8 23,8 27,4 27,4 27,4 I Nom. [A] 440V 75 75 75 37,5 37,5 37,5 43,2 43,2 43,2 I Max. [A] 440V 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 47,6 47,6 47,6 23,8 23,8 23,8 27,4 27,4 27,4 I Nom. [A] 440V 75 75 75 37,5 37,5 37,5 43,2 43,2 43,2 I Max. [A] 440V Compressor 2 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 2 2 2 2 2 2 2 2 2 2 2 2 6,9 6,9 6,9 3,5 3,5 3,5 4 4 4 FLA [A] 440V 2051 2051 2051 2051 15 15 15 15 2051 12,5 2051 12,5 38 38 32 19 19 16 22 22 18,5 FLA [A] 440V 440V 70,6 98,0 73,6 101,0 12453 73,6 101,0 12453 147,0 84,8 201,8 116,4 12453 12453 147,0 84,8 201,8 116,4 10487 10487 141,0 81,3 195,8 112,9 440V 49035 49035 49035 49035 47069 47069 53015 53015 53015 53015 51049 51049 225 225 225 125 125 125 160 160 160 440V Potência Potência Recomendado Nominal Máxima I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] FLA [A] FLA [A] FLA [A] FLA [A] Qtde. 220V 380V 220V 380V Total [W] Total [W] 220V 380V 220V 380V 220V 380V Pot. Nom. Pot . Max. 220V 380V 220V 380V Pot. Nom. Pot . Max. Qtde. CV 220V 380V Pot. [W] CV 220V 380V Pot. [W] 32 32 I Nom. [A] 440V Compressor 2 I Nom. Total [A] I Máx. Total [A] Fusível Total 3,77 3,77 1,89 1,89 2,18 2,18 FLA [A] 440V 962 962 962 962 12,5 12,5 7,5 7,5 10 10 7,5 7,5 32 19,9 26,3 19,9 16 9,95 13,1 9,95 18,5 11,5 15,2 11,5 FLA [A] 440V 63,7 49,3 66,9 56,6 133,8 77,4 46,1 97,8 440V 52,9 127,4 73,7 440V 91,4 53,7 76,2 10487 59,8 82,3 10487 119,1 68,8 164,5 95,0 6249 6249 107,0 61,8 152,4 88,0 8642 8642 6249 6249 39451 39451 35213 35213 32166 32166 29773 29773 42841 42841 38603 38603 34966 34966 32573 32573 200 200 160 160 100 100 80 80 125 100 100 100 440V Potência Potência Recomendado Nominal Máxima I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] FLA [A] FLA [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] FLA [A] FLA [A] FLA [A] FLA [A] Qtde. 380V Qtde. 220V 380V 220V 380V Total [W] Total [W] 220V 380V Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V Qtde. CV 220V 380V Pot. [W] Qtde. CV 220V 380V Pot. [W] CV 220V 380V Pot. [W] Tensão 220 220 220 220 380V 440V 220V Motor (cada) Potência Potência Recomendado Nominal Máxima I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] FLA [A] FLA [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] FLA [A] FLA [A] FLA [A] FLA [A] Qtde. Qtde. 220V 380V 220V 380V Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. Total [W] Total [W] 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V Qtde. CV 220V 380V Pot. [W] Qtde. CV 220V 380V Pot. [W] CV 220V 380V Pot. [W] Condensadora 38ABA150 Compressor NOTA: . Os motores dos ventiladores são trifásicos; . A variação da voltagem deve ser no máximo ±10%; . A bitola do alimentador da unidade será dimensionada da seguinte forma: - Multiplicar por 1,25 a corrrente máxima (Cor. Máx.) do maior compressor do conjunto; - Somar a corrente máxima dos demais compressores e motores dos ventiladores do evaporador e condensadores do conjunto; - Os cabos deverão ser classe 105 OC ou superior; . Dados nominais obtidos na avaliação ARI 210. . As unidades condensadoras 38AB líder sempre serão as com maior capacidade de refrigeração; . Em uma unidade 38AB com 2 (dois) compressores, o circuito 1 sempre será o de maior capacidade de refrigeração. 40MZB480446VH 40MZB480236VH 40MZB480446VSA 40MZB480236VSA 40MZB480446VS 40MZB480236VS Modelo 40MZB390446VH 40MZB390236VH 40MZB390446VS 40MZB390236VS 40MZB300446VH 40MZB300236VH 40MZB300446VS 40MZB300236VS Modelo 40MZB240446VH 40MZB240236VH 40MZB240446VS 40MZB240236VS 40MZB150446VH 40MZB150236VH 40MZB150446VS 40MZB150236VS Modelo Tensão 14 440 440 440 380 380 380 440 440 440 380 380 380 440 440 440 380 380 380 1 1 1 1 1 1 Qtde. 1 1 1 1 1 1 Qtde. 1 1 1 1 1 1 Qtde. 16,2 16,2 16,2 18,5 18,5 18,5 28,9 28,9 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 Condensadora 38ABA240 25 25 25 28,9 Compressor 50 50 50 2 2 2 2 2 2 1 1 1 1 1 1 CV 23,8 23,8 23,8 27,4 27,4 27,4 43,2 43,2 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 Condensadora 38ABA150 37,5 37,5 37,5 43,2 Compressor 75 75 75 2 2 2 2 2 2 32 32 32 16,2 16,2 16,2 18,5 18,5 18,5 28,9 28,9 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 Condensadora 38ABA240 25 25 25 28,9 Compressor 50 50 50 2 2 2 2 2 2 I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Pot. Nom. Pot . Max. 220V 380V 220V 380V Qtde. [W] [W] I Nom. [A] 440V I Max. [A] 440V 47,6 47,6 47,6 1 1 1 1 1 1 CV 1 1 1 1 1 1 I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Pot. Nom. Pot . Max. 220V 380V 220V 380V Qtde. CV [W] [W] I Nom. [A] 440V I Max. [A] 440V 32 32 32 I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Pot. Nom. Pot . Max. 220V 380V 220V 380V Qtde. [W] [W] I Nom. [A] 440V I Max. [A] 440V 220 220 220 440 440 440 380 380 380 1 1 1 1 1 1 47,6 47,6 47,6 23,8 23,8 23,8 27,4 27,4 27,4 75 75 75 37,5 37,5 37,5 43,2 43,2 43,2 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 2 2 2 2 2 2 1 1 1 1 1 1 I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] 220V 380V Qtde. Pot. Nom. Pot . Max. 220V 380V 220V 380V Qtde. CV [W] [W] 440V I Nom. [A] 440V I Max. [A] 440V Tensão 220 220 220 380V 440V 220V Tensão 220 220 220 380V 440V 220V Tensão 220 220 220 380V 440V 220V Condensadora 38ABA150 Compressor Compressor 1 Compressor 2 Condensadora 38ABA390 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 1 1 1 1 1 1 47,6 47,6 47,6 23,8 23,8 23,8 27,4 27,4 27,4 37,5 37,5 37,5 43,2 43,2 43,2 Compressor 1 75 75 75 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 16,2 16,2 16,2 18,5 18,5 18,5 50 50 50 25 25 25 28,9 28,9 28,9 Compressor 2 Condensadora 38ABA300 32 32 32 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 2 2 2 2 2 2 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 1 1 1 1 1 1 32 32 32 16,2 16,2 16,2 18,5 18,5 18,5 25 25 25 28,9 28,9 28,9 Compressor 1 50 50 50 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 16,2 16,2 16,2 18,5 18,5 18,5 50 50 50 25 25 25 28,9 28,9 28,9 Compressor 2 Condensadora 38ABA480 32 32 32 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 2 2 2 2 2 2 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 1 1 1 1 1 1 47,6 47,6 47,6 23,8 23,8 23,8 27,4 27,4 27,4 37,5 37,5 37,5 43,2 43,2 43,2 Compressor 1 75 75 75 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 23,8 23,8 23,8 27,4 27,4 27,4 75 75 75 37,5 37,5 37,5 43,2 43,2 43,2 Compressor 2 Condensadora 38ABA390 47,6 47,6 47,6 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 2 2 2 2 2 2 3,77 3,77 3,77 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 1 1 1 1 1 1 47,6 47,6 47,6 23,8 23,8 23,8 27,4 27,4 27,4 75 75 75 37,5 37,5 37,5 43,2 43,2 43,2 16240 16240 16240 16240 16240 16240 18230 18230 18230 18230 18230 18230 32 32 32 16,2 16,2 16,2 18,5 18,5 18,5 50 50 50 25 25 25 28,9 28,9 28,9 10800 10800 10800 10800 10800 10800 12200 12200 12200 12200 12200 12200 2 2 2 2 2 2 FLA [A] FLA [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Qtde. Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. 220V 380V Pot. [W] 220V 380V 220V 380V 220V 380V 220V 380V Qtde. [W] [W] [W] [W] I Nom. [A] 440V I Max. [A] 440V I Nom. [A] 440V I Max. [A] 440V FLA [A] 440V Motor (cada) 3,77 3,77 3,77 FLA [A] FLA [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Qtde. Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. 220V 380V Pot. [W] 220V 380V 220V 380V 220V 380V 220V 380V Qtde. [W] [W] [W] [W] FLA [A] 440V I Nom. [A] 440V I Max. [A] 440V I Nom. [A] 440V I Max. [A] 440V Motor (cada) 3,77 3,77 3,77 FLA [A] FLA [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Qtde. Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. 220V 380V Pot. [W] 220V 380V 220V 380V 220V 380V 220V 380V Qtde. [W] [W] [W] [W] I Nom. [A] 440V I Max. [A] 440V I Nom. [A] 440V I Max. [A] 440V FLA [A] 440V Motor (cada) 3,77 3,77 3,77 FLA [A] FLA [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] I Nom. [A] I Nom. [A] I Max. [A] I Max. [A] Qtde. Pot. Nom. Pot . Max. Pot. Nom. Pot . Max. 220V 380V Pot. [W] 220V 380V 220V 380V 220V 380V 220V 380V Qtde. [W] [W] [W] [W] FLA [A] 440V I Nom. [A] 440V I Max. [A] 440V I Nom. [A] 440V I Max. [A] 440V Motor (cada) NOTA: . Os motores dos ventiladores são trifásicos; . A variação da voltagem deve ser no máximo ±10%; . A bitola do alimentador da unidade será dimensionada da seguinte forma: - Multiplicar por 1,25 a corrrente máxima (Cor. Máx.) do maior compressor do conjunto; - Somar a corrente máxima dos demais compressores e motores dos ventiladores do evaporador e condensadores do conjunto; - Os cabos deverão ser classe 105 OC ou superior; . Dados nominais obtidos na avaliação ARI 210. . As unidades condensadoras 38AB líder sempre serão as com maior capacidade de refrigeração; . Em uma unidade 38AB com 2 (dois) compressores, o circuito 1 sempre será o de maior capacidade de refrigeração. 40MZB630446VH 40MZB630236VH 40MZB630446VSA 40MZB630236VSA 40MZB630446VS 40MZB630236VS Modelo 40MZB630446VH 40MZB630236VH 40MZB630446VSA 40MZB630236VSA 40MZB630446VS 40MZB630236VS Modelo 40MZB540446VH 40MZB540236VH 40MZB540446VSA 40MZB540236VSA 40MZB540446VS 40MZB540236VS Modelo 40MZB540446VH 40MZB540236VH 40MZB540446VSA 40MZB540236VSA 40MZB540446VS 40MZB540236VS Modelo Tensão 1 1 1 1 1 1 CV 2 2 2 2 2 2 CV 1 1 1 1 1 1 CV 1 1 1 1 1 1 CV 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 3,5 3,5 3,5 4 4 4 2051 2051 2051 2051 2051 2051 3,77 3,77 3,77 1,89 1,89 1,89 2,18 2,18 2,18 962 962 962 962 962 962 FLA [A] FLA [A] 220V 380V Pot. [W] FLA [A] 440V Motor (cada) 6,9 6,9 6,9 FLA [A] FLA [A] 220V 380V Pot. [W] FLA [A] 440V Motor (cada) 3,77 3,77 3,77 FLA [A] FLA [A] 220V 380V Pot. [W] FLA [A] 440V Motor (cada) 3,77 3,77 3,77 FLA [A] FLA [A] 220V 380V Pot. [W] FLA [A] 440V Motor (cada) 20 20 20 20 20 20 CV 20 20 20 20 20 20 CV 20 20 20 20 15 15 CV 20 20 20 20 15 15 CV 25 25 19 28,9 28,9 22 82,8 88,8 25 25 28,9 28,9 17041 25 25 28,9 28,9 82,8 50 50 25 25 25 28,9 28,9 28,9 114,1 88,8 120,1 17041 120,1 99,6 135,8 99,6 135,8 17041 135,8 96,4 132,6 96,4 132,6 17041 96,4 132,6 17041 192,3 110,9 265,1 152,9 17041 17041 192,3 110,9 265,1 152,9 17041 17041 192,3 110,9 265,1 152,9 440V 220V 58729 58729 58729 58729 54141 54141 63519 63519 63519 63519 58931 58931 40 40 440V 50 50 50 Fusível Recomendado 80 80 80 Fusível Recomendado 125 125 125 40 100 100 440V 100 200 200 200 160 160 160 160 160 Fusível Total 250 250 160 440V 250 58729 58729 58729 58729 54141 54141 63519 63519 63519 63519 58931 58931 40 40 440V 50 50 50 Fusível Recomendado 80 80 80 Fusível Recomendado 125 125 125 40 100 100 440V 100 200 200 200 160 160 160 160 160 Fusível Total 250 250 160 440V 250 66347 66347 66347 66347 66347 66347 71727 71727 71727 71727 71727 71727 40 40 440V 50 50 50 Fusível Recomendado 80 80 80 Fusível Recomendado 160 160 160 40 125 125 440V 125 250 250 250 160 160 200 200 200 Fusível Total 315 315 160 440V 315 64169 64169 64169 64169 64169 64169 69549 69549 69549 69549 69549 69549 250 250 250 125 125 125 440V 160 160 160 80 80 80 40 40 40 440V 50 50 50 315 315 315 160 160 160 200 200 200 440V Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado Nominal Máxima 380V Total [W] Total [W] 220V 380V 220V 380V 220V 380V I Nom. Total [A] I Máx. Total [A] 99,6 17041 198,5 114,6 271,3 156,6 17041 17041 198,5 114,6 271,3 156,6 17041 17041 198,5 114,6 271,3 156,6 440V 220V Fusível Total Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado Nominal Máxima 380V Total [W] Total [W] 220V 380V 220V 380V 220V 380V I Nom. Total [A] I Máx. Total [A] 88,8 17041 176,7 102,0 240,1 138,6 17041 17041 176,7 102,0 240,1 138,6 12453 FLA [A] FLA [A] 220V 380V 220V 380V Pot. [W] FLA [A] 440V 440V 50 440V 220V Fusível Recomendado Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado Nominal Máxima 380V Total [W] Total [W] 220V 380V 220V 380V 220V 380V 12453 164,7 95,1 228,1 131,7 Modulo Ventilação 50 50 25 28,9 120,1 I Nom. Total [A] I Máx. Total [A] 88,8 FLA [A] FLA [A] 220V 380V 220V 380V Pot. [W] FLA [A] 440V 440V 50 120,1 17041 176,7 102,0 240,1 138,6 17041 Modulo Ventilação 50 50 19 22 114,1 17041 176,7 102,0 240,1 138,6 12453 FLA [A] FLA [A] 220V 380V 220V 380V Pot. [W] FLA [A] 440V 440V 38 440V 12453 164,7 95,1 228,1 131,7 Modulo Ventilação 50 50 38 220V Fusível Recomendado Potência Potência Cond. Líder + Evap Cond. Escrava Recomendado Nominal Máxima 380V Total [W] Total [W] 220V 380V 220V 380V 220V 380V I Nom. Total [A] I Máx. Total [A] FLA [A] FLA [A] 220V 380V 220V 380V Pot. [W] FLA [A] 440V 440V Modulo Ventilação 5 - DADOS DIMENSIONAIS C - MÓDULO DE VENTILAÇÃO 40MZB A - UNIDADE 38MZ Cotas Cotas A B C D E F G H I J 150 1510 1836 700 700 1136 92 996 341 46 241 240 1910 1836 700 700 1136 92 996 402 46 291 Cotas K L M N O P Q R S T 150 1027 1375 816 736 492 422 352 105 423 495 240 1327 1775 816 736 492 422 352 105 423 495 540 630 A 3050 3150 B 1000 1000 C 1130 1260 D 375 E 2300 2300 425 F 480 480 G 76 76 H 150 150 J 561 561 K 316 316 Fig. 2c Fig. 2a D - MÓDULO TROCADOR DE CALOR 40MZB B - MÓDULO DE VENTILAÇÃO 40MZB (240/300/390/480) Fig. 2d Cotas A B C D E F G H 240 2170 710 875 421 1327 402 473 75 300 2000 840 1070 336 1327 402 473 75 390 2420 840 1070 425 1569 480 556 75 480 2700 1000 1130 565 1569 480 556 75 **Para insuflamento em outra posição diferente da mostrada no desenho, os bocais dos ventiladores estarão posicionados na distância H da borda. D e E permanecem iguais. Fig. 2b 15 Cotas A B C D E F G H I K L M N O P Q R 240 2170 710 765 875 180 42 142 242 342 - 300 2000 840 895 1070 180 107 207 307 407 - 390 2420 840 895 1070 180 107 207 307 407 - 480 2700 1000 1055 1130 180 187 287 387 487 - 540 3050 1000 1055 1130 260 180 200 200 200 200 187 287 630 3150 1000 1055 1260 260 180 200 200 200 200 187 287 E - UNIDADE 38AB Cotas 150 / 240 / 300 / 390 / 480 A 2190 B 1062 C 1065 D 1141 E 594 F 1001 G 545 H 500 J 298 K 78 L 143 M 197 N 246 P 100 Fig. 2e - Dimensões da Unidade 38AB F - CAIXA DE MISTURA (OPCIONAL) Altura (mm) Largura (mm) Profund. (mm) Peso (kg) Modelo 160 ITC 18 - 40MZB 240 875 2170 820 207 ITC 20 - 40MZB 300 1070 2000 820 246 ITC 25 - 40MZB 390 1070 2420 820 337 ITC 30 - 40MZB 480 1130 2700 820 378 ITC 35 - 40MZB 540 1130 3050 820 432 ITC 40 - 40MZB 630 1260 3150 820 Damper Externo (mm) Damper Retorno (mm) Modelo ITC 18 - 40MZB 240 550 950 750 450 ITC 20 - 40MZB 300 750 850 750 500 ITC 25 - 40MZB 390 750 1050 750 750 ITC 30 - 40MZB 480 750 1200 750 750 ITC 35 - 40MZB 540 750 1400 750 850 ITC 40 - 40MZB 630 750 1600 750 950 Fig. 2f - Dimensões da Caixa de Mistura 16 NOTAS: 1. As conexões elétricas podem ser feitas por ambos os lados nas unidades 38MZ e no módulo de ventilação 40MZB. Na unidade 38AB as conexões elétricas são feitas pelo lado direito da unidade. Recomenda-se isolar o cabo de ligação do motor do evaporador com um conduite. 2. A conexão para drenagem pode ser feita por ambos os lados do módulo trocador de calor 40MZB. Nas unidades condensadoras não existem conexões para dreno, a drenagem é feita pela parte inferior do gabinete. 3. Prever suficiente espaço para serviços de manutenção conforme figura 4. A frente do equipamento deve permanecer desimpedida para permitir o livre fluxo de ar e o acesso ao interior da unidade. 4. Em caso de montagem de, vários equipamentos na mesma área, respeitar as distâncias mínimas e arranjos indicados na figura 5. 500 B - 38MZ EM CIMA OU EMBAIXO PARA MANUTENÇÃO A - 40MZB 110 E ÕES ) NEX (CO ÉTRICA EL MAN 600 UTE NÇÃ O 500 RE 500 T E M ORN AN O D UT E EN A R ÇÃ O ES E EXÕ CON RICA T ELÉ C - 38AB Fig. 4 - Espaços mínimos requeridos para instalação 17 1 CUL 8 0 0 A (EX ÇÃO D TER E IOR AR ) CIR MÓDULOS 38MZ 38MZ 38MZ 38MZ (ESCOLHER UM DOS DOIS LADOS DA UNIDADE O OUTRO PODE FICAR ENCOSTADO NA PAREDE) 38MZ Figura 5 - Distâncias mínimas de montagem 18 6 - PROCEDIMENTOS DE SELEÇÃO 6.1 - DADOS DE PROJETO Capacidade Total (C.T.) Capacidade Sensível (C.S.) Vazão de ar no Evaporador (V) Condições de ar na entrada do evaporador (T.B.S.E./T.B.U.E.) Temperatura do ar de entrada no condensador (T.A.C.) 67000 kcal/h 50000 kcal/h 17000 m3/h 24/18OC 35OC 6.2 - FÓRMULAS Capacidade Sensível corrigida: C.S.C. = C.S. + [0.29 x V x (1 - B.F.) x (T.B.S.E. - 26.7) [ KCal/h)] onde B.F. = Fator de By-Pass Temperatura de bulbo seco na saída da serpentina T.B.S.S. = T.B.S.E. - [C.S./ (0,29 x V)] Diferencial de [C.S. / (0,29 x V)] Temperatura (DT) DT = T.S.C. - T.A.C. onde T.S.C. = Temperatura Saturada de Condensação 6.3 - PROCEDIMENTOS PARA SELEÇÃO 6.3.1 - CÁLCULO DAS CAPACIDADES Entrar na tabela 7, com a vazão de ar e T.B.U.E. Entrar na horizontal com a T.A.C. C.T. = 67815 Kcal/h C. S. = 67557 Kcal/h 40MZ 300 C.T.R. = 90555 Kcal/h Obs.: Se o T.B.S.E. for diferente de 26,7OC fazer a correção do C.S. Logo: 24 = 26,7 Portanto fazer a correção C.S.C. =C.S. + [0,29 x V x (1 - B.F.) x (T.B.S.E. - 26,7)] C.S. = 67557 Kcal/h V = 17000 m3/h B.F. = 0,07 (Tabela de selecionamento) C.S.C = 55178 Kcal/h Comparar C.S.C. com o dado de projeto, se for maior ou igual estará ok. 55178 >50000 6.4 - UNIDADE SELECIONADA 40MZB 300 C.T = 67815 Kcal/h C.S. = 67557 Kcal/h C.T.R = 90555 Kcal/h 19 7 - TABELAS DE SELECIONAMENTO 40MZB240/38MZA240 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 16320 - 0.10 16 18 20 22 16 18 20 22 16 18 20 22 56241 59514 62879 57420 58074 61070 64460 59785 59772 62185 65513 C.S. 54207 49906 42851 35503 57420 56094 47930 39088 59785 59772 52788 42555 C.T.R. 66321 68534 72086 75730 69806 70529 73769 77444 72370 72355 74979 78580 38,5 38,9 39,5 40,1 39,1 39,2 39,8 40,4 39,5 39,5 40,0 40,6 C.T. 53028 54728 57885 61253 56140 56496 59361 62684 58323 58312 60455 63714 C.S. 53028 49180 42160 34881 56140 55194 47237 38465 58323 58312 52070 41932 C.T.R. 66250 68117 71580 75277 69663 70057 73203 76836 72048 72037 74405 77963 43,8 44,2 44,8 45,4 44,4 44,5 45,1 45,7 44,8 44,8 45,3 45,9 C.T. 51747 53191 56179 59435 54660 54899 57631 60829 56823 56822 58662 61832 C.S. 51747 48481 41486 34219 54660 54235 46567 37833 56823 56821 51343 41267 C.T.R. 66133 67749 71049 74659 69359 69628 72663 76201 71751 71750 73812 77310 T.S.C. 40 13600 - 0.07 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 54207 T.S.C. 35 10880 - 0.06 C.T. T.S.C. 30 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 49,0 49,4 50,0 50,6 49,6 49,7 50,3 50,9 50,0 50,0 50,5 51,1 C.T. 50495 51627 54474 57580 53172 53238 55880 58900 55285 55276 56807 59869 C.S. 50495 47755 40788 33574 53172 53237 45853 37149 55285 55276 50529 40667 C.T.R. 66150 67437 70605 74071 69140 69212 72183 75547 71500 71491 73216 76634 T.S.C. 54,1 54,5 55,1 55,7 54,7 54,7 55,4 56,0 55,2 55,2 55,6 56,2 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 40MZB300/38MZA150/38MZA150 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 20400 - 0.10 20 22 16 18 20 22 16 18 20 C.T. 68023 71837 74148 78618 71639 72080 76930 80386 74516 74167 78769 C.S. 68014 62424 51595 43154 71639 67502 57597 47088 74516 73564 62366 C.T.R. 87272 89785 93650 97850 91340 91661 95725 100256 94618 93504 97185 40,1 40,7 41,3 41,9 40,7 40,1 41,5 42,2 41,3 41,1 41,6 C.T. 65060 68190 71899 75863 68893 70702 74002 78370 71728 71578 75441 C.S. 63337 60469 50999 41371 68893 69343 56681 46415 69546 71578 63273 C.T.R. 85521 88952 92914 96929 90035 91335 95325 99812 93087 93091 97114 44,9 45,9 46,5 46,8 45,9 46,2 46,5 47,3 46,1 46,4 46,8 C.T. 63490 65564 69485 74885 66768 67815 71024 77065 69358 69331 72755 C.S. 63487 58366 49857 42651 66768 67557 55622 47097 69358 69331 62367 C.T.R. 85773 87924 92058 97683 89477 90555 93824 100128 92405 92401 95944 T.S.C. 40 17000 - 0.07 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 18 T.S.C. 35 13600 - 0.06 16 T.S.C. 30 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 50,3 50,8 51,4 52,1 50,9 51,0 51,6 52,4 51,4 51,4 51,8 C.T. 61812 62943 66664 71452 66268 64728 69100 72151 66848 66892 69116 C.S. 61801 57263 48449 39762 66268 63798 55420 44130 66847 66892 59947 C.T.R. 85569 86941 90821 95714 90239 89088 93576 96707 91554 91613 93882 T.S.C. 55,2 55,6 56,3 56,8 51,9 56,0 56,5 57,3 56,3 56,4 56,8 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 20 40MZB390/38MZA150/38MZA240 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) C.T. 25 26520 - 0.11 16 18 88579 91966 20 97024 22 16 18 20 22 16 18 102149 93470 94540 99529 104788 97140 97101 88579 80868 69233 57423 93470 90690 77403 63127 97140 97100 108539 112236 117740 123299 113849 115023 120460 126171 117854 117812 39,2 39,7 40,3 40,9 39,8 40,0 40,6 41,2 40,3 40,3 86629 89410 94421 99483 91252 91989 96731 101951 94809 94793 C.S. 86629 79755 68280 56483 91251 89136 76258 62155 94808 94792 C.T.R. 108589 111635 117141 122682 113637 114456 119677 125403 117548 117525 T.S.C. C.T. 44,5 45,0 45,6 46,2 45,1 45,2 45,9 46,5 45,6 45,5 84373 86602 91535 96577 88964 89431 93786 98813 92209 92191 C.S. 84373 78345 67064 55374 88964 87775 75100 61036 92209 92191 C.T.R. 108398 110879 116330 121907 113475 114006 118818 124390 117052 117032 T.S.C. C.T. 40 22100 - 0.07 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) C.T.R. C.T. 35 17680 - 0.05 C.S. T.S.C. 30 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 49,7 50,1 50,7 51,3 50,3 50,4 51,0 51,6 50,7 50,7 82027 84004 88648 93452 86369 86680 90657 95476 89474 90258 C.S. 82027 77134 66237 54232 86369 85743 73874 59844 89474 87116 C.T.R. 108241 110464 115633 120996 113091 113433 117875 123256 116529 117413 T.S.C. 54,8 55,1 55,7 56,4 55,4 55,4 56,0 56,7 55,8 55,9 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 40MZB480/38MZA240/38MZA240 TEMPERATURADE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 35 40 27200 - 0.06 32640 - 0.13 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 18 20 22 16 C.T. 105932 109627 115763 122233 C.S. 105931 97834 83643 69239 C.T.R. 129970 133988 140680 147681 T.S.C. 30 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 21760 - 0.05 18 20 22 16 111710 112793 118918 125242 116264 116355 111710 109629 93843 76151 116264 116323 136278 137423 144081 150944 141192 141301 18 38,3 38,7 39,3 39,8 38,8 39,0 39,6 40,1 39,3 39,3 C.T. 103939 106421 113294 118983 109095 109777 115556 122135 113961 113492 C.S. 103939 96290 83179 68425 109095 107390 92421 75295 113961 113492 C.T.R. 130371 132923 140648 146688 135841 136586 142919 150143 142028 140678 T.S.C. 43,7 44,0 44,7 45,2 44,2 44,2 44,9 45,5 44,8 44,6 C.T. 101030 103397 109457 115654 106437 106936 112152 118455 110540 110493 C.S. 101030 94693 81070 66843 106436 105746 90984 73900 110540 110493 C.T.R. 129549 132184 138904 145761 135540 136095 141870 148862 140069 140017 T.S.C. 49,7 49,7 48,8 49,1 49,7 50,3 49,3 49,4 50,0 50,6 C.T. 98363 100509 106146 112186 103774 103881 108739 114707 107450 107480 C.S. 98363 93639 79821 65612 98363 93639 79821 65612 103774 103881 C.T.R. 129357 131784 138068 144829 135412 135561 140977 147645 139517 139534 T.S.C. 53,9 54,2 54,7 55,4 54,4 54,5 55,1 55,7 54,8 54,8 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 21 40MZB540/38MZA150(2x)/38MZA240 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 36720 - 0.13 16 18 20 22 16 18 20 22 16 18 127911 133488 141312 128890 129984 137820 144658 134659 135857 C.S. 122062 112183 94323 78555 128890 123435 105389 86064 134659 122952 C.T.R. 153393 158113 165521 173354 160936 161978 169274 177469 167369 166961 39,3 39,8 40,4 41,0 39,9 39,7 40,7 41,3 40,4 40,5 117935 122758 129616 136938 124871 127033 133189 140870 130279 131033 C.S. 116214 109507 93037 76153 124871 124376 103783 84770 130278 128128 C.T.R. 151573 156865 164280 171982 159490 161182 168309 176419 165536 166250 T.S.C. C.T. 44,4 45,0 45,6 46,1 45,2 45,3 45,8 46,5 45,5 45,5 115087 118601 125500 134145 121270 122554 128488 137714 126421 126550 C.S. 115084 106708 91224 76770 121269 121633 102056 84819 126407 126540 C.T.R. 151709 155471 162895 172117 158628 159974 166270 176100 164349 164550 T.S.C. C.T. 40 30600 - 0.07 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 122070 C.T. 35 24480 - 0.06 C.T. T.S.C. 30 VAZÃO DE AR NO EVAPORADOR - (m3/h) - FATOR BY-PASS 49,7 50,1 50,7 51,3 50,3 50,3 50,9 51,6 50,7 50,8 112161 114421 120980 128864 119285 117811 124817 130880 123490 122483 C.S. 112150 104881 89121 73241 119285 116883 101141 81174 123490 122479 C.T.R. 151522 154177 161216 169564 159171 158095 165543 172029 164444 163422 T.S.C. 54,7 55,1 55,7 56,2 53,3 55,4 55,9 56,6 55,8 55,8 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 40MZB630/38MZA240(2x)/38MZA150 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) VAZÃO DE AR NO EVAPORADOR - (m3/h) - FATOR BY-PASS 28560 - 0.06 30 35 40 342840 - 0.13 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 25 35700 - 0.07 18 20 22 16 18 20 22 16 18 C.T. 142291 147694 155995 164456 150367 152086 160043 168661 156381 156329 C.S. 142291 130320 111695 92603,8 150367 146275 124899 101861 156381 156329 C.T.R. 174254 180143 189169 198339 183019 184909 193557 202910 189565 189509 T.S.C. 38,9 39,3 39,9 40,5 39,4 39,6 40,2 40,8 39,9 39,9 C.T. 139173 143638 151778 160179 146881 147971 155551 164064 152601 152574 C.S. 139173 128488 110058 91046,8 146881 143830 123067 100272 152601 152573 C.T.R. 174233 179130 188067 197273 182665 183874 192212 201538 188939 188904 T.S.C. 44,2 44,6 45,2 45,8 44,8 44,9 45,5 46,1 45,2 45,2 C.T. 135648 139309 147202 155471 143126 143829 150893 159088 148515 148497 C.S. 135648 126386 108174 89282,7 143126 141517 121246 98526,4 148515 148496 C.T.R. 173927 178010 186730 195885 182200 182997 190818 199896 188148 188128 T.S.C. 49,3 49,7 50,4 51,0 49,9 50,0 50,7 51,3 50,4 50,4 C.T. 132063 135161 142626 150509 139057 139432 146030 153841 144258 145029 C.S. 132062 124457 106654 87502,3 139057 138499 119312 96657,7 144258 141898 C.T.R. 173787 177284 185592 194390 18159 182012 189399 198114 187376 188249 T.S.C. 54,5 54,8 55,4 56,0 55,1 55,1 55,7 56,3 55,5 55,5 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 22 40MZB240/38ABA240 TEMPERATURADE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 16320 - 0.10 16 18 20 22 16 18 20 22 16 18 20 22 57059 60353 63616 58063 58847 61912 65281 60465 60456 63028 66341 C.S. 54909 50293 43136 35747 58063 56503 48267 39360 60465 60456 53112 42855 C.T.R. 66249 68538 72058 75542 69612 70450 73719 77321 72181 72174 74912 78442 35,7 36,1 36,6 37,1 36,2 36,4 36,9 37,5 36,6 36,6 37,1 37,7 C.T. 53754 55531 58855 62204 56893 57441 60363 63708 59178 59170 61484 64760 C.S. 53754 49631 42535 35226 56893 55740 47631 38813 59178 59170 52509 42290 C.T.R. 66169 68173 71669 75288 69558 70150 73293 76908 72019 72010 74497 78042 40,8 41,7 41,8 42,4 41,4 41,5 42,0 42,6 41,8 41,8 42,3 42,8 C.T. 52379 53956 57092 60534 55465 55732 58584 61962 57708 57630 59659 62979 C.S. 52379 48837 41838 34624 55465 54733 46898 38211 57708 57630 51747 41662 C.T.R. 66052 67806 71190 74811 69392 69699 72795 76360 71727 71732 73964 77469 T.S.C. 40 13600 - 0.07 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 54909 T.S.C. 35 10880 - 0.06 C.T. T.S.C. 30 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 46,6 47,0 47,5 47,4 47,0 47,1 47,6 47,7 46,9 47,3 47,8 47,9 C.T. 51051 52384 55347 58615 53951 54047 56860 60091 56091 56096 57830 61004 C.S. 51051 48143 41122 33932 53951 53732 46245 37562 56091 56096 51011 40986 C.T.R. 65968 67481 70717 74276 69164 69265 72308 75727 71487 71492 73444 76884 T.S.C. 51,8 52,2 52,7 53,1 52,3 52,3 52,6 52,7 52,6 52,6 53,1 53,5 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 40MZB300/38ABA300 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 30 35 40 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 13600 - 0.06 17000 - 0.07 20400 - 0.10 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 18 20 22 16 18 C.T. 70213 73285 76830 80612 73962 75158 78830 82480 76629 76728 80063 C.S. 70213 63387 54243 44911 73962 71170 60467 49209 76629 76728 66278 C.T.R. 86226 89596 93478 97624 90331 91642 95680 99688 93252 93362 97027 T.S.C. 38,4 39,2 39,2 39,4 38,8 39,1 39,4 39,5 38,9 39,0 39,4 C.T. 68744 71355 74928 78536 72187 73203 76737 80396 74969 74929 77951 C.S. 68744 62571 53320 44074 72187 69803 59591 48447 74969 74929 65392 C.T.R. 86525 8954 93349 97301 90299 91433 95329 99363 93377 93333 96659 T.S.C. 44,1 44,9 45,2 45,5 44,6 44,9 45,4 45,7 44,9 44,9 45,5 C.T. 66987 69102 72687 76250 70281 70968 74394 78055 72964 72903 75581 C.S. 66987 61451 52375 43260 70281 68611 58645 47633 72964 72903 64332 C.T.R. 86651 88979 92935 96872 90245 91019 94808 98872 93212 93144 96126 T.S.C. 49,9 50,3 50,8 51,3 50,3 50,5 51,0 51,4 50,6 50,6 51,2 C.T. 64939 66664 70175 73700 68163 68574 71776 75333 70581 70648 72891 C.S. 64939 60081 51513 42311 68163 67003 57597 46703 70581 70647 63311 C.T.R. 86498 88433 92328 96214 90066 90543 94094 98031 92714 92830 95327 T.S.C. 55,2 55,6 56,1 56,5 55,6 55,8 56,3 56,7 55,9 56,1 56,4 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 23 20 22 16 18 20 40MZB390/38ABA390 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) C.T. 25 C.S. C.T.R. T.S.C. C.T. 30 C.S. C.T.R. T.S.C. C.T. 35 C.S. C.T.R. T.S.C. C.T. 40 C.S. VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 17880 - 0.05 22100 - 0.07 26520 - 0.11 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 18 20 22 16 18 20 22 16 18 89802 93717 98971 104602 95022 96357 101816 107339 98926 98968 89802 81706 70042 58287 95022 91534 78308 63985 98926 98968 109288 113541 119198 125240 114914 116370 122262 128208 119119 119164 34,8 35,1 35,4 35,5 35,1 35,2 35,5 35,7 35,2 35,2 87947 91177 96494 101867 92802 93879 99049 104569 96738 96730 87947 80583 69083 57254 92802 90263 77207 62984 96738 96730 109384 112889 118672 124466 114606 115804 121419 127411 118893 118885 40,4 40,7 41,0 41,2 40,6 40,8 41,1 41,4 40,9 40,9 85886 88471 93377 99026 90602 91224 96139 101652 94255 94246 85886 79306 67909 56213 90602 89033 76143 62025 94255 94245 109344 112190 117498 123689 114488 115172 120554 126611 118460 118470 45,8 46,1 46,3 46,7 46,1 46,2 46,6 47,0 46,3 46,4 83625 85817 90840 96073 88316 88706 93163 98444 91678 91615 83625 78001 66769 55146 88316 87156 74805 60952 91677 91614 C.T.R. 109225 111663 117199 123025 114394 114849 119745 125546 118054 118120 T.S.C. 51,0 51,3 51,7 52,3 51,4 51,5 51,9 52,2 51,6 52,0 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 40MZB480/38ABA480 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO (OC) 25 30 35 40 VAZÃO DE AR NO EVAPORADOR - FATOR BY-PASS 21760 - 0.05 27200 - 0.06 32640 - 0.13 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 18 20 22 16 C.T. 18 20 22 106143 110031 116191 122755 C.S. 106143 97972 83778 69439 C.T.R. 131252 135500 142386 T.S.C. 35,4 36,0 36,3 C.T. 104065 107015 113410 119517 C.S. 104065 96547 82741 68367 C.T.R. 131314 134673 141819 148602 T.S.C. 41,2 41,9 42,5 41,2 C.T. 101612 103994 110317 C.S. 101612 94995 81490 C.T.R. 131327 134073 T.S.C. 47,5 47,9 C.T. 99190 C.S. 99190 C.T.R. T.S.C. 111978 113089 119269 125724 116664 116591 111978 109452 93721 76352 116663 116590 149462 137715 138953 145809 153026 142719 142970 36,3 35,9 36,2 36,5 37,2 35,6 36,5 109874 110266 116873 122744 113933 113903 109873 107749 93512 75329 113933 113903 138471 138116 146340 151882 142177 142203 42,3 41,1 43,0 41,7 41,4 41,3 116489 107065 107613 113024 119394 111243 111195 67158 107065 106480 91272 74122 111243 111194 141064 147824 137394 138066 144055 151049 141999 141946 48,0 47,7 47,6 47,9 48,1 47,7 47,6 47,6 101341 107200 113363 104612 104903 109725 115930 108463 108429 93618 80207 66031 104612 104081 89970 72903 108462 108429 131505 133976 140538 147461 137627 137937 143380 150331 141872 141878 53,0 53,3 53,6 54,0 53,4 53,5 53,8 54,1 53,5 53,7 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 24 16 18 TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO ( OC) 25 30600 - 0.07 36720 - 0.13 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 18 20 22 16 18 20 22 16 18 129451 136658 144326 131159 133077 140544 148093 136504 136585 C.S. 123977 112523 96497 80301 131159 126120 107808 88120 136504 136585 C.T.R. 150429 156368 164137 172390 158174 160261 168329 176477 163939 164026 34,7 35,1 35,4 35,6 35,1 35,2 35,5 35,8 35,2 35,2 C.T. 121393 126001 133231 140594 128094 129658 136746 144293 133464 133469 C.S. 121393 111002 95141 78884 128093 124284 106300 86733 133464 133469 C.T.R. 150544 155540 163408 171362 157763 159491 167196 175397 163613 163619 40,2 40,5 40,9 41,2 40,5 40,7 41,0 41,4 40,8 40,8 118563 122244 128708 136654 125004 125932 132711 140256 130064 130050 C.S. 118563 109245 93419 77432 125004 122857 104777 85390 130063 130049 C.T.R. 150527 154563 161534 170260 157545 158564 165975 174259 163049 163054 C.T. 45,5 45,8 46,1 46,6 45,9 46,0 46,4 46,9 46,2 46,2 115309 118407 125316 132494 121759 122374 128517 135737 126401 126301 C.S. 115309 107353 91875 75931 121759 119971 102917 83833 126400 126301 C.T.R. 150221 153651 161253 169287 157319 158022 164758 172687 162377 162506 T.S.C. 50,7 51,0 51,4 52,2 51,1 51,2 51,6 52,1 51,4 51,9 T.S.C. C.T. 40 24480 - 0.06 123977 T.S.C. 35 Vazão de Ar no Evaporador - ( m3/h) - Fator de By-Pass C.T. T.S.C. 30 40MZB540/38ABA390/38ABA150 e 40MZA540/38ABA300/38ABA240 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) TEMPERATURA DE ENTRADA DO AR DE CONDENSAÇÃO ( OC) 25 30 35 40 40MZB630/38ABA390/38ABA240 e 40MZA630/38ABA480/38ABA150 Vazão de Ar no Evaporador - ( m3/h) - Fator de By-Pass 28560 - 0.06 35700 - 0.07 42840 - 0.13 TEMPERATURA DE BULBO ÚMIDO NO EVAPORADOR (ºC) 16 18 20 22 16 18 20 22 16 18 C.T. 143705 149899 158355 C.S. 143705 131034 112291 167473 152083 154144 162951 171865 158378 158421 93445 152083 146733 125620 102612 158378 158421 C.T.R. 175349 182085 T.S.C. 34,9 35,2 191180 200939 184375 186626 196121 205701 191143 191191 35,4 35,4 35,1 35,2 35,4 35,5 35,1 35,1 C.T. 140761 C.S. 140761 145777 154400 163052 148532 150176 158500 167409 154894 154866 129206 110787 91783 148532 144782 123846 101017 154894 154866 C.T.R. T.S.C. 175520 180968 190340 199659 183869 185708 194743 204404 190798 190767 40,6 40,8 41,1 41,3 40,7 40,9 41,2 41,4 41,0 41,0 C.T. 137446 141467 149635 158523 145063 145990 153862 162751 150895 150881 C.S. 137446 127155 109012 90131 145063 142533 122197 99500 150895 150879 C.T.R. 175417 179860 188723 198447 183735 184753 193385 203156 190068 190095 T.S.C. 46,0 46,3 46,5 46,9 46,3 46,4 46,8 47,1 46,5 46,6 C.T. 133965 137398 145461 153885 141497 142043 149186 157709 146876 146789 C.S. 133965 125161 107159 88454 141497 139832 120072 97860 146875 146788 C.T.R. 175372 179208 188107 197440 183683 184335 192192 201557 189534 189600 T.S.C. 51,3 51,6 52,0 52,5 51,6 51,8 52,1 52,4 51,8 52,1 C.T. - Capacidade Total ( kcal/h) C.S. - Capacidade Sensível (kcal/h) C.T.R. - Calor Total Rejeitado ( kcal/h) T.S.C. - Temperatura Saturada de Condensação (°C) 25 8 - CURVAS DE VAZÃO 8.1 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 240 * Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos. 8.2 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 300 * Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos. 26 8.3 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 390 * Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos. 8.4 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 480 * Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos. 27 8.5 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 540 * Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos. 8.6 - CURVAS DE VAZÃO - MÓDULO DE VENTILAÇÃO 630 * Régua de recuperação da pressão dinâmica considerando a velocidade nos dutos de 8m/s. A parcela de recuperação desta pressão é função do projeto de dutos. 28 9 - DADOS PARA INSTALAÇÃO DIÂMETRO DA LINHA Circuito 150 1 3/8” ATÉ 18m 1 5/8” ACIMA DE 18m DE SUCÇÃO Circuito 240 1 5/8” ATÉ 18m 2” ACIMA DE 18m DIÂMETRO DA LINHA Circuito 150 5/8” ATÉ 24m 3/4” ACIMA DE 24m DE LÍQUIDO Circuito 240 5/8” ATÉ 10m 7/8” ACIMA DE 10m COMPRIMENTO MÁXIMO TUBULAÇÃO 30m (COMPRIMENTO EQUIVALENTE POR CIRCUITO) DESNÍVEL MÁXIMO ENTRE UNIDADES 15m CARGA DE REFRIGERANTE 40MZB240 - 38MZA240 12,7kg CONDENSADORA + EVAPORADORA 40MZB300 - 38MZA150 8,1kg - 38MZA150 8,1kg 40MZB390 - 38MZA150 8,8kg - 38MZA240 12,9kg 40MZB480 - 38MZA240 13,5kg - 38MZA240 13,5kg 40MZB540 - 38MZA150 8,4kg - 38MZA150 8,4kg - 38MZA240 12,8kg 40MZB630 - 38MZA150 8,2kg - 38MZA240 12,8kg - 38MZA240 12,8kg 40MZB240 - 38ABA240 9,2kg 40MZB300 - 38ABA300 7,6/7,6kg (Circ. 150/ Circ.150) 40MZB390 - 38ABA390 8,7/11,6kg (Circ. 150/ Circ. 240) 40MZB480 - 38ABA480 9,8/9,8kg (Circ. 240/ Circ. 240) 40MZB540 - 38ABA150 + 38ABA390 8,2/ 8,2/ 12,6kg (Circ. 150/ Circ. 150/ Circ. 240) - 38ABA240 + 38ABA300 12,6/ 8,2/ 8,2kg (Circ. 240/ Circ. 150/ Circ. 150) 40MZB630 - 38ABA150 + 38ABA480 7,9/ 11,9/ 11,9kg (Circ. 150/ Circ. 240/ Circ. 240) - 38ABA240 + 38ABA390 11,9/ 11,9/ 7,9kg (Circ. 240/ Circ. 240/ Circ. 150) ACRÉSCIMO DE GÁS 200g A MAIS PARA CADA METRO DE TUBULAÇÃO POR CIRCUITO ACRÉSCIMO DE ÓLEO ACIMA DE 20m ACRESCER ÓLEO NA RAZÃO DE 1 A 2% EM PESO DA CARGA DE REFRIGERANTE ESTES VALORES SÃO APENAS PARA REFERÊNCIA DEVENDO A CARGA DE GÁS SER VERIFICADA PELAS MEDIÇÕES DE SUB-RESFRIAMENTO E SUPERAQUECIMENTO. 10 - TABELA DE UTILIZAÇÃO DAS CONDENSADORAS As unidades 40MZB(V+T) podem ser utilizadas com condensadoras remotas com ventilador centrífugo ou axial segundo as combinações abaixo. Evaporadora Vent. Centrifugo Evaporadora 40MZB (V+T) 38MZ150 240 38MZ240 38AB150 38AB240 1 300 2 390 1 480 540 Condensador Vent Axial 38AB300 38AB390 1 1 1 1 2 2 38AB480 1 540 - - 630 1 2 630 - - 1 1 1 1 1 1 1 1 29 1 11 - TABELA DE DISPONIBILIDADE DE ITENS POR PADRÃO DE ESPECIFICAÇÕES ITEM PADRÃO STANDARD - S COMPRESSORES SCROLL D FILTRAGEM G2 DE FIBRA 1” D BANDEJA DE CONDENSADO EM CHAPA DE AÇO D TERMOSTATO COM CHAVE DE ACIONAMENTO O PRESSOSTATO MINIATURIZADO NO LADO DE ALTA E BAIXA D FILTRO DE SUCÇÃO (SÓLIDOS) NA ENTRADA DO COMPRESSOR D QUADRO ELÉTRICO D VÁLVULAS 1/4” SERVIÇOS NAS L. SUCÇÃO, LÍQUIDO E DESCARGA D FILTRO SECADOR D VÁLVULA DE EXPANSÃO TERMOSTÁTICA D CLO-RELÉ ANTICICLAGEM D ACIONAMENTO P/ AQUECIMENTO O CAIXA DE MISTURA O D - DISPONÍVEL N - NÃO DISPONÍVEL O - OPCIONAL 30 A critério da fábrica, e tendo em vista o aperfeiçoamento do produto, as características daqui constantes poderão ser alteradas a qualquer momento sem aviso prévio. www.carrierdobrasil.com.br CT 40MZB 240 a 630 - K - 05/09