IBM PureSystems
SKiLLs – Webcast
2012
Jacob Fred
Channel Technical Sales Specialist
IBM Systems and Technology Group
Tel: +55 11 2322 7089
Mobile: +55 11 97597 9133
Tie Line 740 7089
E-mail: [email protected]
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM PureFlex Systems
IBM Flex System Overview
This document is for IBM and IBM Business Partner use only
xtw280t1
Abril 2012
© 2012 IBM Corporation
Agenda
 IBM Flex System Overview
 IBM Flex System Enterprise Chassis Overview
 Nodes Overview
 I/O Overview
 Management Overview
 Power Overview
 Cooling Overview
 Rack Overview
 Soluções Oferecidas
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System Overview
 Proteção de investimento de avançada tecnologia por diversos anos
– Novos processadores, memória, I/O, Storage
– Barramentos internos de maior velocidade
– I/Os ainda mais rápidos
 Novo IBM Flex System Manager
– Suportado para gerenciar múltiplos IBM Flex System Enterprise Chassis




Novos Compute e Storage Systems
Novos Scalable Switch Elements (ScSE) e I/O adapters
Novo IBM Flex System Enterprise Chassis Management Module
Mais eficiência de energia e sistema de resfriamento
– Componentes de máxima eficiência
– Sofisticado e prático controle do sistema
– Compatível com futuras instalações de infraestrutura
de Data Centers de alta eficiência
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System Enterprise Chassis - Overview
 Chassis
– 10 U (Rack Units)
– 14 baias de Nodes
• Suporte para Nodes de tamanhos half e full
• Suporte para Nodes duplos
• Suporta interconexão de Nodes de expanção
–
–
–
–
4 baias de Switch
2 baias de Gerenciamento
6 Power Supplies (2 já inclusas)
10 baias de FANs
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System Enterprise Chassis - Frente
Storage node
Half node
Full node
Manager node
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System Enterprise Chassis - Trás
40 mm Fans (2X)
80 mm Fan
Packs (8X)
IBM Flex
System
Enterprise
Chassis
Management
Modules (2X)
Fan Mux
Card (2X)
Power Supplies (6X)
Scalable Switch Elements (4X)
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System Enterprise Chassis - Baias
Shuttle
IBM Flex System
Enterprise Chassis
Node Bay Shelf
- Remove para Node Full Wide
- Remove dois Shelves para Node Full Wide, Double High
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Compute Nodes - Flex System Manager
 IBM Flex System Manager (8731)
– Appliance de gerenciamento
– Node de baia Half-wide
– 2 sockets Sandy Bridge-EP
• 1 – 8 Cores 2.0GHz 20MB L3 95W
– 24 LP DDR3 DIMM Sockets / 1600MT/s
• 32GB DDR3 SDRAMS
– 8x 4GB
– 1x HS 2.5” 1TB SAS HDD
– 2x 1.8” 200GB SSDs (RAID 1)
– Systems Management Software Stack
• Ferramenta de fácil implementação
• Ferramentas de Automação de Virtualização
• Ferramentas de Migração de Workload
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Compute Nodes - Flex System Manager
IBM PureApplication System
 IBM Flex System Manager (7955)
– Appliance de gerenciamento
– Node de baia Half-wide
– 2 sockets Sandy Bridge-EP
• 2 – 8 Cores 2.0GHz 20MB L3 95W
– 24 LP DDR3 DIMM Sockets / 1600MT/s
• 192GB DDR3 SDRAMS
– 24x 8GB
– 1x HS 2.5” 1TB SAS HDD
– 2x 1.8” 200GB SSDs (RAID 1)
– IBM Flex System CN4054
10Gb Virtual Fabric Adapter
– IBM Flex System FC3172 2-port 8Gb FC Adapter
– Systems Management Software Stack
– IBM Workload Deployer
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Compute Nodes - Intel EP
 IBM Flex System x240 Compute Node
–
–
–
–
Node de baia Half-wide
2 sockets Sandy Bridge-EP
24 LP DDR3 DIMMs / 1600MT/s
2 HS 2.5” SAS/SATA HDDs or SSDs
Frente
Trás
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Compute Nodes - POWER 7
 IBM Flex System p260 Compute Node
– Node de baia Half-wide
– 2 sockets POWER 7
• 64-bit Power7 RISC processor 190w
• 8 cores
– 16 VLP DIMMs DDR3, 1066MT/s, 256GB Max
– 2x 2.5 SAS/SATA HDDs ou SSDs
 IBM Flex System p460 Compute Node
– Node de baia Full wide
– 4 sockets POWER 7
• 64-bit Power7 RISC processor 190w
• 4 / 8 cores
– 32 VLP DIMMs DDR3, 1066MT/s, 256GB Max
– 2x 2.5 SAS/SATA HDDs ou SSDs
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System V7000 Storage Node
 IBM Storewize V7000 Storage System
– Node de baias Double High / Full Width
– 24x 2.5” HDDs ou SSDs
– Duas controladoras hot swappable para alta disponibilidade
Frente
Trás
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Compute Nodes - I/O
 Ethernet
–
–
–
–
–
IBM Flex System EN2024 4-port 1Gb Ethernet Adapter
IBM Flex System EN4054 4-port 10Gb Ethernet Adapter
IBM Flex System CN4054 10Gb Virtual Fabric Adapter
IBM Flex System CN4054 Virtual Fabric Adapter
IBM Flex System EN4132 2-port 10Gb Ethernet Adapter
PeX
P somente
X somente
X somente
X somente
 FibreChannel
– IBM Flex System FC3172 2-port 8Gb FC Adapter
– IBM Flex System FC5022 2-port 16Gb FC Adapter
– IBM Flex System FC3052 2-port 8Gb FC Adapter
PeX
X somente, P futuro
P* e X
 InfiniBand
– IBM Flex System IB6132 2-port QDR InfiniBand Adapter
– IBM Flex System IB6132 2-port FDR InfiniBand Adapter
P somente
X somente
* Não suportado com AIX
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
I/O - Scalable Switch Element (ScSE)
 Ethernet I/O
–
–
–
–
IBM Flex System EN4091 10Gb Ethernet Pass-thru
IBM Flex System EN2092 1Gb Ethernet Scalable Switch
IBM Flex System EN4093 10Gb Virtual Fabric Scalable Switch
FoD Enhancement Licenses
 FibreChannel I/O
– IBM Flex System FC5022 16Gb SAN Scalable Switch
– IBM Flex System FC5022 16Gb ESB SAN Scalable Switch
– FoD Enhancement Licenses
 InfiniBand I/O
– IBM Flex System IB6131 InfiniBand Switch
– FoD Enhancement Licenses
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System
Enterprise Chassis Management Module
 Monitors IBM Flex System
Operating Parameters
 Coleta de inventário
 Atualização de Firmwares
 Gerenciamento Low Level
de Nodes
 Configuração L2 de Switch e
gerenciamento
 Interface de usuário Web,
CLI, SNMP, CIM
Para redundância, utilize dois
Enterprise Chassis
Management Module
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System - Power Supplies








Suporte para até 6 Power Supplies
Inclui 2 Power supplies por padrão
I2C Managed Element
2500W
208 - 240VAC Input Range
12.2VDC 205A - 225A Output Range
92% eficiência em plena carga
Redundância N+M, N+N, N+1
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Cooling








Resfriamento direcionado - Nodes (esq./ dir.), switches
Escalável / Expansível
2x FANs de 40mm para ScSEs (Scalable Switches)
Até 8 FANs de 80mm para Nodes (4 inclusos)
Controle de resfriamento adaptável
Acústica avançada e otimizada
Fan Multiplexer Card
Eficiência líde de indústria
Melhoria das características
de operacionalidade
40mm Fan
This document is for IBM and IBM Business Partner use only
80mm Fan
© 2012 IBM Corporation
IBM 42U 1100mm Deep Dynamic Rack
 Novo IBM Rack otimizado
– 100mm mais fundo que os racks
padrões, ocupando 2 placas de
piso elevado
– Nova porta com dissipador de
calor disponível
 Trilhos do chassis de fácil
instalação
 Orgnização de cabos aprimorado
– Ampla saída de cabos
– Pistas de cabos da frente para trás
 6 encaixes laterais de PDU
Cable
Egress
Rear PDU
Access 6x
Cable
Channels
Strip PDU
Support 4X
Cable Tie
Points
Cable
Egress
Thermal
Sealing Plane
(front EIA
flange)
Cable
Channels
Cable
Egress
Outrigger
Front of
Rack
Rear of
Rack
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM PureFlex
Config mínima
Hardware
Rack
Chassis
Power Supplies / Fans
Ethernet Switch
TOR Switch
FC Switch
FSM HW
V7000 HW
INode
Mezz cards
Software
V7000 SW
FSM SW
OS
PowerVM (Power only)
PowerSC (Power only)
Smart Cloud Entry
Services
SWMA
HWMA
MTS
Lab Services
Express
Standard
Enterprise
Incluso
Incluso
2/4
BNT 10GB
n/a
QLogic 8GB
Incluso
Incluso
com Drives
P260 ou x
FC, Enet
Incluso
Incluso
4/6
BNT 10GB
n/a
QLogic 8GB (2)
Incluso
Incluso
com Drives
P260 / p460 ou x
FC(2), Enet
Incluso
Incluso
6/8
BNT 10GB (2)
2 Eth,2 FC – somente Power
QLogic 8GB (2)
Incluso
Incluso
com Drives
Dois p460 ou Dois x
FC(2), Enet (2)
Incluso
Incluso
Incluso
Incluso
Incluso
opcional
Incluso
Incluso
Incluso
Incluso
Incluso
Incluso / possível deselecionar
Incluso
Incluso
Incluso
Incluso
Incluso
Incluso / possível deselecionar
1 ano 9x5
3 anos 9x5 default
1 ano 9x5 selectable
3 ano 9x5
3 anos microcode (1)
WSU 24x7
Account Advocate 9x5
5 dias
3 anos 9x5
3 ano 9x5
3 anos microcode (1)
3 dias
This document is for IBM and IBM Business Partner use only
3 anos 9x5
3 anos microcode (2)
WSU 24x7
Account Advocate 24x7
7 dias
© 2012 IBM Corporation
IBM PureFlex
IBM PUREFLEX SYSTEM
FEATURE
CODE
EXPRESS
STANDARD
ENTERPRISE
DESCRIPTION
1
1
1
1
1
2
#3593
IBM FLEX System EN4093 10 Gb Virtual Fabric Scalable Switch
2
#3596
Port Upgrade1 for #3593
2
#3597
Port Upgrade 2 for #3593
Flex System Enterprise Chassis (7893-92X), with the following features:
1
2
2
#3595
IBM Flex System FC3171 8 Gb SAN Switch
2
4
4
#3282
10 GbE SFP+ Transceiver
2
4
8
#3286
8 GB SFP+ Transceiver
5
5
6
#EB29
1000Base-T SFP RJ45 Transceiver
1
1
1
#9039
Base CME
1
1
1
#3592
Redundant CME
2
2
2
#9059
Base Power Module (2X)
2
4
#3590
Redundant Power Module
2
4
6
#4558
Power Cord (2.5M) to PDU/UPS
1
1
1
#9038
Base Fans (4X)
1
2
#7805
Additional Fans (2X)
2
2
#1111
CAT5E Ethernet Cable, 3M Blue
4
#ECB4
10 GbE SFP+ Copper DAC Cable,1 M
1
#EFM1
Open Fabric Manager
2
1
1
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM PureFlex
IBM PUREFLEX SYSTEM
FEATURE
CODE
EXPRESS
STANDARD
ENTERPRISE
DESCRIPTION
1
1
1
1
1
1
#EB31
Platform Manager S/W Bundle
4
4
4
#EM09
32 GB Memory
2
2
2
#1771
IBM 200 GB 1.8" SATA SSD
1
1
1
#3767
1TB 7.2K RPM 2.5" SATA Disk Drive
1
1
2
1
1
1
Flex System Manager (FSM) (7955-01M), with the following features:
Flex System x240 Compute Node (7863-10X), with the following features:
#EN20
or
Compute Node with 10Gb Virtual Fabric
or
1
1
1
#EN21
Compute Node without 10Gb Virtual Fabric
1
1
1
#EM05 or
#EEM2
1
1
1
#1759
IBM Flex System CN4054 10 Gb Virtual Fabric Adapter (Not required with
#EN20)
1
1
1
#1764
IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter
1
1
1
#EBK2
IBM Flex System x240 USB Enablement Kit
1
1
1
#EBK3
2 GB USB Hypervisor Key (VMWare 5.0)
4 GB minimum memory
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM PureFlex
IBM PUREFLEX SYSTEM
FEATURE
CODE
EXPRESS
STANDARD
ENTERPRISE
DESCRIPTION
1
1
1
1
1
1
#0010
Storwize V7000 S/W Preload
2
4
4
#5305
1M or 5M Fiber Optic Cable
8
8
8
#3206
600 GB 2.5-inch 20k HDD
2
2
4
#3512 or #3214
2
2
2
#6008
Cache 8 GB
1
1
1
#9730
Power Cord - PDU Connection
2
2
2
#9801
AC Power Supply
1
1
1
2
2
2
#7189 or #7196
Optional PDUs
1
1
1
#EC02 or #EC05
Rack Rear Door or RDHX
1
1
1
#EC03
Side Doors
1
1
1
#EC06
Rack Front Door
Storwize V7000 Disk System (2076-124), with the following features:
200 or 400 GB 2.5-inch SSD
Flex System Enterprise Rack (7953-94X), with the following features:
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM SmartCloud Entry
 Self Service Private Cloud Portal
 Permite o cliente:
–
–
–
–
–
Provisionar (implantação) e de-provisionar servidores virtuais
Elaboração e clone de workloads virtualizados
Tirar workloads snapshots
Inicializando e desligando servidores virtuais como parte de um workload
Redimensionando servidores virtuais existentes
Estes e muitos outros features estão inclusos
nesta versão do IBM SmartCloud Entry
https://www.ibm.com/developerworks/mydeveloperworks/wikis/home/wiki/W21ed5ba0f4a9_46f4_9626_24cbbb86fbb9?lang=en
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM PureApplication System - High Performance Model
Cable ingress / egress
Storage Controller
IBM Storwize V7000 Disk System
4 x 400 GB SAS SSD per enclosure
20 x 600 GB SAS HDD per enclosure
BNT 64 PT Enet SW
BNT 64 PT Enet SW
V 7000 Expansion
V 7000 Controller
V 7000 Expansion
V 7000 Controller
Intel Compute Intel Compute
Intel Compute Intel Compute
New Chassis
Common Management Module
2x 10Gb Ethernet Switch
2x 16 Gb FC Switch
Intel Compute Intel Compute
Intel Compute Intel Compute
PDU
PDU
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
IBM PureApplication System
Management Node
IBM Workload Deployer
Intel Compute Intel Compute
MGMT
MGMT
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
VM Management Node
Intel Compute Intel Compute
Intel Compute Intel Compute
MGMT
http://www-01.ibm.com/software/webservers/workload-deployer/
MGMT
Cable ingress / egress
PDU
PDU
Intel Compute Intel Compute
42 U
41 U
40 U
39 U
38 U
37 U
36 U
35 U
34 U
33 U
32 U
31 U
30 U
29 U
28 U
27 U
26 U
25 U
24 U
23 U
22 U
21 U
20 U
19 U
18 U
17 U
16 U
15 U
14 U
13 U
12 U
11 U
10 U
9 U
8 U
7 U
6 U
5 U
4 U
3 U
2 U
1 U
This document is for IBM and IBM Business Partner use only
Top of Rack Switches
BLADE Network Technologies Top of
Rack Switches
Customer Data Center & Rack-to-rack
communications
V7000 Disk Expansion
Per enclosure:
4 x 400 GB SAS SSD
20 x 600 GB SAS HDD
Intel Compute
2.6 GHz 8C Intel processor, 110 W
256 KB L2 per core
4 MB eDRAM L3 per core
2x 4 Port 10 GbE
2x 2 Port 8 Gb/s FC
Overall
Power
~30 KW
Cores
608 Cores
Memory
SSD
Storage
9.7 TB
6.4 TB (unformatted)
48.0 TB (unformatted)
© 2012 IBM Corporation
IBM PureApplication – Soluções Oferecidas
Small Part #5
(Part 1)
Enet SW 64 PT
Enet SW 64 PT
V7000 Expansion
V7000 Expansion
V7000 Controller
V7000 Controller
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Cores/Threads
PVUs
Memory (GB)
Raw SSD/HDD (TB)
Usable SSD/HDD (TB)
PDU L Volt
PDU H Volt
Power (Max)
Application Services
96/384
9600
1536
6.4 / 48
4.8 / 38.4
4x60A 3ph
4x32A 3ph
10.6 kW
Included
42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
9U
8U
7U
6U
5U
4U
3U
2U
1U
Medium
(Part 2)
Enet SW 64 PT
Enet SW 64 PT
V7000 Expansion
V7000 Expansion
V7000 Controller
V7000 Controller
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Part #6
42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
9U
8U
7U
6U
5U
4U
3U
2U
1U
192/768
19200
3072
6.4 / 48
4.8 / 38.4
4x60A 3ph
4x32A 3ph
14.4 kW
Included
This document is for IBM and IBM Business Partner use only
Large
(Part 3) Part #7
Enet SW 64 PT
Enet SW 64 PT
V7000 Expansion
V7000 Expansion
V7000 Controller
V7000 Controller
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7
FW
Firebird
4S
Compute Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird 4S
P7 FW Firebird 4S
384/1536
38400
6144
6.4 / 48
4.8 / 38.4
4x60A 3ph
4x32A 3ph
22.2 kW
Included
42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
9U
8U
7U
6U
5U
4U
3U
2U
1U
Enet SW 64 PT
Enet SW 64 PT
V7000 Expansion
V7000 Expansion
V7000 Controller
V7000 Controller
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7
FW
Firebird
4S
Compute Nodes
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7
FW
Firebird
4S
Compute Nodes
P7 FW Firebird
4S
Compute
Nodes
P7
FW
Firebird
4S
Compute Nodes
P7 FW Firebird
4S
Compute
Nodes
Mgmt
Mgmt
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7 FW Firebird
4S
Compute
Nodes
P7
FW
Firebird
4S
Compute Nodes
P7 FW Firebird
4S
Compute
Nodes
42U
41U
40U
39U
38U
37U
36U
35U
34U
33U
32U
31U
30U
29U
28U
27U
26U
25U
24U
23U
22U
21U
20U
19U
18U
17U
16U
15U
14U
13U
12U
11U
10U
9U
8U
7U
6U
5U
4U
3U
2U
1U
608/2432
60800
9728
6.4 / 48
4.8 / 38.4
4x60A 3ph
4x32A 3ph
31.2 KW
Included
© 2012 IBM Corporation
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
IBM Flex System – Tour Virtual
•
Enterprise Chassis
http://www03.ibm.com/systems/data/flash/flex/virtualtours/chassis/index.html
•
x240 Compute node
http://www03.ibm.com/systems/data/flash/flex/virtualtours/compute-nodes/x240/index.html
•
x440 Compute node
http://www03.ibm.com/systems/data/flash/flex/virtualtours/compute-nodes/x440/index.html
•
p460 Compute node
http://www03.ibm.com/systems/data/flash/flex/virtualtours/compute-nodes/p460/index.html
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
PureSystems - Webcasts Brasil 2H-2012
Foco na certificação técnica
Skill 1 - IBM PureFlex Systems - Posicionamento (Técnico/Comercial)
Dia: 16/08/2012
Horário: das 10:00h às 11:30h
Link de inscrição:
https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpru&lang=pt-BR
Skill 2 - IBM PureFlex Systems - IBM Flex System Enterprise Chassis Overview (Técnico)
Dia: 23/08/2012
Horário: das 10:00h às 11:30h
Link de inscrição:
https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpta&lang=pt-BR
Skill 2 - IBM PureFlex Systems - IBM Flex System Nodes Overview
Dia: 30/08/2012
Horário: das 10:00h às 11:30h
Link de inscrição:
https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpuh&lang=pt-BR
Acompanhe o comunicado de canais para mais datas!
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Dúvidas?
Jacob Fred
[email protected]
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Obrigado!
This document is for IBM and IBM Business Partner use only
© 2012 IBM Corporation
Download