IBM PureSystems SKiLLs – Webcast 2012 Jacob Fred Channel Technical Sales Specialist IBM Systems and Technology Group Tel: +55 11 2322 7089 Mobile: +55 11 97597 9133 Tie Line 740 7089 E-mail: [email protected] This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM PureFlex Systems IBM Flex System Overview This document is for IBM and IBM Business Partner use only xtw280t1 Abril 2012 © 2012 IBM Corporation Agenda IBM Flex System Overview IBM Flex System Enterprise Chassis Overview Nodes Overview I/O Overview Management Overview Power Overview Cooling Overview Rack Overview Soluções Oferecidas This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System Overview Proteção de investimento de avançada tecnologia por diversos anos – Novos processadores, memória, I/O, Storage – Barramentos internos de maior velocidade – I/Os ainda mais rápidos Novo IBM Flex System Manager – Suportado para gerenciar múltiplos IBM Flex System Enterprise Chassis Novos Compute e Storage Systems Novos Scalable Switch Elements (ScSE) e I/O adapters Novo IBM Flex System Enterprise Chassis Management Module Mais eficiência de energia e sistema de resfriamento – Componentes de máxima eficiência – Sofisticado e prático controle do sistema – Compatível com futuras instalações de infraestrutura de Data Centers de alta eficiência This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System Enterprise Chassis - Overview Chassis – 10 U (Rack Units) – 14 baias de Nodes • Suporte para Nodes de tamanhos half e full • Suporte para Nodes duplos • Suporta interconexão de Nodes de expanção – – – – 4 baias de Switch 2 baias de Gerenciamento 6 Power Supplies (2 já inclusas) 10 baias de FANs This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System Enterprise Chassis - Frente Storage node Half node Full node Manager node This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System Enterprise Chassis - Trás 40 mm Fans (2X) 80 mm Fan Packs (8X) IBM Flex System Enterprise Chassis Management Modules (2X) Fan Mux Card (2X) Power Supplies (6X) Scalable Switch Elements (4X) This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System Enterprise Chassis - Baias Shuttle IBM Flex System Enterprise Chassis Node Bay Shelf - Remove para Node Full Wide - Remove dois Shelves para Node Full Wide, Double High This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Compute Nodes - Flex System Manager IBM Flex System Manager (8731) – Appliance de gerenciamento – Node de baia Half-wide – 2 sockets Sandy Bridge-EP • 1 – 8 Cores 2.0GHz 20MB L3 95W – 24 LP DDR3 DIMM Sockets / 1600MT/s • 32GB DDR3 SDRAMS – 8x 4GB – 1x HS 2.5” 1TB SAS HDD – 2x 1.8” 200GB SSDs (RAID 1) – Systems Management Software Stack • Ferramenta de fácil implementação • Ferramentas de Automação de Virtualização • Ferramentas de Migração de Workload This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Compute Nodes - Flex System Manager IBM PureApplication System IBM Flex System Manager (7955) – Appliance de gerenciamento – Node de baia Half-wide – 2 sockets Sandy Bridge-EP • 2 – 8 Cores 2.0GHz 20MB L3 95W – 24 LP DDR3 DIMM Sockets / 1600MT/s • 192GB DDR3 SDRAMS – 24x 8GB – 1x HS 2.5” 1TB SAS HDD – 2x 1.8” 200GB SSDs (RAID 1) – IBM Flex System CN4054 10Gb Virtual Fabric Adapter – IBM Flex System FC3172 2-port 8Gb FC Adapter – Systems Management Software Stack – IBM Workload Deployer This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Compute Nodes - Intel EP IBM Flex System x240 Compute Node – – – – Node de baia Half-wide 2 sockets Sandy Bridge-EP 24 LP DDR3 DIMMs / 1600MT/s 2 HS 2.5” SAS/SATA HDDs or SSDs Frente Trás This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Compute Nodes - POWER 7 IBM Flex System p260 Compute Node – Node de baia Half-wide – 2 sockets POWER 7 • 64-bit Power7 RISC processor 190w • 8 cores – 16 VLP DIMMs DDR3, 1066MT/s, 256GB Max – 2x 2.5 SAS/SATA HDDs ou SSDs IBM Flex System p460 Compute Node – Node de baia Full wide – 4 sockets POWER 7 • 64-bit Power7 RISC processor 190w • 4 / 8 cores – 32 VLP DIMMs DDR3, 1066MT/s, 256GB Max – 2x 2.5 SAS/SATA HDDs ou SSDs This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System V7000 Storage Node IBM Storewize V7000 Storage System – Node de baias Double High / Full Width – 24x 2.5” HDDs ou SSDs – Duas controladoras hot swappable para alta disponibilidade Frente Trás This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Compute Nodes - I/O Ethernet – – – – – IBM Flex System EN2024 4-port 1Gb Ethernet Adapter IBM Flex System EN4054 4-port 10Gb Ethernet Adapter IBM Flex System CN4054 10Gb Virtual Fabric Adapter IBM Flex System CN4054 Virtual Fabric Adapter IBM Flex System EN4132 2-port 10Gb Ethernet Adapter PeX P somente X somente X somente X somente FibreChannel – IBM Flex System FC3172 2-port 8Gb FC Adapter – IBM Flex System FC5022 2-port 16Gb FC Adapter – IBM Flex System FC3052 2-port 8Gb FC Adapter PeX X somente, P futuro P* e X InfiniBand – IBM Flex System IB6132 2-port QDR InfiniBand Adapter – IBM Flex System IB6132 2-port FDR InfiniBand Adapter P somente X somente * Não suportado com AIX This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation I/O - Scalable Switch Element (ScSE) Ethernet I/O – – – – IBM Flex System EN4091 10Gb Ethernet Pass-thru IBM Flex System EN2092 1Gb Ethernet Scalable Switch IBM Flex System EN4093 10Gb Virtual Fabric Scalable Switch FoD Enhancement Licenses FibreChannel I/O – IBM Flex System FC5022 16Gb SAN Scalable Switch – IBM Flex System FC5022 16Gb ESB SAN Scalable Switch – FoD Enhancement Licenses InfiniBand I/O – IBM Flex System IB6131 InfiniBand Switch – FoD Enhancement Licenses This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System Enterprise Chassis Management Module Monitors IBM Flex System Operating Parameters Coleta de inventário Atualização de Firmwares Gerenciamento Low Level de Nodes Configuração L2 de Switch e gerenciamento Interface de usuário Web, CLI, SNMP, CIM Para redundância, utilize dois Enterprise Chassis Management Module This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System - Power Supplies Suporte para até 6 Power Supplies Inclui 2 Power supplies por padrão I2C Managed Element 2500W 208 - 240VAC Input Range 12.2VDC 205A - 225A Output Range 92% eficiência em plena carga Redundância N+M, N+N, N+1 This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Cooling Resfriamento direcionado - Nodes (esq./ dir.), switches Escalável / Expansível 2x FANs de 40mm para ScSEs (Scalable Switches) Até 8 FANs de 80mm para Nodes (4 inclusos) Controle de resfriamento adaptável Acústica avançada e otimizada Fan Multiplexer Card Eficiência líde de indústria Melhoria das características de operacionalidade 40mm Fan This document is for IBM and IBM Business Partner use only 80mm Fan © 2012 IBM Corporation IBM 42U 1100mm Deep Dynamic Rack Novo IBM Rack otimizado – 100mm mais fundo que os racks padrões, ocupando 2 placas de piso elevado – Nova porta com dissipador de calor disponível Trilhos do chassis de fácil instalação Orgnização de cabos aprimorado – Ampla saída de cabos – Pistas de cabos da frente para trás 6 encaixes laterais de PDU Cable Egress Rear PDU Access 6x Cable Channels Strip PDU Support 4X Cable Tie Points Cable Egress Thermal Sealing Plane (front EIA flange) Cable Channels Cable Egress Outrigger Front of Rack Rear of Rack This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM PureFlex Config mínima Hardware Rack Chassis Power Supplies / Fans Ethernet Switch TOR Switch FC Switch FSM HW V7000 HW INode Mezz cards Software V7000 SW FSM SW OS PowerVM (Power only) PowerSC (Power only) Smart Cloud Entry Services SWMA HWMA MTS Lab Services Express Standard Enterprise Incluso Incluso 2/4 BNT 10GB n/a QLogic 8GB Incluso Incluso com Drives P260 ou x FC, Enet Incluso Incluso 4/6 BNT 10GB n/a QLogic 8GB (2) Incluso Incluso com Drives P260 / p460 ou x FC(2), Enet Incluso Incluso 6/8 BNT 10GB (2) 2 Eth,2 FC – somente Power QLogic 8GB (2) Incluso Incluso com Drives Dois p460 ou Dois x FC(2), Enet (2) Incluso Incluso Incluso Incluso Incluso opcional Incluso Incluso Incluso Incluso Incluso Incluso / possível deselecionar Incluso Incluso Incluso Incluso Incluso Incluso / possível deselecionar 1 ano 9x5 3 anos 9x5 default 1 ano 9x5 selectable 3 ano 9x5 3 anos microcode (1) WSU 24x7 Account Advocate 9x5 5 dias 3 anos 9x5 3 ano 9x5 3 anos microcode (1) 3 dias This document is for IBM and IBM Business Partner use only 3 anos 9x5 3 anos microcode (2) WSU 24x7 Account Advocate 24x7 7 dias © 2012 IBM Corporation IBM PureFlex IBM PUREFLEX SYSTEM FEATURE CODE EXPRESS STANDARD ENTERPRISE DESCRIPTION 1 1 1 1 1 2 #3593 IBM FLEX System EN4093 10 Gb Virtual Fabric Scalable Switch 2 #3596 Port Upgrade1 for #3593 2 #3597 Port Upgrade 2 for #3593 Flex System Enterprise Chassis (7893-92X), with the following features: 1 2 2 #3595 IBM Flex System FC3171 8 Gb SAN Switch 2 4 4 #3282 10 GbE SFP+ Transceiver 2 4 8 #3286 8 GB SFP+ Transceiver 5 5 6 #EB29 1000Base-T SFP RJ45 Transceiver 1 1 1 #9039 Base CME 1 1 1 #3592 Redundant CME 2 2 2 #9059 Base Power Module (2X) 2 4 #3590 Redundant Power Module 2 4 6 #4558 Power Cord (2.5M) to PDU/UPS 1 1 1 #9038 Base Fans (4X) 1 2 #7805 Additional Fans (2X) 2 2 #1111 CAT5E Ethernet Cable, 3M Blue 4 #ECB4 10 GbE SFP+ Copper DAC Cable,1 M 1 #EFM1 Open Fabric Manager 2 1 1 This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM PureFlex IBM PUREFLEX SYSTEM FEATURE CODE EXPRESS STANDARD ENTERPRISE DESCRIPTION 1 1 1 1 1 1 #EB31 Platform Manager S/W Bundle 4 4 4 #EM09 32 GB Memory 2 2 2 #1771 IBM 200 GB 1.8" SATA SSD 1 1 1 #3767 1TB 7.2K RPM 2.5" SATA Disk Drive 1 1 2 1 1 1 Flex System Manager (FSM) (7955-01M), with the following features: Flex System x240 Compute Node (7863-10X), with the following features: #EN20 or Compute Node with 10Gb Virtual Fabric or 1 1 1 #EN21 Compute Node without 10Gb Virtual Fabric 1 1 1 #EM05 or #EEM2 1 1 1 #1759 IBM Flex System CN4054 10 Gb Virtual Fabric Adapter (Not required with #EN20) 1 1 1 #1764 IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter 1 1 1 #EBK2 IBM Flex System x240 USB Enablement Kit 1 1 1 #EBK3 2 GB USB Hypervisor Key (VMWare 5.0) 4 GB minimum memory This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM PureFlex IBM PUREFLEX SYSTEM FEATURE CODE EXPRESS STANDARD ENTERPRISE DESCRIPTION 1 1 1 1 1 1 #0010 Storwize V7000 S/W Preload 2 4 4 #5305 1M or 5M Fiber Optic Cable 8 8 8 #3206 600 GB 2.5-inch 20k HDD 2 2 4 #3512 or #3214 2 2 2 #6008 Cache 8 GB 1 1 1 #9730 Power Cord - PDU Connection 2 2 2 #9801 AC Power Supply 1 1 1 2 2 2 #7189 or #7196 Optional PDUs 1 1 1 #EC02 or #EC05 Rack Rear Door or RDHX 1 1 1 #EC03 Side Doors 1 1 1 #EC06 Rack Front Door Storwize V7000 Disk System (2076-124), with the following features: 200 or 400 GB 2.5-inch SSD Flex System Enterprise Rack (7953-94X), with the following features: This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM SmartCloud Entry Self Service Private Cloud Portal Permite o cliente: – – – – – Provisionar (implantação) e de-provisionar servidores virtuais Elaboração e clone de workloads virtualizados Tirar workloads snapshots Inicializando e desligando servidores virtuais como parte de um workload Redimensionando servidores virtuais existentes Estes e muitos outros features estão inclusos nesta versão do IBM SmartCloud Entry https://www.ibm.com/developerworks/mydeveloperworks/wikis/home/wiki/W21ed5ba0f4a9_46f4_9626_24cbbb86fbb9?lang=en This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM PureApplication System - High Performance Model Cable ingress / egress Storage Controller IBM Storwize V7000 Disk System 4 x 400 GB SAS SSD per enclosure 20 x 600 GB SAS HDD per enclosure BNT 64 PT Enet SW BNT 64 PT Enet SW V 7000 Expansion V 7000 Controller V 7000 Expansion V 7000 Controller Intel Compute Intel Compute Intel Compute Intel Compute New Chassis Common Management Module 2x 10Gb Ethernet Switch 2x 16 Gb FC Switch Intel Compute Intel Compute Intel Compute Intel Compute PDU PDU Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute IBM PureApplication System Management Node IBM Workload Deployer Intel Compute Intel Compute MGMT MGMT Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute Intel Compute VM Management Node Intel Compute Intel Compute Intel Compute Intel Compute MGMT http://www-01.ibm.com/software/webservers/workload-deployer/ MGMT Cable ingress / egress PDU PDU Intel Compute Intel Compute 42 U 41 U 40 U 39 U 38 U 37 U 36 U 35 U 34 U 33 U 32 U 31 U 30 U 29 U 28 U 27 U 26 U 25 U 24 U 23 U 22 U 21 U 20 U 19 U 18 U 17 U 16 U 15 U 14 U 13 U 12 U 11 U 10 U 9 U 8 U 7 U 6 U 5 U 4 U 3 U 2 U 1 U This document is for IBM and IBM Business Partner use only Top of Rack Switches BLADE Network Technologies Top of Rack Switches Customer Data Center & Rack-to-rack communications V7000 Disk Expansion Per enclosure: 4 x 400 GB SAS SSD 20 x 600 GB SAS HDD Intel Compute 2.6 GHz 8C Intel processor, 110 W 256 KB L2 per core 4 MB eDRAM L3 per core 2x 4 Port 10 GbE 2x 2 Port 8 Gb/s FC Overall Power ~30 KW Cores 608 Cores Memory SSD Storage 9.7 TB 6.4 TB (unformatted) 48.0 TB (unformatted) © 2012 IBM Corporation IBM PureApplication – Soluções Oferecidas Small Part #5 (Part 1) Enet SW 64 PT Enet SW 64 PT V7000 Expansion V7000 Expansion V7000 Controller V7000 Controller P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Cores/Threads PVUs Memory (GB) Raw SSD/HDD (TB) Usable SSD/HDD (TB) PDU L Volt PDU H Volt Power (Max) Application Services 96/384 9600 1536 6.4 / 48 4.8 / 38.4 4x60A 3ph 4x32A 3ph 10.6 kW Included 42U 41U 40U 39U 38U 37U 36U 35U 34U 33U 32U 31U 30U 29U 28U 27U 26U 25U 24U 23U 22U 21U 20U 19U 18U 17U 16U 15U 14U 13U 12U 11U 10U 9U 8U 7U 6U 5U 4U 3U 2U 1U Medium (Part 2) Enet SW 64 PT Enet SW 64 PT V7000 Expansion V7000 Expansion V7000 Controller V7000 Controller P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Part #6 42U 41U 40U 39U 38U 37U 36U 35U 34U 33U 32U 31U 30U 29U 28U 27U 26U 25U 24U 23U 22U 21U 20U 19U 18U 17U 16U 15U 14U 13U 12U 11U 10U 9U 8U 7U 6U 5U 4U 3U 2U 1U 192/768 19200 3072 6.4 / 48 4.8 / 38.4 4x60A 3ph 4x32A 3ph 14.4 kW Included This document is for IBM and IBM Business Partner use only Large (Part 3) Part #7 Enet SW 64 PT Enet SW 64 PT V7000 Expansion V7000 Expansion V7000 Controller V7000 Controller P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S P7 FW Firebird 4S Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S P7 FW Firebird 4S 384/1536 38400 6144 6.4 / 48 4.8 / 38.4 4x60A 3ph 4x32A 3ph 22.2 kW Included 42U 41U 40U 39U 38U 37U 36U 35U 34U 33U 32U 31U 30U 29U 28U 27U 26U 25U 24U 23U 22U 21U 20U 19U 18U 17U 16U 15U 14U 13U 12U 11U 10U 9U 8U 7U 6U 5U 4U 3U 2U 1U Enet SW 64 PT Enet SW 64 PT V7000 Expansion V7000 Expansion V7000 Controller V7000 Controller P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes Mgmt Mgmt P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes P7 FW Firebird 4S Compute Nodes 42U 41U 40U 39U 38U 37U 36U 35U 34U 33U 32U 31U 30U 29U 28U 27U 26U 25U 24U 23U 22U 21U 20U 19U 18U 17U 16U 15U 14U 13U 12U 11U 10U 9U 8U 7U 6U 5U 4U 3U 2U 1U 608/2432 60800 9728 6.4 / 48 4.8 / 38.4 4x60A 3ph 4x32A 3ph 31.2 KW Included © 2012 IBM Corporation This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation IBM Flex System – Tour Virtual • Enterprise Chassis http://www03.ibm.com/systems/data/flash/flex/virtualtours/chassis/index.html • x240 Compute node http://www03.ibm.com/systems/data/flash/flex/virtualtours/compute-nodes/x240/index.html • x440 Compute node http://www03.ibm.com/systems/data/flash/flex/virtualtours/compute-nodes/x440/index.html • p460 Compute node http://www03.ibm.com/systems/data/flash/flex/virtualtours/compute-nodes/p460/index.html This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation PureSystems - Webcasts Brasil 2H-2012 Foco na certificação técnica Skill 1 - IBM PureFlex Systems - Posicionamento (Técnico/Comercial) Dia: 16/08/2012 Horário: das 10:00h às 11:30h Link de inscrição: https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpru&lang=pt-BR Skill 2 - IBM PureFlex Systems - IBM Flex System Enterprise Chassis Overview (Técnico) Dia: 23/08/2012 Horário: das 10:00h às 11:30h Link de inscrição: https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpta&lang=pt-BR Skill 2 - IBM PureFlex Systems - IBM Flex System Nodes Overview Dia: 30/08/2012 Horário: das 10:00h às 11:30h Link de inscrição: https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpuh&lang=pt-BR Acompanhe o comunicado de canais para mais datas! This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Dúvidas? Jacob Fred [email protected] This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation Obrigado! This document is for IBM and IBM Business Partner use only © 2012 IBM Corporation